HARTMANN
A
B
C
D
K
R1
R2
G
H
I
A
VAX-MDK
J
B
Electric Strike
C
Auto Door Opener
D
External Buzzer
G
Handicap Open
H
Door Contact
J
Auto Door Open
K
Motion Sensor
R1
Inside Reader
R2
Outside Reader
I
Emergency Alarm
VAX-MDK
CONTROLLER
Router
PC
Controller
Outputs
Inputs
5
8
0
2
1
4
7
9
6
3
HAR
TMANN
LAN
INTERNET
VAX Multi-Door Controller
Quick Start Guide
www.vicon-security.com
Door Installation Example
Networking Example
Part Number
VAX-MDK-2
VAX-MDK-4
VAX-MDK-6
VAX-MDK-8
VAX-EXP-2D
1
2
3
4
Part Number
PRS-1IO
PRS-2IO
PRS-3IO
PRS-4IO
VAX-IO-EXP8PCB
1
2
3
4
PRS-5IO
PRS-6IO
PRS-7IO
PRS-8IO
5
6
7
8
PRS-MASTER x 1
CONTROLLER
2P Connector x 1
3P Strip(s)
Package Contents
Battery Cable x 1
Cable Requirements
1 2 3 4 5 6 7 8
White/Orange
Orange
White/Green
Blue
1
2
White/Blue
Green
3
4
5
6
White/Brown
Brown
7
8
T568B (TIA/EIA568B) Wiring
Network Cable***
100 m (328’)
twisted pair, 4 pairs
Cat5 100BASE-T or better
Door Strike Cable
152 m (500’)
2 conductor stranded 18 AWG
Belden 9740 or equivalent*
Output Cable
152 m (500’)
2 conductor stranded 22 AWG
Belden 8740 or equivalent*
Input Cable
152 m (500’)
2 conductor stranded 22 AWG,
shielded
Belden 8723 or equivalent*
RS-485 Cable
with Power
600 m (2000’)
4 conductor stranded, twisted pair,
2 pairs, 22 ~ 16 AWG**, shielded
Belden 9402 or equivalent*
Reader Cable
152 m (500’)
6 conductor stranded not twisted,
24 AWG or thicker,
100% overall shielded
Belden 9537 or equivalent
Name
Cable Type
Code
Maximum
Distance
* Unless otherwise specified by manufacturer.
** Varies by current consumption of the other side.
*** Recommended the following T568B wiring for both ends.
VICON INDUSTRIES INC.
Vicon part number: 8009-8274-50-01 Rev. 618
UL 294/S319/Safety EN 60950-1, A2 Compliance Notices
This product complies with the following UL294 Access Control Performance Levels when installed as part of the Listed VAX system :
Endurance Level IV (100,000c) Line Security Level I
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA C22.1, Canadian Electrical Code,
Part I, Safety Standard for Electrical Installations, Part I, local codes, and the authorities having jurisdiction. All interconnecting
devices must be UL Listed, low-voltage Class 2 power limited. The minimum permissible wire size to be used shall not be less than
26 AWG (0.24 mm2).
Products have been evaluated for “Indoor Use” only, and to be installed within the “protected” or “restricted” area. This product is
not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70. Products are not intended to be
installed or mounted in air-handling spaces. Products are intended to be installed by manufacturer trained service installers only.
All recommended connected peripherals such as power supplies, UPS/battery backups, PoE switches, electrified strikes, readers
require to be UL Listed.
Please refer to the VAX UL Reference document for more comprehensive information available downloadable from our website.
Hard copy of the VAX UL Reference Manual document is available; please call
a. To shut down the unit/controller cards, disconnect the network cable from the unit.
b. Only a qualified person should install and handle the system.
c. The unit gets up to 48 VDC from any PoE switch it is used with.
d. The VAX units are not connected to the electric line.
e. Grounding is not required.
f. A nylon cable gland needs to be installed in the access hole where the cables enter the case.
g. Units powered by PoE must use a detachable network cable.
h. This is an indoor unit with an operating temperature range of 32° – 122° F (0° – 50° C).