background image

3.  There are two (2) cable access holes provided. Drill a hole in the wall or ceiling and route video and 

power cables to the selected location and through one of the cable access holes. A 1/2-inch connection 
(customer-supplied connector) is provided on the side of the base; the rear port is sized to accept a 1/2-
in. (customer-provided) connector. A conduit or electrical connector (screw-type) can be used in this 
threaded hole. See Figures 1 and 2 for hole locations. 

4. 

If it is desirable to use the rear cable access hole, remove the black hole plug it is shipped with and route 
the conduit through the hole. Remove the plug from the side cable access hole and insert the vent plug 
provided. If the side cable access hole is used, remove the plug it is shipped with and insert a Street Tee 
(customer provided) into the cable access hole. Route the conduit through the top hole and insert the 
vent plug provided into the bottom hole. Refer to Figure 3 for installation options.

 

 

Note: 

For 

outdoor installations, 

Vicon recommends that the vent plug should only be used if fogging 

conditions exist. Additionally, if the side cable access hole is used, the base must be mounted so the 
hole is pointed directly downward.  

 
 

 

 

Figure 3 

Installation Options 

5.  Fasten the base to the wall or ceiling with the appropriate hardware for the mounting surface, lag bolts 

and sleeve for cement surfaces or machine screws for other surfaces. A nylon washer is provided at each 
mounting hole for environmental sealing. If the rear cable access is used, be sure that holes are aligned 
correctly so the cable is routed to allow a flush installation of the base. As a mounting alternative, align 
the mounting holes with a 4 x 4 electrical box and fasten the base to the box with machine screws. 

6.  Rotate camera/lens assembly to the desired position. Make sure that the camera/lens assembly is 

oriented correctly, so that the markings on the camera/lens assembly are at the top. Make sure that the 
pan bracket is on the left side of the camera when looking into the lens. 

Do not move the camera/lens 

assembly by holding onto the lens.

 For roll adjustment: simply rotate unit to desired position. If a unit 

with a varifocal lens is being installed, the lens can be manually adjusted for iris, focus and angle of view 
(telephoto/wide). On autoiris models, there is a potentiometer for adjustment. When making adjustments, 
be sure that the lens does not hit the dome. 

 

Note:

 To assure a watertight seal, apply silicone sealant around the area where the base meets the wall or 

ceiling. 

XX137-00-03 Rev 504 Roughneck V910 Dome Cameras 

Installation  

  5 

Summary of Contents for ROUGHNECK V910

Page 1: ...e critical situations and must not be used for this purpose Copyright 2004 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are regis...

Page 2: ......

Page 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Page 4: ...asive or aerosol cleaners d The product does not operate per the operating instructions Perform Vicon recommended adjustments modifications and troubleshooting only to avoid unit damage and personal i...

Page 5: ...6 Video Cable 6 Coaxial 6 Twisted Pair 6 Camera Power Connections 7 Power Supplies 7 Heater Connections 7 Camera Synchronization 8 Camera Lens Adjustments 8 Switch Settings 8 Lens Autoiris Adjustment...

Page 6: ...ed installers use the installation diagram below For complete detailed instructions on how to install the V910 read the Installation section Installation Diagram ii Quick Installation XX137 00 03 Rev...

Page 7: ...available that offers twisted pair video connection A UTP receiver is required for twisted pair configurations Refer to Table 1 for a complete listing of models The Roughneck V910 Dome Camera series m...

Page 8: ...e Components The Roughneck V910 units consist of a base which includes the camera mounting bracket with the camera lens assembly and a cover with a smoked dome Refer to Figure 1 Base Camera Mounting B...

Page 9: ...Figure 1 Exploded View Heater on Outdoor Models only XX137 00 03 Rev 504 Roughneck V910 Dome Cameras Installation 3...

Page 10: ...he V910 unit weighs 4 lb 1 8 kg Video and power cables must be routed to the installation location The V910 mounts directly to a ceiling or wall The base has four mounting holes and two cable access h...

Page 11: ...nward Figure 3 Installation Options 5 Fasten the base to the wall or ceiling with the appropriate hardware for the mounting surface lag bolts and sleeve for cement surfaces or machine screws for other...

Page 12: ...connectors it is recommended that these connections be wrapped with electrical tape to prevent shorts Twisted Pair For the model using the twisted pair video connection use the twisted pair video plug...

Page 13: ...own and insert the wire into the connector body Repeat for each connection Refer to Table 2 Press the cable connector onto the board screw terminal T ower Con umber Function 1 24 VAC 2 24 VAC Return N...

Page 14: ...te the camera and lens can be adjusted Switch Settings lection of Switch 1 ALC OFF or ELC N Switch 2 Internal Crystal Synchronization ON or Line Lock OFF Switch 3 AGC ON or OFF Switch 4 BLC ON or OFF...

Page 15: ...Figure 6 Location of Autoiris Potentiometer Figure 7 Switch Settings XX137 00 03 Rev 504 Roughneck V910 Dome Cameras Installation 9...

Page 16: ...the camera mounting bracket This keeps the mask in place and allows it to rotate with the camera lens assembly Reattach the cover to the base by aligning the four captive screws with the holes in the...

Page 17: ...essed air cans 3 If spots streaks or stains appear on the interior or exterior they can be removed with a solution of isopropyl alcohol and water using a microwave safe aluminum free paper towel Dry w...

Page 18: ...United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon...

Page 19: ...uality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a guide in choosing the best cable type For cables other than the approved Vic...

Page 20: ...e video signal is sent as a twisted pair the blue white white blue wires twisted together as a pair not a split pair blue white conductor part of one pair orange white conductor part of another pair C...

Page 21: ...414 134 700 213 1120 341 1750 533 Heat Equivalent Indoor 0 27 btu min 0 07 kg cal min without heater Outdoor Color 1 16 btu min 0 29 kg cal min with heater Outdoor Day Night 1 23 btu min 0 31 kg cal...

Page 22: ...ds up to 80 mph OPERATIONAL Tilt and Horizont A MECHANICAL Application Mounting Ceiling or wall Dimensions Height 5 1 in 1 Dome Diameter 4 7 in 1 Approximately 4 lb 1 8 kg Construction Base Cover die...

Page 23: ...ne lock DIP switch selectable NTSC 1 60 1 100 000 PAL 1 60 1 100 000 48 dB AGC off V910VF DN V910VF DN C 1 4 CCD 2 1 interlace NTSC PAL Color Color 480 Mono 580 Day 0 07 0 8 Night 0 009 0 01 at 40 IRE...

Page 24: ...be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been tampered with altered misus...

Page 25: ...ters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far...

Reviews: