background image

 

 

 

 

VIAVI Solutions

 

Quick Card 

 

T-BERD

®

/MTS-2000 Modular Test Set

  

FTTA OTDR, Cell Tower Maintenance 

 
This quick card explains how to connect to a fiber under test, configure Fiber to the Antenna (FTTA) 
OTDR test setups, run tests, and analyze results with a VIAVI T-BERD/MTS-2000 equipped with a 4100-
series OTDR module to troubleshoot cabling component problems such as fiber breaks or high loss and 
reflective defects (dirty connectors, fiber mismatches, misalignment, macro-bends/kinks, etc.) 

Equipment Requirements: 

 

T-BERD/MTS-2000 equipped with the following: 

o

 

Fiber Optics Software Release V16.22 or greater 

o

 

E4100 Series OTDR Module 

o

 

Software options for FTTA OTDR and SmartLink  
Mapper (SLM) icon-based OTDR results 

 

Fiber optic cleaning and inspection tools 

 

20-meter fiber optic patch cord (Launch Cable) with  
connectors that match the OTDR Port and Fiber 
Under Test (SC UPC, SC APC, LC UPC, etc.) 

 

Optical Coupler to connect Launch Cable to BBU  
Jumper Cable or Trunk Cable 

The following information is required to complete the procedure: 

 

Type of Fiber (Multimode or Single Mode) 

 

Type of Connectors (SC UPC, SC APC, LC UPC, etc.) 

 

Tower architecture: 

o

 

Is there a BBU jumper cable? 

o

 

Is there an RRU jumper cable? 

 

RRU and BBU/Base Station IDs 

 

Fiber Code (1-Rx, 1-

Tx, …, 

24-Tx) 

 

Distance unit (feet or meters) 

Fiber Inspection Guidelines: 

Inspect and clean (if necessary) both sides of every connection being 
used (bulkhead connectors, patch cords, and OTDR port) prior to 
reconnection for each test.  Using the P5000i or FiberChek Probe: 

 

Focus fiber on the screen.  If dirty, clean

 

the connector 

 

If it appears clean, run inspection test. 

 

If it fails, clean fiber and re-run inspection test.  Repeat until it 
passes. 
 

 

Figure 1: FiberChek Probe 

 

Figure 2: Image of Clean Fiber

Summary of Contents for T-BERD/MTS-2000

Page 1: ... fiber optic patch cord Launch Cable with connectors that match the OTDR Port and Fiber Under Test SC UPC SC APC LC UPC etc Optical Coupler to connect Launch Cable to BBU Jumper Cable or Trunk Cable The following information is required to complete the procedure Type of Fiber Multimode or Single Mode Type of Connectors SC UPC SC APC LC UPC etc Tower architecture o Is there a BBU jumper cable o Is ...

Page 2: ...er 1 Inspect and clean the OTDR port on top of the test set 2 If the interface to the FUT is the BBU Jumper or Trunk Cable connect the cable to an optical coupler with the same connector type 3 Inspect and clean the FUT connected to the coupler or OPP 4 Inspect and clean fiber end face of the Launch Cable 5 Connect the Launch Cable to the OTDR port 6 Inspect and clean the other fiber end face of t...

Page 3: ...nance SM OTDR for single mode fiber or FTTA_RRU_Maintenance MM OTDR for multimode fiber 8 Tap the Load as FTTA Config soft key 9 Tap the Analysis soft key Set BBU Jumper to Yes if there is a BBU Jumper Cable between the Launch Cable and OPP Set BBU Jumper to No if the Launch Cable is directly connected to the OPP Set RRU Jumper to Yes if there is a Junction Box OPP at the top of the tower between ...

Page 4: ...loss or reflectance are shown in RED Use the right and left arrow button to Toggle between results for each wavelength Tap the Zoom soft key to enable zoom controls with the following buttons Toggle between automatic zoom and full trace view Expand and contract trace b SmartLink Summary view The FUT is displayed as a series of icons representing events connectors splices bends etc The center of th...

Reviews: