background image

MANUAL  VIAVAC-CB4 / 4.1   ( Operator section )                                                       Art. nr. 50504 EN (01-07-2017) 
__________________________________________________________________________________________ 

6

 

___________________________________________________________________________________ 

VIAVAC vacuum lifting BV               T. + 31 348 449 660                 E. [email protected]         I. www.viavac.com

 

 

 

 
Before any lift, the user must check the following: 

 
I.  

Check the rubber sealing profile of the suction pad for damage and cracks, replace if necessary. 

II  

Check rubber back plate of the suction pad to verify whether it is clean and free from grease, oil or 

    

water drops and, if necessary, to  clean it up. 

III  

Whether the battery is sufficiently charged; The volt meter (8) must indicate between 11 and 13 Volt. 

IV  

Functioning of the acoustic alarm (11) at a vacuum level below -0.60m bar. 

   

This can be checked by briefly putting the control lever (8

) in the position “

suction

” (green area) 

 

  

before the suction pad is placed on the load. 

 
  

Remove excessive water, snow and ice at the area where suction pads are placed on load. 

  

This is essential to have suffucient friction needed for lifting in vertical or inclined position. 

  

 

 

  

If the load has a protective film, it must first be removed before the  suction pad is placed on the 

  

load. 

 
 

During every lift the operator must constantly monitor the following: 

 
a.  

Vacuum meter, during lifting the pointer must constantly remain in the green area. 

b.  

Acoustic alarm signal; during the lift it may not be audible. 

 
 

If the vacuum meter is in the red area and/or the acoustic alarm signal sounds, do not lift! 

  

If the vacuum meter is in the read area and/or the acoustic alarm signal sounds, a lifted load must be 

  

put down as quickly as possible. 

 
  

If the vacuum pump for some reason fails, from the moment the vacuum level 

     

decreases below the required level of> -0.60,  the load will be held for a minimum of 5 minutes. 

 

To work safely with the device, it is therefore necessary that:

 

-    The operator must have good hearing and is not using hearing protection. 
-    During the lifting the operator must be within hearing and visibility distance of the device. 

The ambient sound does not amount to more than 70db. 

The operator of the device is constantly in contact with the operator of the lifting machine and 

   

agreements have been made about a clear communication. 

 

Protective precautions at operation temperatures between the -10

o

C and 0

o

C.

 

-    To prevent clogging of the filters, it has to be ensured that all the humidity has been removed from the 

device. This is achieved by letting the vacuum pump run approx. 15 minutes with the control level (9) in 

the position “suction” in a dry and heated compartment.

 

-  

To be assured of sufficient battery capacity, store the device at a temperature of 15

o

C or higher at night. 

 -   For sufficient friction between suction pad and the load, it must be ensured for every lift that both the 

suction pad and the suction surface of the load, all water, snow and ice is  removed.  
 

 

 

Summary of Contents for 50504

Page 1: ...NSTRUCTION MANUAL Battery powered below the hook vacuum lifting device for sandwich roof and wall panels __________________________________________________________________________________________ __________________________________________________________________________________________ Read this manual carefully before operating this lifter ...

Page 2: ...laration of conformity 5 A 3 Definitions 6 B 1 Operators declaration 1 B 2 Operating limits 2 B 3 Operation 3 B 4 Storage 7 B 5 Battery 8 B 6 Transport and manipulation possibilities 9 B 7 Options 21 B 8 Safety precautions 27 C 1 Expert declaration 1 C 2 Technical data 2 C 3 Checking and maintenance 3 C 4 Inspection maintenance report 6 C 5 Fitting sealing profile in suction pad 8 C 6 Mal function...

Page 3: ...this manual B Operators section This section is intended for anyone who utilizes and operates this device C Technical section This section is intended for the specialist staff who take care for maintenance and repair of this device Depending your function you need to read carefully the belonging section To operate this device safely it is important that you strictly follow the instructions If you ...

Page 4: ...ated Suction and release by ball valve on the main unit CB 4 1 Remote control operation Suction and release is possible because of electric valve on the main unit Optional there are 2 type of remote control can be installed 1 Remote control box connected with electric cable to the main unit 2 Radio Remote control by transmitter and a built in receiver in the main unit These versions differ only co...

Page 5: ... Machine nr Complies with the following standards and directives Machine directive 2006 42 EG with alterations Low voltage directive 2014 35 EU EMC directive 2014 30 EU American standard ASME B30 20 2010 American standard ASME BTH1 2011 design category A Service Class 0 Australian Standard AS 4991 2004 The following European standards have been applied Safety of machinery Basic concepts EN ISO 121...

Page 6: ...ting a valve sucking the load fixed to the suction pad Aerating By actuating a valve releasing the load by enabling air flowing to the suction pad Maintenance expert Expert who is responsible for inspection maintenance and repair of the vacuum lifting device Load ratio Ratio between the maximum calculated load which can be lifted with the device and the safe working load which is indicated on the ...

Page 7: ...____________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com B 1 Operators declaration The undersigned hereby declares that before operating this vacuum lifter he has read and understood the operators section of this instruction manual and will follow the instructions and guidelines Control of the management on compliance is required DATE NAME S...

Page 8: ... settings vacuum switch needs to be adapted Operating Temperatures 0o C to 40o C 10o C to 0o C with special precautions Service life At least 20 000 cycles 10 years when properly maintained and used as intended Outside use This lifter can also be used outside however not in area with explosive danger Rain and snow This lifter may also be used in rain and snow conditions however there should be tak...

Page 9: ...____________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com B 3 Operation CB 4 Vacuum unit with handle suction release Lifting lug 1 Vacuum indicator 2 Main switch 3 Storage box 4 Cable battery charger Button 5 Open close Filter water seperator 6 7 Volt indicator 8 Handle suction release 9 Acoustic warner 10 Vacuum connections 11 Tiltable main traverse 12 Securing han...

Page 10: ...lectro magnetic 3 2 valves 3 buttons on the front door for suction 1 green and release 2 red buttons Connector to fit additional remote control on cable Buttons for control Connector for additional suction release remote control box on cable __________________________________________________________________________________ Cable remote control This can easily be installed by simply connecting the ...

Page 11: ...8 at suction green area 10 Check on the vacuum meter 2 whether the required vacuum level of 0 60 bar has been built up pointer in the green area 11 If used on the building site in the EU lift the load a little and attach the fall safety straps as indicated 12 The load can now be lifted further and just before the load is set on its place the falling safety strap should be removed if applicable 13 ...

Page 12: ...antly remain in the green area b Acoustic alarm signal during the lift it may not be audible If the vacuum meter is in the red area and or the acoustic alarm signal sounds do not lift If the vacuum meter is in the read area and or the acoustic alarm signal sounds a lifted load must be put down as quickly as possible If the vacuum pump for some reason fails from the moment the vacuum level decrease...

Page 13: ...d Then it must take at least 30 seconds before it starts pumping again If the pump starts up more frequently this indicates a leak and this causes the battery to discharge faster than expected and one cannot operate for a whole day Therefore it is advisable to first rectify this before the work is continued Reduced lifting capacity at higher altitudes Lifting capacity of the suction pads are set a...

Page 14: ...h to maintenance loading The connector can therefore remain in the electric socket without any danger of overloading the battery In case of a charged battery the volt meter on the cabinet indicates between 12 14 Volt when the vacuum pump runs it will fall back with approx 1V If the meter falls back significantly to back with 2 or more Volt during additional pumping this means that the battery is d...

Page 15: ...________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com B 6 Transport and manipulation possibilities TYPE SANDWICH ROOF PANELS type RA 1 0 5 0 7mm Steel aluminium PUR EPS 0 4 0 7mm Staal aluminium type RB 2 0 5 0 7mm Steel aluminium PUR EPS Foil type RB 3 0 5 0 7mm Steel aluminium Mineral wool 0 4 0 7mm Steel aluminium type RB 4 0 5 0 7mm Steel aluminium PUR E...

Page 16: ...panels with min 0 5mm steel skin EPS PUR PIR core Type RB roof panels with min 0 5mm steel skin mineral wool core Max wind speeds L up to 12 meter 11m s 12 up to 16 meter 9m s REMARKS Panels with a length up to 20 meter are possible with configuration type RC 8000 9800 Panels with a roof pitch 250 up to 450 are possible with configuration RT 2600 4400 6200 ITEM QUAN DESCRIPTION ART NR 1 1 Vacuum m...

Page 17: ...anels with min 0 5mm steel skin EPS PUR PIR core Type RB roof panels with min 0 5mm steel skin mineral wool core Max wind speeds L up to 12 meter 11m s 12 up to 16 meter 9m s REMARKS Panels with a length up to 20 meter are possible with configuration type RC 8000 9800 Panels with a roof pitch 250 up to 450 are possible with configuration RT 2600 4400 6200 ITEM QUAN DESCRIPTION ART NR 1 1 Vacuum mo...

Page 18: ...n 0 5mm steel skin PUR PIR core Type RB roof panels with min 0 5mm steel skin mineral wool core Max wind speeds L 16 up to 20 meter 8m s REMARKS Panels with shorter lengths are possible with configuration type R 2600 4400 6200 Panels with a roof pitch 250 up to 450 are possible with configuration RT 2600 4400 6200 ITEM QUAN DESCRIPTION ART NR 1 1 Vacuum module CB4 408500 2 6 8 Extension beam 40800...

Page 19: ...kin PUR PIR core Type RB roof panels with min 0 5mm steel skin mineral wool core Max wind speeds L 16 up to 20 meter 8m s REMARKS Panels with shorter lengths are possible with configuration type R 2600 4400 6200 RC 8000 9800 Panels with a roof pitch 250 up to 450 are possible with configuration RT 2600 4400 6200 ITEM QUAN DESCRIPTION ART NR 1 1 Vacuum module CB4 408500 2 8 10 Extension beam 408003...

Page 20: ... PIR core Type RB roof panels with min 0 5mm steel skin mineral wool co Max wind speeds L up to 20 meter 8m s 20 up to 26 meter 6m s REMARKS Panels with shorter lengths are possible with configuration type R 2600 4400 6200 RC 8000 9800 Panels with a roof pitch 250 up to 450 are possible with configuration RT 2600 4400 6200 ITEM QUAN DESCRIPTION ART NR 1 1 Vacuum module CB4 408500 2 16 18 Extension...

Page 21: ... with min 0 5mm steel skin PUR PIR core Type RB roof panels with min 0 5mm steel skin mineral wool core Max wind speeds L up to 12 meter 8m s 12 up to 16 meter 6m s REMARKS Panels with a roof pitch 00 up to 250 are possible with configuration R 2600 4400 6200 Panels with a length up to 20 meter are possible with configuration type RC 8000 9800 ITEM QUAN DESCRIPTION ART NR 1 1 Vacuum module CB4 408...

Page 22: ...___________ 16 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com TYPE SANDWICH WALL PANELS type WA 1 0 5 0 7mm Steel aluminium PUR EPS 0 5 0 7mm Steel aluminium type WB 2 0 5 0 7mm Steel aluminium Mineral wool 0 5 0 7mm Steel aluminium ...

Page 23: ... length Other type of suction pads on request load with 4x100kg pads max possible load on traverse Type WA wall panels with min 0 5mm skin PUR PIR core Type WB wall panels with min 0 5mm steel skin mineral wool core REMARKS Panels with a length up to 17 meter are possible with CB configuration type WVK 2900 4700 ITEM QUAN DESCRIPTION ART NR 1 1 Vacuum unit CB4 408500 2 2 4 Suction pad with suspens...

Page 24: ... on request load with 4x100kg pads max possible load on traverse Type WA wall panels with min 0 5mm skin PUR PIR core Type WB wall panels with min 0 5mm steel skin mineral wool core REMARKS Panels with a length up to 12 meter are possible with CB configuration type WV ITEM AANTAL DESCRIPTION ART NR 1 1 Vacuum unit CB4 408500 2 1 Tilting beam 408006 3 2 4 Extension beam 408003 4 1 set Traverse cros...

Page 25: ... length Other type of suction pads on request load with 4x100kg pads max possible load on traverse Type WA wall panels with min 0 5mm skin PUR PIR core Type WB wall panels with min 0 5mm steel skin mineral wool core REMARKS Panels with a length up to 15 meter are possible with configuration type WH 1100 2900 ITEM QUAN DESCRIPTION ART NR 1 1 Vacuum unit CB4 408500 2 1 2 sets Suction pad with suspen...

Page 26: ...uction pads on request load with 4x100kg pads max possible load on traverse Type WA wall panels with min 0 5mm steel skin PUR PIR core Type WB wall panels with min 0 5mm steel skin mineral wool core REMARKS Panels with a length up to 12 meter are possible with configuration type WH ITEM QUAN DESCRIPTION ART NR 1 1 Vacuum unit CB4 408500 2 0 2 Traverse extension beam 408003 3 4 Suction pad with sus...

Page 27: ...EM QUAN DESCRIPTION WEIGHT kg ART NR 1 1 Falling safety strap with sling 30 270 100 17003 ITEM QUAN DESCRIPTION WEIGHT kg ART NR 1 1 Falling safety strap with hook 30 270 30 17004 According CE regulation EN 13155 it is in all countries of the European union when a vacuum lifter is used at building site a secondary safety system is obliged This can be realized in the following way s One single vacu...

Page 28: ...safety device is hooked to the therefore intended fixing points on the device 1 2 Lift the element with the vacuum lifter approx 0 5 meter free from the ground 3 Consequently the straps are at both ends put around the element as indicated above 4 Through the clamp buckle 2 the strap is pulled tight around the element no clearance 5 With the lifting device the whole unit is lifted to the designated...

Page 29: ...m we advise to do this with 2 persons __________________________________________________________________________________________ 1 2 3 1 2 3 4 5 5 __________________________________________________________________________________________ 1 To be able to mount the tilting beam the traverse under the device has to be tilted approx 45o Therefore it has to be unlocked by lifting the securing handle 1 ...

Page 30: ..._____________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com B 7 3 Adjustable suspension Improves vertical hanging of thick and heavy horizontal wall panels Must be fitted to the standard lifting eye ITEM QUAN DESCRIPTION WEIGHT kg ART NR 1 1 Adjustable suspension 5 290106 ...

Page 31: ...nsport the device compact together with it s accessories within pallet size 120x100cm __________________________________________________________________________________________ The vacuum unit has to be put with the tilting mechanism in the foundation bin when the device can be attached to the frame by the securing pin 1 1 ___________________________________________________________________________...

Page 32: ...26 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com B 7 5 CB transport wheelset The transport wheels are usefull to transport the unit without the use of a forklift or cran ITEM QUAN DESCRIPTION WEIGHT kg ART NR 1 1 set Transport wheels 12 408011 ...

Page 33: ...fter use 8 5 Always take care that the contact area of the load is clean and dry before placing the suction pad on the surface 8 6 Always position the suction pad correctly on the load 8 7 Always put down the load immediately when the alarm sounds 8 8 Always the operator should be within sight and hearing distance of the lifter and the operator of the lifting machine 8 9 Always there should be an ...

Page 34: ...h this lifter 8 20 Never lift a load which is buckled 8 21 Never lift a load when any vacuum indicator showing an inadequate vacuum 8 22 Never lift a load when the alarm sounds 8 23 Never lift a load higher than necessary 8 24 Never leave suspended loads unattended 8 25 Never lift a load over people 8 26 Never store the lifter standing on the suction pad 8 27 Never lift a load at wind speeds excee...

Page 35: ...________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com C 1 Expert declaration The undersigned hereby declares that before he performs maintenance or repair to this vacuum lifter he has read and understood the operators section of this instruction manual and will follow the instructions DATE NAME SIGNATURE ...

Page 36: ...ructured surface The suction pad seal can compensate when not too rough unevenness s up to 5mm Functions 90o tilting mechanism Lifting capacity max 800kg depending of configuration and the active suction pads at 0 60 bar vacuum level Own weight 100kg Dimensions 905x850x265 Power supply Battery 12V 50Ah Battery charger Primary 110 240V Secondary 12V 4A Vacuum pump 2x Piston pump 12V capacity each 1...

Page 37: ...after pertain to the minimum requirements with regard to maintenance It is advisable to perform these activities more frequently if the circumstances make this necessary such as with increased frequency of use resulting in more wear and tear corrosion and or an increased defect pattern Daily a Check rubber sealing profile 15 for presence of wear and tears and replace if necessary b Check whether r...

Page 38: ...oints or parts which require lubrication The vacuum pump is completely maintenance free and lubrication is not allowed In vertical position of the suction pad the load is held by the friction between the rubber back plate of the suction pad and the load therefore it is essential that this is clean dry and oil free Monthly cleaning of the rubber back plate with natural vinegar ensures that the requ...

Page 39: ...should sound the volume thereof should amount to at least 85db at 1 meter of distance Control of the vacuum pump Hereby the device must be put on a non porous sheet of glass metal or plastic after which suction is applied and waited until the pump stops running By slowly opening the water drain valve 12 the system will be gradually be aerated and the vacuum level will decrease As soon as the vacuu...

Page 40: ...g profiles checked for cracks and wear O O O O Replace the sealing profile O Rubber back plate cleaned and free from grease O O O O Rubber back plate cleaned with natural vinegar O O O Replace the rubber backplate O Filter water separator Remove water and dirt from bowl O O O O Clean filter in bowl O O Water Drain by opening valve when used in rain O O O O Falling safety device for vertical wall p...

Page 41: ...in sucked state max 10 in 60 sec O O O Vacuum indicator Compare level of vacuum indicator with digital vacuum switch 0 03 bar O O O O Battery Capacity test min 85 of 55Ah O O Replace preventative O Charging current of battery charger min 13V O O Level indicator Voltmeter max 1V difference O O Tests O Static load test 2x working load O O Holding time test min 5 minutes O O Stickers Presence of all ...

Page 42: ...____________________________________________________ 8 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com 15 18mm C 5 Fitting sealing profile in suction pad Lip at outside of suction pad 1 2 3 4 ...

Page 43: ...in another way Battery is low Charge battery or replace 3 Sufficient vacuum level Acoustic warning signal sounds Relais K2 is defect Replace relais K2 Vacuum switch is deprogrammed Re programm or replace Leakage of non return valve Clean non return valve or replace Capacity of vacuum pump has decreased Replace vacuum pump or valveplate in de vacuum pump 4 Sufficient vacuum level No acoustic warnin...

Page 44: ...___________________________________________________________________________________ 10 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com C 7 Electric diagram CB4 ...

Page 45: ... 2017 __________________________________________________________________________________________ 11 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com ...

Page 46: ... 2017 __________________________________________________________________________________________ 12 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com ...

Page 47: ... 2017 __________________________________________________________________________________________ 13 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com ...

Page 48: ...17 __________________________________________________________________________________________ 14 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com CB4 1 ...

Page 49: ... 2017 __________________________________________________________________________________________ 15 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com ...

Page 50: ... 2017 __________________________________________________________________________________________ 16 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com ...

Page 51: ... 2017 __________________________________________________________________________________________ 17 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com ...

Page 52: ... 2017 __________________________________________________________________________________________ 18 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com ...

Page 53: ...___ 19 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com C 8 Vacuum diagram CB4 ITEM DESCRIPTION 1 Vacuum pumps 2 Non return valve 3 Vacuum switch 4 Vacuum reserve tank 5 2 way ball valve 6 Vacuum indicator 7 Water drain valve 8 Suction pads ...

Page 54: ...M When the vacuum level sinks below 0 60 bar the acoustic alarm will sound and the red lamp will light up and when the vacuum level increases above 0 60 bar the acoustic alarm stops and the green lamp lights up VACUUM PUMP When the vacuum level sinks below 0 65 bar the vacuum pump starts running and will switch off after 10 seconds Mode Display Up LED out 2 Down LED out 1 The settings of the digit...

Page 55: ...ion Type Art no A 1 A 1 Battery 12V 50AH 33027 1 B 1 Battery charger 12V 4A 33017 1 C 1 LED fixture 22mm red 9054 1 D 1 LED fixture 22mm green 9055 1 E 1 LED lamp red 12V 9058 1 F 2 LED lamp green 12V 9057 1 G 2 LED adaptor 9056 2 A 2 Vacuum pump 12V 1 5m3 23002 2 B 1 Vacuum gauge set Ø63mm 1 4 276502 2 C 1 Volt indicator Ø53mm 12V 31010 2 D 1 Acoustic alarm Ø32mm 5 16VDC 96dB 162105 2 E 1 PICO va...

Page 56: ...nded spare part X Recommended spare part VIAVAC CB4 1 vacuum unit prepared for remote control Art no 257212 A B C D E F G 1 Pict Quan Description Type Art no A 1 A 1 Electro magnetic 3 2 valve 12VDC 177605 1 B 1 Connector female 155201 1 C 1 D 1 E 1 F 1 G Adjustable suspension Art no 290106 A B C D E F G 1 Pict Quan Description Type Art no A 1 A 1 Suspension lock CB 290105 X 1 B 1 Suspension frame...

Page 57: ...part X Recommended spare part CABLE REMOTE CONTROL Art no 278201 A B C D E F G 1 Pict Quan Description Type Art no A 1 A 1 Connector male 155101 1 B 1 Connector switch NC ZC2 BE102 9070 X 1 C 1 Connector switch NO ZB2 BE101 9069 X 1 D 1 Rubber covered magnet 19mm 227102 1 E 1 Green button XAC A413 9068 X 1 F 1 Red button Male 9067 X 1 G RADIO REMOTE CONTROL Art no 278206 A B C D E F G 1 Pict Quan ...

Page 58: ... C D E F G 1 Pict Quan Description Type Art no A 1 A 1 Sping cotter pin 3mm double 1007 1 B 1 Securing pin with suspension Ø16x120 Lc 400 408015 1 C 2 2 ear hose clamp Rnd 17 20mm 12004 X 1 D 2 Hose clamp ELVZ 11 17mm 1123 1 E 2 Quick coupling Female 5019 1 F 2 Quick coupling Male 5018 X 1 G 2 Hose 9 5x19 5 L 900 mm 12005 X CROSS TRAVERSE WITH 2x2 SUCTION PAD SUSPENSION SET Art no 408501 A B C D E...

Page 59: ...6 A B C D E F G 1 X Recommended spare part CROSS TRAVERSE SET Art no 408010 A B C D E F G 1 Pict Quan Description Type Art no A 1 A 4 2 ear hoseclamp Rnd 17 20mm 12004 1 B 4 Hose clamp ELVZ 11 17mm 1123 1 C 4 Quick coupling female hose Ø 9mm NW 7 2 5019 X 1 D 4 Quic coupling male thread G1 2 NW 7 2 5072 X 1 E 4 Fiber ring G1 2 5010 1 F 4 Hose 9 5x19 5 L 650 mm 12005 1 G Pict Quan Description Type ...

Page 60: ...C D E F G 1 X Recommended spare part SUCTION PADS WITH SUSPENSION SP1 90X550 S2 ART NO 408061 A B C D E F G 1 X Recommended spare part Pict Quan Description Type Art no A 1 A 2 Spring cotter 3 5 double 1007 1 B 2 Securing pin with cable Ø16x120 Lc 400 408015 1 C 2 Hose coupling Ø 9 G1 4 5002 1 D 2 Seal S2 1180 408028 x 1 E 2 Suction pad SP1 150x490 S2 408024 x Pict Quan Description Type Art no A 1...

Page 61: ...______________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com X Recommended spare part PANEL SECURING STRAP WITH SLING 30 270 100 Art no 17003 Panel securing strap with hook 30 270 30 Art no 17004 FALLING SAFETY DEVICE SET FS4 Art no 408007 A B C D E F G 1 Pict Quan Description Type Art no A 1 A 2 Safety strap SWL 500kg L 3000 17009 x 1 B 2 Assembly pivoting c...

Page 62: ...vac com TRANSPORT WHEEL SET Art no 408011 A B C D E F G 1 X Recommended spare part X Recommended spare part Pict Quan Description Type Art no A 1 A 2 Spring cotter 3 55mm double 1007 1 B 2 Securing pin with cable Ø16x120 Lc 400 408015 1 C 2 Wheel Ø160x40 39003 1 D TRANSPORT FRAME Art no 408012 A B C D E F G 1 Pict Quan Description Type Art no A 1 A 1 Spring cotter 3 5mm double 1007 1 B 1 Securing ...

Page 63: ...k pad W x L seal SP1 70x570 S1 1180 80 40 402092 408025 A B S2 SP1 90x550 S1 S2 S3 S6 1180 120 60 402087 408020 A B C E SP1 110x530 S1 S2 S3 S6 1180 150 75 402502 264116 A B C E SP1 150x490 S1 S2 S4 1180 200 100 408023 408024 A B D Fhor Horizontal lifting capacity at 0 6 bar vacuum level with 2 fold safety margin Fver Vertical lifting capacity at 0 6 bar vacuum level with 2 fold safety margin Rema...

Page 64: ...60 E info viavac com I www viavac com S1 Sealing ring 1 for sandwich roof panels 15x36 type L seal art no remark S1 680 680 400117 A S1 980 980 402033 A S1 1180 1180 408027 A Remark A Sealing ring for suction pad groove 15x15mm compensates up to 5mm profiling S2 Sealing ring 2 for sandwich wall panels 15x32 type L seal art no remark S2 980 980 402041 A S2 1180 1180 408028 A S2 1470 1470 402034 A R...

Page 65: ...VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com Remark A Sealing ring for suction pad groove 15x15mm for roof tray s type 106 153 158 Remark A Sealing ring for suction pad groove 15x15mm for roof tray s type 135 S3 Sealing ring 3 for roof tray s type L seal art no remark S3 980 980 402500 A S3 1180 1180 402501 A S4 Sealing ring 4 for roof tray s type L seal art no rema...

Page 66: ...________________________________ 32 ___________________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com Remark A SAB type 106 new S6 Sealing ring 6 for roof tray s type L seal art no remark S6 980 980 402505 A S6 1180 1180 402506 A ...

Page 67: ..._______________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com C 11 Maintenance record Data should be filled in with clear handwriting page 1 of 2 Name and address of inspection company Data concerning inspection delivery modification or repair Inspection date Company stamp and or signature of expert ...

Page 68: ...____________________________________________________________________________ VIAVAC vacuum lifting BV T 31 348 449 660 E info viavac com I www viavac com Data should be written with clear handwriting page 2 of 2 Name and address of inspection company Data concerning inspection delivery modification or repair Inspection date Company stamp and or signature of expert ...

Page 69: ...ded Added Added Added Added Added Added Added Inspection and maintenance topics CB 4 1 Cable remote control and radio remote control Max wind speeds Ajustments when use at altitudes above 1200mtr Reduced lifting capacity at altitudes above 500 meter Configurations R8000 2600 K8 R9800 2600 K8 Configurations R15200 6200 K8K16 R17000 6200 98 K8K16 C4 B3 B3 B6 B3 B3 B6 B6 AdG 01 03 2014 Added Configur...

Reviews: