EN
12
| XCLEAR FLOW-MATIC MANUAL
ACTION
DISPLAY TEXT
DISPLAY FIGURE
BLUE ECO
(optioneel)
19
Pump on
Backwash 5/5
Rinse with water
Backwash 5/5
Rinse with
water
UAM
08:00
95. W
2040.RPM 00.0A
TIME
Default 2 min.
Adjustable 0,5 – 5 min.
20
Pump off
Backwash 5/5
Rinse with water
Backwash 5/5
Rinse with
water
UAM
08:00
0. W
0000.RPM 00.0A
TIME
21
Positioning valves
Filter mode Set valves
Filter mode
Set valves
UAM
08:00
0. W
0000.RPM 00.0A
TIME
22
Positioning valves
Filter mode
Valves set
Filter mode
Valves set
UAM
08:00
0. W
0000.RPM 00.0A
TIME
23
Pump on
Status menu
Status Menu
Nextbead wash
in 1 days
UAM
08:00
9. W
0800.RPM 00.0A
TIME
INSTELLINGEN
TOUCHSCREEN
OMSCHRIJVING
DISPLAY FIGURE
DISPLAY FIGURE
DEFAULT DISPLAY
Default display during
filter mode. Touching the
left or right arrow brings
you to ‘wash program’
and ‘settings’.
Status Menu
Nextbead wash
in 1 days
WASH PROGRAM
Touching this screen
starts the Backwash
procedure.
Wash program
Nextbead wash
SETTINGS MENU
Touching the left or right
arrow gives access to
various settings.
Settings menu
Nextbead wash
EN
XCLEAR FLOW-MATIC MANUAL |
13
SETTINGS
TOUCHSCREEN
DESCRIPTION
DISPLAY FIGURE
DISPLAY FIGURE
SETTINGS MENU
Use arrows to select
cleaning frequency; daily
up to every 30 days.
Settings
Wash beads every:
1 day(s)
ok
Up to
Settings
Wash beads every:
30 day(s)
ok
SETTINGS MENU
Use arrows to select rinse
with water duration; 30 or
90 seconds.
Settings
Rinse with water:
30 sec.
ok
Up to
Settings
Rinse with water:
90 sec.
ok
SETTINGS MENU
Rinse with air. Use arrows
to select blower durati-
on; 0,5 up to 3 minutes,
adjustable in 0,5 minute
steps.
Settings
Blower time:
0,5 min.
ok
Up to
Settings
Blower time:
3.0 min.
ok
SETTINGS MENU
Use arrows to select
backwash duration; 0,5
up to 5 minutes in 0,5
minute steps
Settings
Backwash time:
0.5 min.
ok
Up to
Settings
Backwash time:
5.0 min.
ok
SETTINGS MENU
Use arrows to select
rinse duration; 0,5 up to
5 minutes in 0,5 minute
steps (step 5/5).
Settings
Rinse time:
0.5 min.
ok
Up to
Settings
Rinse time:
3.0 min.
ok
SETTINGS MENU
Use arrows to select Blue
Eco pump speed during
Backwash in 5% steps.
Settings
Blue Eco - wash
10% power
ok
Up to
Settings
Blue Eco - wash
100% power
ok
SETTINGS MENU
Use arrows to select Blue
Eco pump speed during
Filtration in 5% steps.
Settings
Blue Eco - continu
10% power
ok
Up to
Settings
Blue Eco - continu
100% power
ok
MAINTENANCE AND DISASSEMBLY
Warning
- To reduce the risk of electric shock, the device must be switched off and completely
de-energized before starting maintenance or disassembly. Follow the manual instructions
during maintenance/ disassembly.
1. Disconnect the unions (2+3) and drain the water from the system.
2. Open the pipe clip of the stand and remove the stand from the system.
3. Maintenance of the automatic valves must be performed at least once a year. This can be done