background image

18 

3.

 

Change User Password 

Click 

  button in the list and  the Edit User Information dialog 

box will pop up. 

 

Figure 3-46 

 

Input the old password, enter your desired new password twice (once 
to confirm) and then click “OK” button; a prompt pops up as follows: 

 

Figure 3-47 Edit Password 

 

3.11 System Log 

Click  “Log”  button  on the navigation bar  to  enter the system log 
interface as shown below: 

Figure 3-48 

 

Up to 30 logs can display on one page. Users can turn over the page 
by clicking the arrows at the bottom or skip to the designated page 
by clicking “Goto”. To remove a log, click “Delete logs”: a prompt 
will display: click “Yes” to clear logs. 
 
 
 

Chapter IV PTZ Control and Call Up 

4.1 PTZ Control 

In Live view interface, click “PTZ control” tab to expand the PTZ 
control interface as shown below:   

 

Figure 4-1 PTZ control interface 

 

In the interface, users can perform PTZ control, iris adjustment, 
focus/zoom adjustment, and also set the pan and tilt speed.   
Press the direction keys, the dome will start to move. Release the key 
to stop movement.   

  buttons are used to adjust iris. 

The  left 

  button is used  to  narrow  the iris. The image will 

become dim when this button is pressed.   

The  right 

  button is used to enlarge  the iris. The image will 

become bright when this button is pressed. 

  buttons are used to adjust zoom. 

Press 

  button to zoom out to get the telephoto-images. 

Press 

  button to zoom in to get the close-images. 

  buttons are used to adjust focus. 

Press 

  button for wide focus, and press 

  button for 

telephoto focus. 

The pan and tilt speed can be set in this interface, with 8 different 
level options. The higher the level is, the faster the dome moves. 

 

 

Summary of Contents for Surveyor MKII Series XX282-40-01

Page 1: ...d in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc Tel 631 952 2288 Fax 631 951 2288 Toll Free 8...

Page 2: ...emarks that may appear belong to their respective proprietors FCC Warning The Surveyor MKII HD Network Domes comply with the FCC rules Operation is subject to the following two conditions This device...

Page 3: ...from ground and entrance Refer to qualified personnel for all service matters Save product packaging to ensure availability of proper shipping containers for future transportation The power supply of...

Page 4: ...8 3 3 7 IGMP 8 3 3 8 SIP 8 3 3 9 MDA 9 3 3 10 DDNS Setting 9 3 3 11 UPnP Setting 9 3 3 12 IP Filter Setting 9 3 4 Camera Settings 10 3 5 Audio Video 11 3 5 1 Video Settings 11 3 5 2 OSD 11 3 5 3 Moti...

Page 5: ...og function IP67 environmental rating with built in heater and air cycle system and freeze proof 1 3 Product Specifications Lens Optical Zoom 30X Aperture Focal Length F1 4 F4 6 f 4 4 132 0mm Angle of...

Page 6: ...Chapter II IE Browser Setting The user must set the IE browser and system before attempting to view the video When setting the IE browser note that the dome supports IE browser versions of Internet Ex...

Page 7: ...ning the software users should use the default admin username and password The default User is ADMIN uppercase case sensitive Password 1234 Input the correct user name and password and then press OK t...

Page 8: ...ion and privacy mask functions are enabled in the Audio video interface Refer to the sections 3 5 3 and 3 5 4 for details In the Live view interface users can perform PTZ control call up PTZ functions...

Page 9: ...ed Note Available only for the admin Factory Settings Surveyor MKII HD series domes provides an online reset function which greatly facilitates reset adjustment Click Maintain current IP so the IP add...

Page 10: ...e turned On or Off as required 3 3 2 FTP Figure 3 11 FTP settings Surveyor MKII HD series domes support the function of alarm associated FTP image unloading automatically capture images when alarm occ...

Page 11: ...ethod and enter the user name and password 3 3 6 QoS Figure 3 15 QoS settings Users can set the network service quality in the QoS setting interface There are 4 network Qos modes to be selected 1 Norm...

Page 12: ...ame System DDNS can enable constant synchronization of the host name and the dynamic IP address Users only need to input the dynamic domain name to connect to a network camera instead of memorizing th...

Page 13: ...ue light AGC can be set Exposure Parameter settings are shown below Mode Set exposure mode Auto low Auto medium Auto high Auto D N Shutter Exposure Level In Shutter mode set the Level and select from...

Page 14: ...CBR constant bit rate and Dynamic options With variable bit rate the system can automatically adjust the bandwidth of the images per the complexity of the images In practical use the complexity of the...

Page 15: ...OFF and then click the button Save 3 5 3 Motion Detection Figure 3 28 Motion detection settings Motion detection function is supported Up to 4 motion zones can be configured If the zone number is alre...

Page 16: ...t position 7 Press Delete button to delete the selected preset 8 Press Delete all button to delete all the presets 3 6 2 Scan Select Scan tab and the interface is shown as follows Figure 3 32 Scan 1 S...

Page 17: ...eriod of time In the setting interface users can set return time action No 1 32 preset No 1 4 Auto tours and No 1 4 Scan are options and decide whether to return to the position before powering off 3...

Page 18: ...ngle normal far vision 3 7 Schedules Click Schedule on the left navigation bar to display the Schedules interface shown below Figure 3 38 Time function In Mode setting the Act mode status and effectiv...

Page 19: ...e can be set Users can select the alarm period For example if Sunday is checked then on each Sunday the alarm settings will be in effect in the set time if Everyday is selected then the alarm settings...

Page 20: ...s operators or viewers and change their passwords The user name ADMIN cannot be changed but it is recommended to change the ADMIN password for increased security The system supports up to 8 users The...

Page 21: ...TZ control tab to expand the PTZ control interface as shown below Figure 4 1 PTZ control interface In the interface users can perform PTZ control iris adjustment focus zoom adjustment and also set the...

Page 22: ...ere of the selected area with the mouse the target area will be centered on the video display screen Figure 4 4 Dragging the frame with mouse Figure 4 5 Selected area zoom and centered When the option...

Page 23: ...y interface right click the window and select Snapshot in the popped up menu then the current image can be saved to the local PC For instruction about the snapshot saving path please refer to the sect...

Page 24: ...V1 0 1511...

Page 25: ...VICON INDUSTRIES INC For office locations visit the website www vicon security com...

Reviews: