EPIA-E900 User Manual
59
6.7.4.
Others Configuration
The Others Configuration screen can be used to set Watchdog Timer Configuration and Keyboard/Mouse
Wakeup Configuration.
Figure 63: Illustration of Others Configuration screen
6.7.4.1.
WATCHDOG Timer Enable
The WATCHDOG Timer Enable feature unlocks three other features that enable the BIOS to monitor the
state of the system. This feature has two options: enabled or disabled.
6.7.4.2.
WATCHDOG Timer RUN/STOP
The WATCHDOG Timer RUN/STOP feature controls if the WATCHDOG timer is active or dormant. This
feature has two options: stop and run.
6.7.4.3.
WATCHDOG Timer ACTION
The WATCHDOG Timer ACTION feature determines the action the WATCHDOG timer should take if the
timer counts down to zero. This feature has two options: reset and power off.
6.7.4.4.
WATCHDOG Timer COUNT
The WATCHDOG Timer COUNT feature determines the length of time the timer should count when the
timer is first triggered. This feature has four options: 72, 389, 706, and 1023 seconds.