How to Do the Waterproof Installation
The following installation procedure assures the camera to be water-resistant, even in
environments where the camera can easily be flooded by pouring rain.
Important for the installation:
The protection of the cabling must be done by a proper flex conduit.
The size of the flex conduit that matches the conduit gland is is
3/8”
(trade size) (customer-supplied; not included in the package).
Insert the Ethernet cable through the flex conduit together
with RJ-45 connector. As an alternative, connect the RJ-45
connector by crimping after pushing the cable through the
conduit.
Disassemble the conduit gland.
Slide the
clamping nut
around flex conduit approximately
4-8 in. (100-200 mm) away from the top. Fit the
sealing
insert
(made of rubber) to the top of the flex conduit.
Select which of the 2 holes is going to be used to connect the flex conduit, the hole on the side
or the hole on the bottom. Remember to seal off the hole not used with the metal
patch
(included in the camera accessories).
Using the side hole
Using the bottom hole