34
People Counting
1.
Click Setup > Intelligent > Smart Settings. Choose People Counting and then click
.
2.
Select Enable Passenger Flow Detection. Select a detection mode, set report interval and sensitivity.
3.
Click Draw Detection Area, and then draw a detection area on the preview window on the left, e.g., a
square.
4.
Click Draw Entrance Direction, and then draw the direction on the preview window on the left. The
direction is usually vertical or sloping.
5.
Set Max. Size and Min. Size under Filter by Object Size. Only objects within the size range will be
counted; others will be filtered and not counted. The maximum width or height must be greater than
the minimum width or height.
6.
Set the alarm-triggered actions and arming schedule as required. For the detailed steps, see the
descriptions of alarm-triggered actions in
Configuring Motion Detection Alarm
7.
To reset counting results, click Clear Counting Result.
8.
Click Save.
Advanced Settings
Advanced settings include photo clarity and detection mode for intelligent functions.
Photo parameters
Set clarity of snapshots.
1.
Click Setup > Intelligent > Advanced Settings. Click Photo parameters tab.