![Vicon Roughneck V920D Series Instruction Manual Download Page 11](http://html1.mh-extra.com/html/vicon/roughneck-v920d-series/roughneck-v920d-series_instruction-manual_1012687011.webp)
2. Using the drilling guide as a template, mark the location of the four mounting holes [0.203 in. (5.2 mm)
diameter]. See Figure that follows.
Mounting Hole Pattern
3. There are two (2) cable access holes provided. Drill a hole in the wall or ceiling and route video and
power cables to the selected location and through one of the cable access holes. A 1/2-inch connection
(customer-supplied connector) is provided on the side of the base. A conduit or electrical connector
(screw-type) can be used in this threaded hole. The rear port is sized to accept a 1/2-in. (customer-
provided) connector. If it is desirable to use the rear cable access hole, route the conduit through the
hole; the supplied grommet can be used instead of the conduit. Apply the provided sealant tape around
the threads of the conduit pipe. See Figure above for hole locations.
4. The unit is delivered with all wires inside the housing. The required connections can be made inside the housing
or the cables can be routed outside the housing using either the rear or side access hole. A boot is provided on
the BNC connector to prevent shorting and should NOT be removed. Tie wraps are provided to secure
cables/boot after the connection is made.
5. If using the rear cable access hole, insert the vent plug provided in the side cable access hole. If the side
cable access hole is used, insert a Street Tee (customer provided) into the cable access hole. Route the
conduit through the top hole and insert the vent plug provided into the bottom hole. Refer to Figure that
follows for installation options. Sealant tape is provided for the plug and Street Tee. Insert the black plug
provided into the rear cable access hole if the side access hole is being used; if the rear cable access
hole is being used, insert the provided plug into the side cable access hole and tighten with tool provided.
Installation Options
Installation 11
Note:
For
outdoor installations,
Vicon recommends that the vent plug should only be used if fogging conditions
exist. Additionally, if the side cable access hole is used, the base must be mounted so the hole is
pointed directly downward.
Note:
Failure to thoroughly coat threads will result in moisture entering the housing and eventual failure of the
unit.