VAX Multi-Door Controller

Quick Start Guide

www.vicon-security.com

Door Installation Example

Networking Example

Part Number

VAX-MDK-2
VAX-MDK-4
VAX-MDK-6
VAX-MDK-8

VAX-EXP-2D

1
2

3
4

Part Number

PRS-1IO
PRS-2IO
PRS-3IO
PRS-4IO

VAX-IO-EXP8PCB

1
2

3
4

PRS-5IO
PRS-6IO
PRS-7IO
PRS-8IO

5
6

7

8

PRS-MASTER x 1

CONTROLLER

2P Connector x 1

3P Strip(s)

Package Contents

Battery Cable x 1

Cable Requirements

1 2 3 4 5 6 7 8

White/Orange
Orange

White/Green
Blue

1
2

White/Blue
Green

3
4
5
6

White/Brown
Brown

7
8

T568B (TIA/EIA568B) Wiring

Network Cable***

100 m (328’)

twisted pair, 4 pairs

Cat5 100BASE-T or better

Door Strike Cable

152 m (500’)

2 conductor stranded 18 AWG

Belden 9740 or equivalent*

Output Cable

152 m (500’)

2 conductor stranded 22 AWG

Belden 8740 or equivalent*

Input Cable

152 m (500’)

2 conductor stranded 22 AWG,

shielded

Belden 8723 or equivalent*

RS-485 Cable

with Power

600 m (2000’)

4 conductor stranded, twisted pair, 

2 pairs, 22 ~ 16 AWG**, shielded

Belden 9402 or equivalent*

Reader Cable

152 m (500’)

6 conductor stranded not twisted,

24 AWG or thicker,

100% overall shielded

Belden 9537 or equivalent

Name

Cable Type

Code

Maximum

Distance

* Unless otherwise specified by manufacturer.

** Varies by current consumption of the other side.

*** Recommended the following T568B wiring for both ends.

VICON INDUSTRIES INC.

Vicon part number: 8009-8274-50-01  Rev. 618

UL 294/S319/Safety EN 60950-1, A2 Compliance Notices

This product complies with the following UL294 Access Control Performance Levels when installed as part of the Listed VAX  system : 

Endurance Level IV (100,000c) Line Security Level I
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA C22.1, Canadian Electrical Code, 

Part I, Safety Standard for Electrical Installations, Part I, local codes, and the authorities having jurisdiction.  All interconnecting 

devices must be UL Listed, low-voltage Class 2 power limited. The minimum permissible wire size to be used shall not be less than 

26 AWG (0.24 mm2).

Products have been evaluated for “Indoor Use” only, and to be installed within the “protected” or “restricted” area.  This product is 

not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70.  Products are not intended to be 

installed or mounted in air-handling spaces.  Products are intended to be installed by manufacturer trained service installers only.

All recommended connected peripherals such as power supplies, UPS/battery backups, PoE switches, electrified strikes, readers 

require to be UL Listed.

Please refer to the VAX UL Reference document for more comprehensive information available downloadable from our website.  

Hard copy of the VAX UL Reference Manual document is available; please call

a.  To shut down the unit/controller cards, disconnect the network cable from the unit.

b.  Only a qualified person should install and handle the system.

c.  The unit gets up to 48 VDC from any PoE switch it is used with.

d.  The VAX units are not connected to the electric line.

e.  Grounding is not required.

f.   A nylon cable gland needs to be installed in the access hole where the cables enter the case.

g.  Units powered by PoE must use a detachable network cable.

h.  This is an indoor unit with an operating temperature range of 32° – 122° F (0° – 50° C).

Summary of Contents for VAX-MDK-2

Page 1: ... EN 60950 1 A2 Compliance Notices This product complies with the following UL294 Access Control Performance Levels when installed as part of the Listed VAX system Endurance Level IV 100 000c Line Security Level I Wiring methods shall be in accordance with the National Electrical Code ANSI NFPA70 CSA C22 1 Canadian Electrical Code Part I Safety Standard for Electrical Installations Part I local cod...

Page 2: ...hold Select Input Test menu Enter keys LCD displays current input states D Digital S Supervised o open c closed 2 2 4 1 1 Input Test Reader Test 1 2 3 4 5 6 7 8 DoSoScDoDoDo___ Note Reader Test Get in Setup Menu Edit Mode by pressing Enter Key and hold Select Reader Test menu Enter keys Scan a card or press numbers and keypad reader only LCD shows the data infomation 2 2 Select board type and addr...

Page 3: ... Enter Exit menu Esc Setup Menu Edit Mode Get in Press and hold Enter beeps after 2 sec Enter password Get out Esc Move cursor Up Right Down Left Select menu Enter Exit menu Esc Toggle cursor Enter White blink move Black blink edit Input Types Specification Digital Input States 1 1 Supervised Input States 2 2 1 2 3 Input1 Common 1 2 3 Input1 Common On 1 2 3 Input1 Common Off 1 2 3 Input1 Common Sh...

Page 4: ... data D7 Power D2 Server log on off state Blink Incorrect address D3 Input Changed LEDs D11 Relay1 on D12 Relay2 on D13 Relay3 on D14 Relay5 on D15 Relay6 on D16 Relay7 on D17 Relay7 on D18 Relay8 on Connectors P11 Relay1 dry P14 Relay4 dry P15 Relay5 dry P16 Relay6 dry P17 Relay7 dry P18 Relay8 dry P9 Power comm data P1 Input1 Common Input2 P12 Relay2 dry P13 Relay3 dry P10 DC 12V out max 200mA P...

Page 5: ...liance Notices This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the...

Reviews: