  98MANAL359   Rev. F   3/21/17 

 

 

 

PRODUCT OVERVIEW 

 

All information contained in this document is representative of a standard Model 359.  If the product you ordered has special requirements or 

modifications, refer to the Laser Marked information on the product and your purchase order for possible alteration to the product’s 

configuration.  Failure to verify product configuration before installation may cause permanent product damage and in most cases, void the 

manufacturer’s product warranty.  If you are unsure or have questions about your product, please contact our Application Engineers for 

assistance. 

 

Remove and retain all instruction manuals and performance certificates that are shipped with the product.  These documents provide important 

information on the product’s calibration, operation, safety precautions, recommended maintenance, re-calibration requirements, repair service 

instructions and warranty information.  These documents are updated from time to time as changes to the product occur and should be reviewed 

at receipt so that proper and safe installation can occur. 

 

Specifications: 

Connection Diagrams: 

Output:  4-20 mA  

Single Transmitter 

Multiple Transmitters 

 

 

 

Sensor Construction:  Oil-Filled Silicon 

 

 

 

 

 

Wetted Parts:  316 LSS 

 

 

 

 

 

Electrical Mating Connection:  Acceptable 18AWG 

wire termination connection - 1/2” NPT (M) 

 

 

 

 

 

Electrical  Connections:  

Red:  + Signal 

Black:  - Signal  

Green Wire:   Case Ground 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Adapter Installation 

 

 

 

 

Typical Tank Installation 

 

 

Type 

‘L’ 

‘M’ 

Size Code 

Short 

Long 

Standard 

7.38 

13.06 
10.81 

2.14 
8.79 
6.54 

HD 
HE 

 

 

 

 

 

Summary of Contents for 359

Page 1: ... F 3 21 17 MODEL 359 SANITARY PRESSURE TRANSMITTER INSTALLATION MANUAL 199 Fire Tower Drive Tonawanda NY 14150 Toll Free 1 800 688 0030 International 716 629 3800 Fax 716 693 9162 www viatran com solutions viatran com ...

Page 2: ...e certificates that are shipped with the product These documents provide important information on the product s calibration operation safety precautions recommended maintenance re calibration requirements repair service instructions and warranty information These documents are updated from time to time as changes to the product occur and should be reviewed at receipt so that proper and safe instal...

Page 3: ...d in a process tank or piping by the customer 9 The mounting for the Model 359 Tank Spud shall have the flats of the shell aligned so as to allow for leak detection of the tank mounting 10 This product utilizes a fill fluid DC 200 CAS 63148 62 9 and has been determined to be non toxic 11 Adapters for Model 359 in general are not 3A approved Customer must ensure that the installation meets the requ...

Page 4: ... Tank Adapters Tank Shell Receiver Tank Shell Bezel Tank Plugs PREVENTATIVE MAINTENANCE Note This checklist should be followed each time a transmitter requires preventative maintenance Depending on product usage cycle all maintenance should be done on a schedule that is reflective of the application 1 Cleaning in place is the recommended process that should be performed as the system or process pe...

Page 5: ...s perceived to be exhibiting problems it can be returned to Viatran for analysis and or repair It is suggested that only Viatran personnel attempt repair of the product Any damage resulting from customer disassembly would result in a loss of coverage under the warranty policy All Viatran products are able to be repaired at minimal cost if simple cleaning and precautions are taken in the handling a...

Reviews: