DOCSIS 3.1 Signal Testing and Troubleshooting
Level variation
within
the OFDM channel band
provides insight into
frequency-response
related issues.
Spectrum
and
noise
identify portions of
a carrier where degradation may occur
and require possible profile adjustment.
Unstable MER with drops below
30dB
means only profiles running
256 QAM or lower will work.
Stable
MER better than 40 dB
means
QAM 2048 and 4096 will work.
In-Channel
Response
identifies
roll-off and excessive
ripple
Measuring MER across entire subcarrier list enables identifying
potential impairments with impact on higher level profiles