background image

12

13

FLOATER

The Xclear Sieve floater must be filled with ± 500ml (±1 pint) of water to give it some 

counterweight. Fill the gap after filling by pushing the supplied rubber cap firmly into 

the hole.

MOUNTING THE FLOATER

The floater height on the supplied PVC pipe will determine the water level underneath 

the sieve screen when the pump is running. You can fasten the float with the supplied 

cable tie wrap. Before you secure the tie wrap, first test the correct height by just 

sticking the tie wrap through the holes of the float and PVC pipe! The highest position is 

for high flow rates (20-25m³/h), lowest position is for low flow rates (± 5m³/h). The PVC 

pipe has 4 holes.

MOUNTING THE INNER CONTAINER

The inner container must be sealed at the pipe connections with the 

supplied rubber foam rings. Fix them around the pipe connections of 

the inner container and lower the container with the float pipe into the 

Xclear Sieve. Firmly push the inner container into the pipe connections 

for maximum sealing results. You can check with your fingers on the 

inside of the container if the rubber rings are positioned correctly.

WASTE OUTLET

The Xclear gravity fed Sieve comes with a 63mm (2”) waste outlet that can be connected 

to the supplied 50mm slide valve with the supplied flexible socket.

PUMP CONNECTION

The Xclear Sieve comes with a flexible reducer fitting of 90 x 63mm (3” to 2”). The 

90mm/3”part fits on the pump outlet of the Xclear Sieve and the 63mm/2” part can be 

used to push a 63mm/2”pipe through towards the end of the Xclear gravity fed Sieve to 

prevent the pump from sucking in air bubbles.

MAINTENANCE

It is recommended to monitor the Xclear Sieve every day. Maintenance is very easy because of the waste outlet. In fact maintenance is about 

two operations:

    1. To remove the waste that is on the surface of the sieve (every day). 

2. To remove the waste that has gone into the profile wires of the sieve (only when necessary).

1.   Removing the waste that is on the surface of the sieve is very easy by opening the waste outlet and to rinse the waste away with a normal 

hose pipe. Another method to have water run over the screen is to open the adjustable weir (G) which will flood the screen with water. 

When the adjustable weir is in a fully open position already because of the pump speed you can push it closed for a short while and open it 

again.

2.  To remove the waste that has gone into the profile wires of the sieve you will need a hose pipe with a powerful spray nozzle or a high-

pressure machine. For this way of cleaning you have to place the sieve in an upright position or take the sieve out of the unit.

Note: when you use the sieve for the very first time the surface of the sieve can also be covered with a very thin film. Make 

sure you will clean the sieve very thorough with alcohol before using it.

TECHNICAL SPECIFICATIONS

SIZE

MATERIAL

EXTRA INFO

HOUSING

67 x 36 x 101 cm

PE

Lid included

INLET

110 mm outer Ø

PE

2 x 110 mm (4“) inlet

PUMP OUTLET

90 mm outer Ø

PE

Comes with 90/63mm (3 x 2”) flex. fitting

WASTE

63 mm

PVC Slidevalve

Comes with 63/50mm (2 x 1½”) flex. fitting

SIEVE BEND

450 x 345 mm

SS 304

300 micron

CAPACITY

Max. 25 m³/h

WEIGHT

±15 Kg. Incl. screen

Xclear is a trademark of VGE BV Son & Breugel www.vgebv.nl copyright VGE BV version 1.01 2013

SIEVE 

GRAVITY FED

Summary of Contents for xclear SIEVE GRAVITY FED

Page 1: ...1 SIEVE GRAVITY FED...

Page 2: ...de Xclear Sieve komt INTRODUCTIE NL ZorgervoordatdeXclearSievewaterpasopeenvlakkeondergrondkomttestaan DebovensterandvandeXclearSievemoet1cm bovenhet maximalewaterniveaustaan Voordeaansluitingvanuitde...

Page 3: ...Het is zeer belangrijk de Xclear Sieve dagelijks te controleren op vervuiling Het onderhoud zelf is erg eenvoudig dankzij de handige vuilafvoer In principe bestaat het schoonhouden van de zeef uit 2 h...

Page 4: ...ilterelement durchstr mt werden die Wassertropfen gespalten und mit Sauerstoff angereichert FUNKTIONSWEISE DE Sorgen Sie daf r dass der Xclear Siebbogenfilter waagerecht steht Der obere Rand vom Siebb...

Page 5: ...ernen t glich 2 Den Schmutz zwischen den Siebelementen zu entfernen nur wenn n tig 1 Den Schmutz auf dem Sieb kann man ganz einfach entfernen wenn man den Schmutzablass ffnet und den Schmutz mit Hilfe...

Page 6: ...oxygen when it goes through the slots INTRODUCTION EN MakesuretheXclearSieveisonanequal level underground TheupperedgeoftheXclearSievemustbe1cmabovethemaximumwaterlevel Between the bottom drain and th...

Page 7: ...d Sieve to prevent the pump from sucking in air bubbles MAINTENANCE It is recommended to monitor the Xclear Sieve every day Maintenance is very easy because of the waste outlet In fact maintenance is...

Page 8: ...14 VGE B V Ekkersrijt 7408 5692 HK Son The Netherlands Tel 31 0 499 461 099 Fax 31 0 499 494 229 info vgebv nl www vgebv nl...

Reviews: