background image

8  

••

  Shipping Instructions 

X683 Rev 100 V6-60HS-1 Zoom Lenses 

Shipping Instructions 

Use the following procedure when returning a unit to the factory: 
 

1.  Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of 

the Vicon employee who issued the R.A. 

 

Vicon Industries Inc. 
89 Arkay Drive 
Hauppauge, NY  11788 
Phone: 631-952-CCTV (2288); Toll-Free: 1-800-645-9116; Fax: 631-951-CCTV (2288) 

 

For service or returns from countries in Europe, contact: 

 

Vicon Industries (U.K.) Ltd 
Brunel Way 
Fareham, PO15 5TX 
United Kingdom 
Phone: 44/(0)1489/566300; Fax: 44/(0)1489/566322 

 

2. 

Attach a sheet of paper to the unit with the following information: 

 

a. 

Name and address of the company returning the unit 

b. 

Name of the Vicon employee who issued the R.A. 

c. 

R. A. number 

d. 

Brief description of the installation 

e. 

Complete description of the problem and circumstances under which it occurs 

f. 

Unit’s original date of purchase, if still under warranty 

 

3.  Pack the unit carefully. Use the original shipping carton or its equivalent for maximum protection. 

4.  Mark the R.A. number on the outside of the carton on the shipping label. 
 

Summary of Contents for 5860

Page 1: ...Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 INFOFAX 800 287 1207 WEB www vicon cctv com ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...us video drive autoiris operation This additional feature provides optimum viewing contrast regardless of light conditions or brightness variations within the scene In the AC lens the iris is controlled by a stepping motor which is virtually unaffected by vibration or operating position The microcomputer iris control provides precise responsive iris operation The V6 60AC HS P 1 has the same featur...

Page 6: ...2 Introduction X683 Rev 100 V6 60HS 1 Zoom Lenses Notes ...

Page 7: ...6 mm of clear space between the extended lens and the window Caution Control units having the three position distance switch MUST NOT be set for longer than recommended distances or the lens may be seriously damaged Caution Do not mount an autoiris lens on a camera that is installed on an autopanning unit Such use causes excessive wear as the iris mechanism constantly compensates for different lig...

Page 8: ...ire Color Function 1 White Iris drive 1 White Iris drive 2 Red Zoom drive 2 Red Zoom drive 3 Green Focus drive 3 Green Focus drive 4 Black Common 4 Black Lens common 5 Not used 5 Gray Potentiometer return 6 White Black Ground or shield 6 Brown Potentiometer supply 7 Blue Zoom wiper 8 Yellow Focus wiper 9 White Black Ground or shield Figure 1 Connector Diagrams M and MS Lenses ...

Page 9: ...le it is supplied with the camera and should be wired according to the instructions provided with the camera The cable controlling the autoiris drive in an AC lens may consist of three or four conductors and a shield For proper operation the shield of the cable MUST be grounded to the same pin as the black common conductor If the autoiris cable has four conductors the green conductor is not used a...

Page 10: ... setting to infinity is adjustable from 2 to 8 seconds To make the adjustment remove the cap over the potentiometer and turn it to adjust the speed Turn the potentiometer clockwise to increase speed Refer to Figure 3 Iris Speed Adjustment Iris speed is adjustable on the MS lens which provides remote manual iris control The AC lens which features autoiris operation does not have an iris speed adjus...

Page 11: ... to produce a satisfactory picture adjust the LEVEL potentiometer The adjustment limits are low L and high H Note When making an adjustment turn the potentiometer a little at a time 1 Set the camera AGC to OFF 2 Remove the rubber cap from the potentiometer and adjust it If the contrast is too strong turn the potentiometer counterclockwise toward L if the contrast is too weak turn the potentiometer...

Page 12: ... Europe contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circums...

Page 13: ...nectors Standard lens Vicon part number 8000 9800 00 on pendant cable Mating connector 8000 9736 00 supplied Preset lens Vicon part number 8000 9801 00 on pendant cable Mating connector 8000 9645 00 supplied Cable Requirements Without presets 4 conductor shielded With presets 8 conductor shielded AC Lenses Input Voltage Iris 8 16 VDC Zoom and focus 6 12 VDC Operating Current Iris 40 mA max Zoom an...

Page 14: ...ange 2 8 sec adjustable Zoom Speed Range 2 7 sec adjustable MECHANICAL Dimensions Height 2 6 in 66 mm Width 3 0 in 76 mm Length 4 7 in 119 mm Optical center to bottom 1 3 in 34 mm Distance from bottom mounting hole to mounting flange 1 2 in 31 mm Weight 1 4 lb 0 6 kg Mount Type CS mount Filter Threads Diameter 58 mm Pitch 0 75 mm Maximum Lens Penetration into Camera 0 28 in 7 1 mm Mounting Hole 20...

Reviews: