3
‐
18
1141780,
Rev
002vx
MEOLink
User
Manual
(0.20,
0.25,
or
0.35
rolloff)
in
the
Matched
Filter
field.
Then
in
the
Custom
Filter
File
field,
select
Enable.
See
Section
3.2.5.2
.
2.1.6
Restoring
Factory
Defaults
Restoring
factory
defaults
is
supported
in
releases
on/after
03.00.05.
To
restore
factory
defaults,
Depress
the
RESTORE
button
located
on
the
rear
panel
of
the
MEOLink
Modem
for
approximately
15
seconds,
until
the
4
sets
of
DATA
Ethernet
lights
(J8
–J11)
flash
on.
After
several
more
seconds
those
same
lights
will
flash
for
5
seconds
and
the
modem
will
reboot.
When
the
modem
comes
up,
the
EEPROM
parameters
containing
the
IP
addresses
will
be
restored
to
the
settings
specified
in
Section
2.1.4
,
and
The
database
will
be
reset
to
the
factory
defaults
of
the
release
burned
into
Flash,
or
that
of
the
TFTP
Boot
server
if
it
matches
the
default
addressing.
3
MEOLINK
MODEM
OPERATIONS
3.1
Key
Features
3.1.1
LED
The
following
are
the
expected
Front
Panel
LED
displays
at
power
up:
1)
LED
are
all
on
at
power
up.
2)
Demod1,
Demod2,
Mod,
External
Ref,
Test
will
be
off
after
HOST
FPGA
is
loaded
and
taken
out
of
reset.
3)
Three
fan
fault
LED
will
be
off
after
FAN
check
passes
4)
Alarm
and
Fault
LED
will
be
off
when
POST
passes.
Standard
operation
conditions
for
the
LEDs
are
listed
in
Table
2.
3.1.2
Ethernet
Port
Selection
3.1.2.1
Data
Plane
Ethernet
Ports
There
are
four
Data
Plane
Ethernet
port
interfaces.
The
two
Primaries
are
PRI
A
and
PRI
B.
The
two
Secondaries
are
SEC
A
and
SEC
B.
The
operator
may
select
either
Primaries
or
Secondaries.
The
pair
with
the
greatest
number
of
active
links
will
be
preferred
and
activated.
3.1.2.2
Control
Plane
Ethernet
Ports
If
bonding
is
disabled,
only
the
Primary
port
will
remain
active.
If
bonding
is
enabled,
then
the
following
applies:
Startup
uses
the
Primary
Port
as
the
active
port.
If
the
active
port
is
down,
the
second
port
is
configured
and
made
active.
Summary of Contents for MEOLink
Page 1: ...MEOLink Modem User Manual ViaSat Document No 1141780 Rev 002v4 ...
Page 8: ...vi 1141780 Rev 002vx MEOLink User Manual ...
Page 14: ...1 6 1141780 Rev 002vx MEOLink User Manual Figure 3 MEOLink Physical Dimensions inches ...
Page 36: ...3 28 1141780 Rev 002vx MEOLink User Manual Figure 31 Sites Configuration Screen ...
Page 41: ...1141780 Rev 002vx 3 33 MEOLink User Manual Figure 36 Dashboard Status Screen ...
Page 46: ...3 38 1141780 Rev 002vx MEOLink User Manual Figure 43 Ethernet Port Metrics Screen ...
Page 47: ...1141780 Rev 002vx 3 39 MEOLink User Manual Figure 44 Ingress Egress Buffer Metrics Screen ...
Page 49: ...1141780 Rev 002vx 3 41 MEOLink User Manual Figure 46 Scheduler Metrics Screen ...
Page 51: ...1141780 Rev 002vx 3 43 MEOLink User Manual Figure 48 Demodulator Metrics Screen ...
Page 57: ...1141780 Rev 002vx 3 49 MEOLink User Manual ...
Page 58: ...3 50 1141780 Rev 002vx MEOLink User Manual ...
Page 59: ...1141780 Rev 002vx 3 51 MEOLink User Manual ...
Page 61: ...1141780 Rev 002vx 3 53 MEOLink User Manual ...
Page 62: ...3 54 1141780 Rev 002vx MEOLink User Manual ...
Page 68: ...3 60 1141780 Rev 002vx MEOLink User Manual 3 2 12 MEOLink Modem Help ...