background image

Thank you for your purchase of this product. Before operating the product, please
read this instruction manual carefully to ensure proper use of the product.  Please
store this instruction manual in a safe place for future reference.

CONTENTS

PRESIDENT’S LETTER ................................................................................. EG-1
FCC NOTICE ................................................................................................ EG-1
FEATURES ................................................................................................... EG-2
SAFETY PRECAUTIONS ............................................................................... EG-2
PARTS DESCRIPTION .................................................................................. EG-3
INSTALLATION & ADJUSTMENT .................................................................. EG-4
SPECIFICATIONS ......................................................................................... EG-8
SHIPPING INSTRUCTIONS .......................................................................... EG-9
REFERENCE ................................................................................................. EG-9
VICON STANDARD EQUIPMENT WARRANTY ............................................ EG-10

FEATURES

Integrated  vari-focal lens allows for versatile application and easy installation.

Manual pan/tilt/rotation mechanism.

Accepts either 12VDC or 24VAC power input. (Automatic switching)

SAFETY PRECAUTIONS

The installation should be made by qualified service personnel or system installers
and should conform to all local codes.

This symbol indicates that there is a possibility of death or damage to operator or
others.

To prevent fire or electric shock, Do not expose this product to rain or moisture.

This symbol indicates that there is a possibility of injury or damage to equipment.

(1) Use only 24V AC power supply marked class 2 or +12V DC regulated power

supply marked class 2.

(2) To prevent fire or electrical shock, UL listed class 2 wiring should be used for the

12V DC or 24V AC input terminal.

(3) Be sure to connect each lead to the appropriate terminal. Wrong connection

may cause malfunction and /or damage to the video camera.

(4) Do not attempt to aim the camera at the sun or other extremely bright objects

that cause smear to appear irrespective of whether the camera is operating or
not. This can damage the CCD (Charge Coupled Device).

(5) Do not place the camera in the following locations.

 Locations subjected to extremely high or low temperatures.

(Operating temperature range: -10°C to +50°C {14°F to 122°F})
(Storage temperature range: -20°C to +60°C {-4°F to 140°F})

 Locations subjected to high level of humidity and dust.

(Operating humidity range: max 85% {No condensation})
(Storage humidity range: max 95% {No condensation})

 Locations where there are large amounts of water vapor and steam.

(6) Ensure the location selected is sufficiently strong enough to support the weight

of the camera and is free from vibration.

(7) When this camera is installed near equipment that emits a strong electromag-

netic field, some irregularity such as noise on the monitor screen may happen.

(8) Be sure to use screws suitable for the type of material to which the camera is

being mounted.

(9) Do not allow the camera to be subjected to strong impacts or shocks. The cam-

era could be damaged by improper handling or storage.

(10) Never attempt to disassemble or modify the camera.
(11) If an abnormality should occur, immediately turn off the power and consult your

dealer.

This device complies with Part 15 of the FCC Rules. Operation is subject to the follow-
ing two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept
any interference received, including interference that may cause undesired operation.

EG-2

(EG)VICONーV3FCD̲1120

03.11.26, 11:37 AM

Page 3

Adobe PageMaker 6.5J/PPC

Summary of Contents for V3FD Series

Page 1: ...be used for this purpose Copyright 2003 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industrie...

Page 2: ...C rules which are designed to provide reasonable protection against such interference in a commercial installation How ever there is no guarantee that interference will not occur in a particular insta...

Page 3: ...to aim the camera at the sun or other extremely bright objects that cause smear to appear irrespective of whether the camera is operating or not This can damage the CCD Charge Coupled Device 5 Do not...

Page 4: ...Removal and Attachment Coaxial video cable Coaxial video cable Service monitor cable DIP switch DC iris adjustment volume To remove the dome cover pull lightly To attach it insert and press the cover...

Page 5: ...3 Running cable along the ceiling or wall surface Back of camera body Wall Press open the perforated section and run the cables through Connecting the Cables Please refer to the diagrams below Connec...

Page 6: ...tion Camera body moves in three ways Pan Tilt and Rotate Adjust the direction so that the lens is aiming at the target Adjusting the View Angle Focus and Iris Use the lever to adjust the view angle an...

Page 7: ...strong light is in the 3 Compensation back ground BLC OFF Normal position 4 Synchronization INT Internal synchronization mode Mode L L Line lock mode 24VAC 60Hz only 7 DIP Switch Set Up Set according...

Page 8: ...lighting conditions If necessary turn the volume to adjust the DC iris level Attention In case of Black White models set AGC DIP switch to OFF while adjusting DC iris level Completing the Adjustment...

Page 9: ...0IRE 0 75 lx S N Ratio More than 50 dB AGC gain minimum Characteristic 0 45 Sync System INT L L Electric Shutter NTSC 1 60 Sec Fixed Flickerless OFF 1 100 Sec Fixed Flickerless ON EIA 1 60 Sec Fixed W...

Page 10: ...ed center conductor Never exceed the manufacturers minimum bend radius specification Use cellular foam polyethylene dielectric except where heavy moisture exists For moisture conditions use solid poly...

Page 11: ...licy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been ta...

Page 12: ...m PO15 5TX 770 449 0499 800 824 8479 United Kingdom Fax 770 446 8779 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Vicon China Planet II Unit Unit 5 17 F Metropole Square Leuvensesteenweg 542...

Reviews: