EXHIBIT
Exhibit
Troubleshooting
Error Description
Cause
camera station gives no video
signal
♦
check the power supply connection (230
V AC or 12 V DC) to the connection cir-
cuit board
♦
check the connection of the video cable
to the connection circuit board
♦
check the function of your power supply
(12 V DC)
♦
check the connections to the camera
(video / power)
housing not water-tight, intrusion
of water
♦
check the mounting of the housing
♦
check all seals for correct mounting and /
or defects
front pane shows condensation
♦
check the function of the heater
Maintenance and Care
Disconnect the housing from power supply before starting to clean it. For reasons of
electrical safety never clean the camera with water or other liquid matters and never put
the device under water. Only use a soft dry cloth for cleaning the housing. A cleaning of
the housing’s interior may only be carried out by authorised personnel.
Make sure to include these instructions when handing the device over to third parties.
In order to maintain the IP 67 rating, check the housing seals whenever the housing is
opened for maintenance and replace them if necessary.
Technical Support
Should you have any problems during installation you can reach our Technical Hotline
under the following telephone number: +49 (0) 4321 879 400.