8. If any nodes are not yet connected to the Enterprise controller, return to step 1 in this
procedure and ensure that all nodes are enabled.
9. If some nodes still will not connect it may be necessary to adjust port forwarding on routers
and gateways to allow the nodes on different subnets to communicate with the controller. See
Tech Note 1
for details.
NOTE
: It may also be necessary to use nnconfig.exe to assign a specific controller IP
address to each remote node, rather than to allow nodes to Auto Discover the controller.
10. Test system access control functions.
Backup the Enterprise controller
1. Select
Administration : Utility : Backup System
.
2. Enter
a
Comment
to explain the purpose of this backup.
3. Click
Full Backup
.
4. When the backup is complete it is listed in the
Existing Backups
section.