Vicon SMS Enterprise Installation & Operation Manual Download Page 6

3

 

                                      Inside the drive door on the Enterprise Ultra 

4.  For the Enterprise (1U), press the power switch on the back panel to enable power to the 

power supply. Then press the power switch on the front panel to power on. See the diagrams 
below. 

         

I

0

Power Switch

(This switch enables power 

to the power supply.)

 

                              The back panel of the Enterprise Network Controller, 1U rack mount. 

 

    

PWR

TEMP HDD

FAN

System

Reset

Alarm
Reset

Power

Power Switch

(This switch powers 

up the unit.)

 

                              The front panel of the Enterprise Controller, 1U rack mount. 

 

Configuring IP Settings 

 

Configuring IP settings through the web interface 

1.  Open your browser and in the address field enter 192.168.0.250. This is the Network 

Controller default IP address. Press the Enter key. The Init Mode page should now display 
allowing you to set network IP settings. 

NOTE

: If the Init Mode page does not display select 

Setup : Site Settings : Network 

Controller

 and click the link in the 

Initmode Settings

 section. 

2.  You can edit any of the settings on this page. 

NOTE

: If you change the IP address of the Network Controller be sure to take note of the 

new address as you will need it to log in later. 

3. In 

the 

Initmode Settings

 section select 

No

 from the drop-down. This ensures that Init mode 

will not redisplay when you reboot. You can redisplay the Init mode page at any time from the 
security application by selecting 

Setup : Site Settings : Network Controller 

and click the 

link in the

 Initmode Settings 

section

.

 

4. Click 

Save

5. Click 

Reboot

. The application may take several minutes to shut down and restart. You will 

hear two beeps when it shuts down, followed by a single beep when it restarts. 

6.  Open a browser window on a computer connected to the router and in the Address box, enter 

the IP address that you set for the Network Controller. 

7.  On the page that appears, the 

Activation Key

 and 

Product Key

 boxes should contain the 

correct keys for your system. If these boxes are empty, you will need to enter this information 

Summary of Contents for SMS Enterprise

Page 1: ...precisely as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2009 Vicon Industries Inc All rights reserved Product specifications subject to change without notice VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Ho...

Page 2: ......

Page 3: ...in tight spaces where they will be pinched or used to bear weight Allow some slack in the cord where it enters the unit 12 Lightning Disconnect the product from its power source and cable system when possible to prevent damage due to lightning and power line surges 13 Power Lines Do not locate outside cables over power or utility lines where they can fall and make direct contact Contact with power...

Page 4: ...rise Network Controller 2 Configuring IP Settings 3 Logging in to your Network Controller 4 Connecting Nodes and Configuring System Resources 4 Specifications 6 Front Panel LEDs 6 Reset Switches and Drive Lights 7 Hard Drives 8 Migrating from a Basic Network Controller to an Enterprise Network Controller 9 ...

Page 5: ...images below 2 Connect the network cable to the network connector on the back of the Enterprise or Enterprise Ultra Network Controller Be sure the place the cable in the correct connector as shown below The back panel of the Enterprise Network Controller 1U rack mount The back panel of the Enterprise Ultra Network Controller 2U rack mount 3 For the Enterprise Ultra 2U open the drive door on the fr...

Page 6: ...Network Controller and click the link in the Initmode Settings section 2 You can edit any of the settings on this page NOTE If you change the IP address of the Network Controller be sure to take note of the new address as you will need it to log in later 3 In the Initmode Settings section select No from the drop down This ensures that Init mode will not redisplay when you reboot You can redisplay ...

Page 7: ...the screen 6 Beneath the Current value next to the New value prompt enter the new value for this setting and press Enter 7 Use the arrow keys to move the highlight down to Save changes and press Enter The IP setting changes that you have made are now saved to the Network Controller 8 Repeat steps 5 through 8 to make any further changes to the Network Controller IP settings 9 Use the arrow keys to ...

Page 8: ...cedure and ensure that all nodes are enabled 10 If some nodes still will not connect it may be necessary to adjust port forwarding on routers and gateways to allow the nodes on different subnets to communicate with the controller See Tech Note 1 for details NOTE It may also be necessary to use nnconfig exe to assign a specific controller IP address to each remote node rather than to allow nodes to...

Page 9: ...ons of the LEDs Inside the Enterprise Network Controller front cover The front panel of the Enterprise Ultra controller has LEDs connector ports and a lockable hard drive door The table beneath explains the functions of the LEDs HDD TEMP FAN POWER Drive door Lock The front plate of the Enterprise Ultra Network Controller POWER On Green Power is supplied to the unit On Red Redundant power supply fa...

Page 10: ...reen Drive OK Off or On Red Drive failure System Reset This button restarts the Network Controller processes Alarm Reset The Network Controller has an audible alarm which sounds when the power temperature or the fan are in an abnormal state Press this to stop the audible alarm Power Press and hold for 3 to 5 seconds to force a power off NOTE It is not recommended that the unit be powered down in t...

Page 11: ...he Enterprise Ultra to perform this operation The Enterprise Ultra will continue to perform its access control functions throughout this process 6 Open the lockable drive door 7 Slide the drive lock switch to the left See image below 8 Place a finger into the gap to the right of the drive lock switch and pry the drive removal lever out and to the right This will unseat the drive 9 Pull the drive o...

Page 12: ...ngs Network Nodes 2 From the Name drop down select the Node that you will replace 3 Write down the Node name and Unique Identifier for this node You will need to know this later to complete your configuration 4 Select Setup System Maintenance Utilities 5 Click the Shutdown Now button in the System Functions section of this page 6 Please wait for the system countdown to complete and you will hear t...

Page 13: ...6 In the dialog box select from the drop down the newly installed node NOTE If other nodes are powered you may need to know the Unique identifier for this new node to make the correct selection You can use nnconfig exe to get this UID 7 Click Save and confirm the swap in the popup NOTE Since resources inputs outputs readers etc are specific to a node unique identifier the Swap you performed in thi...

Page 14: ...may also be necessary to use nnconfig exe to assign a specific controller IP address to each remote node rather than to allow nodes to Auto Discover the controller 10 Test system access control functions Backup the Enterprise controller 1 Select Administration Utility Backup System 2 Enter a Comment to explain the purpose of this backup 3 Click Full Backup 4 When the backup is complete it is liste...

Page 15: ...amage or to parts which in the judgment of the Company are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if provided at no cost may be discontinued...

Page 16: ...rs Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Reviews: