Viavi T-BERD/MTS-2000 Quick Card Download Page 4

 

 

 

 

 

 

 

 

VIAVI Solutions

 

Contact Us      +1 844 GO VIAVI 

     (+1 844 468 4284)

 

To reach the VIAVI office nearest you, 
visit viavisolutions.com/contacts. 

© 2018 VIAVI Solutions Inc.   
Product specifications and descriptions in this 
document are subject to change without notice.

 

 

Run Test: 

1.

 

 

Press the 

RESULTS

 button.

 

2.

 

 

Press the 

START/STOP

 button to start the test.  After auto-configuration, the OTDR will perform 

a connection check to ensure that the connection is 

Good

. If the Connection is 

Bad

, repeat steps 1 through 7 

on page 2.   

 

3.

 

The OTDR will perform acquisitions at two wavelengths and the trace file will be saved to disk.  Results may 
be displayed in 3 different formats: Trace view, SmartLink Summary View, or SmartLink Event View.   

Tap the 

Trace/SmartLink

 soft key 

, to toggle between 

Trace view

 and 

SmartLink views

.   

Tap the 

 soft key to toggle between the 

SmartLink Summary

 view and 

SmartLink Event View

:

 

a.

 

Trace view

:  Results for each wavelength are shown in different 

colors in the top section of the display.  Each event is listed in 
the lower section of the display. Any events that violate 
pass/fail thresholds for loss or reflectance are shown in 

RED

Use the right and left arrow button to Toggle between results 

for each wavelength.  Tap the 

Zoom

 soft key 

, to enable 

zoom controls with the following buttons: 

 

 

Toggle between automatic zoom and full trace view 

 

    Expand and contract trace. 

b.

 

SmartLink Summary view:

  The FUT is displayed as a series of 

icons representing events (connectors, splices, bends, etc.).  The 
center of the display shows summary results per wavelength for 
the entire span.  Acquisitions for which all events are acceptable 
are marked with a green check 

.  Acquisitions with events 

that exceed pass/fail thresholds for loss or reflectance are 
marked with a red 

.  The lower display shows each event that 

exceeds thresholds. 

c.

 

SmartLink Event view:

  The FUT is displayed as a series of labels 

icons representing each event in the trace: 

 

BBU:  

Connection (coupler) between launch cable and BBU 

Jumper Cable  

 

BOT TWR

:  Optical Patch Panel at bottom of tower 

 

TOP TWR

:  Junction Box/Patch Panel at Top of tower 

 

RRU

:  End of RRU Jumper Cable 

Any events that violate pass/fail thresholds for loss or 
reflectance are shown in 

RED

.  Tap on any event to display 

details in the lower display.   

 

 

Figure 3: Trace view 

 
 

 

Figure 4: SmartLink Summary View 

 
 

 

Figure 5: SmartLink Event View

4.

 

Repeat steps 2 and 3 for all Fibers under test. 

Summary of Contents for T-BERD/MTS-2000

Page 1: ... fiber optic patch cord Launch Cable with connectors that match the OTDR Port and Fiber Under Test SC UPC SC APC LC UPC etc Optical Coupler to connect Launch Cable to BBU Jumper Cable or Trunk Cable The following information is required to complete the procedure Type of Fiber Multimode or Single Mode Type of Connectors SC UPC SC APC LC UPC etc Tower architecture o Is there a BBU jumper cable o Is ...

Page 2: ...er 1 Inspect and clean the OTDR port on top of the test set 2 If the interface to the FUT is the BBU Jumper or Trunk Cable connect the cable to an optical coupler with the same connector type 3 Inspect and clean the FUT connected to the coupler or OPP 4 Inspect and clean fiber end face of the Launch Cable 5 Connect the Launch Cable to the OTDR port 6 Inspect and clean the other fiber end face of t...

Page 3: ...nance SM OTDR for single mode fiber or FTTA_RRU_Maintenance MM OTDR for multimode fiber 8 Tap the Load as FTTA Config soft key 9 Tap the Analysis soft key Set BBU Jumper to Yes if there is a BBU Jumper Cable between the Launch Cable and OPP Set BBU Jumper to No if the Launch Cable is directly connected to the OPP Set RRU Jumper to Yes if there is a Junction Box OPP at the top of the tower between ...

Page 4: ...loss or reflectance are shown in RED Use the right and left arrow button to Toggle between results for each wavelength Tap the Zoom soft key to enable zoom controls with the following buttons Toggle between automatic zoom and full trace view Expand and contract trace b SmartLink Summary view The FUT is displayed as a series of icons representing events connectors splices bends etc The center of th...