51
CPU
F
EATURE
Thermal Management
This item sets CPU’s thermal control rule to protect CPU from overheat.
Settings
Description
Thermal Monitor 1
On-die throtting
Thermal Monitor 2
Ratio & VID transition
Thermal Monitor 3
Dynamic Ratio & VID transition
Disabled
Disable the thermal monitor
Thermal Monitor Bus Ratio
This item sets the frequency (bus ratio) of the throttled
performance that will be initiated when one on die sensor goes
from not hot to hot.
Key in a DEC number.
Settings: [Min = 0, Max = 255]
Thermal Monitor Bus VID
This item sets the voltage of the throttled performance that will be
initiated when the on die sensor goes from not hot to hot.
Settings: [0.700V, 0.716V, 0.732V, 0.748V, 0.764V, 0.780V, 0.796V,
0.812V, 0.828V, 0.844V, 0.860V, 0.876V, 0.892V, 0.908V, 0.924V,
0.940V, 0.956V, 0.972V, 0.988V, 1.004V, 1.020V, 1.036V, 1.052V,
1.068V, 1.084V, 1.100V, 1.116V, 1.132V, 1.148V, 1.164V, 1.180V,
1.196V, 1.212V, 1.228V, 1.244V, 1.260V, 1.276V, 1.292V, 1.308V,
1.324V, 1.340V, 1.356V, 1.372V, 1.388V, 1.404V, 1.420V, 1.436V,
1.452V, 1.468V, 1.484V, 1.500V, 1.516V, 1.532V, 1.548V, 1.564V,
1.580V, 1.596V, 1.612V, 1.628V, 1.644V, 1.660V, 1.676V, 1.692V,
1.708]
Summary of Contents for VIPRO VP7806
Page 10: ...X...
Page 11: ...1 1 Product Overview...
Page 18: ...8 VIPRO VP7806 DIMENSIONS Front View Back View...
Page 19: ...9 Right and Left View...
Page 22: ...12...
Page 24: ...14 INTRODUCTION OF I O LAYOUT Front View Layout Top View Layout...
Page 25: ...15 Bottom View Layout Right and Left View Layout...
Page 43: ...33 Step 4 Step 4 Step 4 Step 4 Secure the VIPRO VP7806 to the wall with four screws...
Page 51: ...41 4 BIOS Setup This chapter gives a detailed explanation of the BIOS setup functions...
Page 66: ...56 INTEGRATED PERIPHERALS...