The Xclear gravity fed Sieve is a pre-filter to filter waste solids from the water. This technique is based upon the sieve-bend screen. A sieve 

bend screen consists of hundreds of sharp stainless steel profile wires with very small slot openings where the water can go through but the 

solids stay on the sieve bend (see picture).

XCLEAR GRAVITY FED SIEVE INSTALLATION INSTRUCTIONS

In practice it works as follows:

The water enters at 

A

 and will go upwards and fall over at 

B

. The water 

goes through the sieve bend (

C

) and the waste solids will slowly go down 

to the waste area (

D

). At the waste outlet of the filter (

E

) is a sliding valve 

to easily wash away the waste with water. When the water in the tank 

underneath the sieve-bend will not be pumped away fast enough the 

water will rise which makes the floater (

F

) go up. The float is connected 

to a pipe that will push down the bended plate (

G

) to reduce the 

incoming water flow. The pump will be connected to the pipe (

H

). This 

pipe and the water guide (

I

) will prevent the pump from sucking in air 

bubbles. An extra advantage of this pre-filter is that the water will be 

provided with extra oxygen, when it goes through the slots.

INTRODUCTION EN

Make sure the Xclear Sieve is on an equal, level, underground. The upper edge of the Xclear Sieve must be 1 cm above the maximum water level. 

Between the bottom drain and the Xclear Sieve we strongly advise you to use a slide valve to separate the Xclear Sieve from the pond when 

necessary.

INLETS

The inlets of the Xclear gravity fed Sieve are made of 110mm (4”) PE pipe 

on which you can use the supplied flexible boot fittings. Since the Xclear 

Sieve is made of PE you cannot make glue connections. The Xclear Sieve 

has 2 inlets of 110 mm (4”) of which one can be closed with the supplied 

flexible end cap.

Please read these instructions before you start installing. If you have some questions after reading this manual, please contact your Xclear Sieve 

dealer before you start installing to prevent mistakes. Gravity (pond fed), equal to the water level in a direct connection with the bottom drain 

(and/or skimmer). Below you see a schematic drawing of a possible gravity installation

Water

Waste solids

Pond

Skimmer

Pond Water Level

Bottom drain

Slide valve

 to flush the bottom drain direct to waste 

without going to the filter.

Valve

 in between the Xclear gravity fed Sieve and 

the pond to seal off the Xclear Sieve from the pond

NOTE: 

Make sure the edge of the Xclear gravity fed Sieve

is 1 cm higher than the maximum water level

UV-C unit

Pump

Filter

Summary of Contents for xclear SIEVE GRAVITY FED

Page 1: ...1 SIEVE GRAVITY FED...

Page 2: ...de Xclear Sieve komt INTRODUCTIE NL ZorgervoordatdeXclearSievewaterpasopeenvlakkeondergrondkomttestaan DebovensterandvandeXclearSievemoet1cm bovenhet maximalewaterniveaustaan Voordeaansluitingvanuitde...

Page 3: ...Het is zeer belangrijk de Xclear Sieve dagelijks te controleren op vervuiling Het onderhoud zelf is erg eenvoudig dankzij de handige vuilafvoer In principe bestaat het schoonhouden van de zeef uit 2 h...

Page 4: ...ilterelement durchstr mt werden die Wassertropfen gespalten und mit Sauerstoff angereichert FUNKTIONSWEISE DE Sorgen Sie daf r dass der Xclear Siebbogenfilter waagerecht steht Der obere Rand vom Siebb...

Page 5: ...ernen t glich 2 Den Schmutz zwischen den Siebelementen zu entfernen nur wenn n tig 1 Den Schmutz auf dem Sieb kann man ganz einfach entfernen wenn man den Schmutzablass ffnet und den Schmutz mit Hilfe...

Page 6: ...oxygen when it goes through the slots INTRODUCTION EN MakesuretheXclearSieveisonanequal level underground TheupperedgeoftheXclearSievemustbe1cmabovethemaximumwaterlevel Between the bottom drain and th...

Page 7: ...d Sieve to prevent the pump from sucking in air bubbles MAINTENANCE It is recommended to monitor the Xclear Sieve every day Maintenance is very easy because of the waste outlet In fact maintenance is...

Page 8: ...14 VGE B V Ekkersrijt 7408 5692 HK Son The Netherlands Tel 31 0 499 461 099 Fax 31 0 499 494 229 info vgebv nl www vgebv nl...

Reviews: