background image

08

Turn on the power and wait for the pump to prime, which may take up to five (5) minutes. Priming 

time will depend on the vertical length of the suction lift and the horizontal length of thesuction pipe. 

If the pump does not prime within five minutes, stop the motor and determine the cause. Make sure all 

suction and discharge valves are open when the pump is running.See Troubleshooting Guide.

PRIMING

Fill strainer housing with water to suction pipe level. If water leakage occurs anywhere on the pump 

or filter, DO NOT start the pump. If no leakage occurs, stand at least 10 feet from the pump and/or 

filter and proceed with starting the pump. 

STORAGE

In order to keep the pump from the freeze in winter, please drain the pump properly:

• Keep the water level below the inlet of the pool.

• Pull out the drain plug from the pump strainer body and 

remove the strainer lid. 

• Disconnect pump from mounting pad, wiring system, and

piping system. 

• Once water is drained off from the pump, reassemble the 

strainer lid and drain plugs. 

• Place pump in a shady and dry area. 

Voltage from the power must be in the range from 90% to 110% of the motor nameplate rated 

voltage. Otherwise, the motor may overheat and result in overload tripping and reduced 

component life. 

Install, ground, bond, and wire motor in accordance with local or NEC requirements. 

The motor should be grounded permanently by connecting the ground terminal to the electrical service

ground.

Bond motor to pool structure. Bonding will connect all metal parts within and around the pool with 

a continuous wire. 

Bonding reduces the risk of current passing between bonded metal objects, which could potentially 

cause electrical shock if grounded or shorted.

If any problem is found on the pump, see the Troubleshooting Guide to determine the cause and 

contact the distributor to get spare parts for replacement. See Parts Guide.

SERVICING

Check the status of the pump regularly. Clean the strainer immediately if it is full of debris. Make 

sure the environment is ventilated enough for the motor to cool itself. 

Warning:

 

Stop the pump and release all pressure from the circulation system before servicing. 

Summary of Contents for VVPS215BUS

Page 1: ...USER MANUAL DUAL SPEED POOL PUMP ...

Page 2: ...eview the contents of this manual before attempting to operate the equipment This manual should be located where it can be easily referenced by all users of themachine NEED HELP CONTACT US Have product questions Need technical support Please feel free to contact us CustomerService vevor com ...

Page 3: ...4 Strainer body 5 Drain Plug 6 Diffuser O Ring 7 Diffuser 8 Impeller 9 Pump Casing O Ring 10 Pump Housing 11 Screw 12 Motor 13 Carrier 14 Shaft Seal ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY...

Page 4: ...water to return to the pool Remove pressure test plugs and or plugs used in winterization of the pool spa from the suction outlets Fail to do so will result in an increased potential for suction entrapment Connect only to a branch circuit protected by a ground fault circuit interrupter GFCI Before working on any electrical equipment turn off the power supply to the equipment Do not permit children...

Page 5: ... must be solid level rigid and vibration free WARNING This product should be installed and serviced by a qualified pool professional All electrical wiring must be in conformance with applicable local codes regulations and the National Electric Code NEC It is strongly advised to protect the electrical components from direct sunlight though this pump is designed for outdoor use If installed within a...

Page 6: ...05 THP 1 5 2 0 L 13 58 345mm 14 17 360mm ...

Page 7: ...e or neutral wire is compatible with terminal 1 or 3 Turn on the power and run the pump How to wire 115V Make sure the switch is at the 115V side Ground wire connects to the ground terminal Hot wire connects to terminal 1 or 3 a neutral wire connects to terminal 3 or 1 Either hot wire or neutral wire is compatible with terminal 1 or 3 Turn on the power and run the pump WARNING All electrical wirin...

Page 8: ...r the motor s voltage phase and cycle and that the wire size is adequate for the HP kW rating and distance from the power source Warning All electrical wiring must be performed by a licensed electrician Warning All electrical wiring must conform to local codes and NEC regulations Warning Use copper conductors only Recommended Wire Size 0 50 No 14 No 14 No 14 No 12 No 14 No 10 No 14 No 10 No 14 No ...

Page 9: ... pump reassemble the strainer lid and drain plugs Place pump in a shady and dry area Voltage from the power must be in the range from 90 to 110 of the motor nameplate rated voltage Otherwise the motor may overheat and result in overload tripping and reduced component life Install ground bond and wire motor in accordance with local or NEC requirements The motor should be grounded permanently by con...

Page 10: ...e fully open and not blocked that the pool water level is at a proper level and that the skimmer weir is not hung up or stuck on the skimmer wall Block off to determine if the pump will develop a vacuum You should have 5 6 of vacuum at the strainer cover You may be able to check by removing the skimmer basket and holding your hand over the bottom port with the skimmer full and pump running If no s...

Page 11: ... pool and unrestricted discharge return lines Correct suction condition or throttle return lines if practical NOISY PUMP Vibration due to improper mounting etc Put a rubber pad under metal mounting feet Foreign matter in the pump housing Loose stones debris hitting the impeller could be the cause remove any above Motor bearings noisy from normal wear rust overheating or concentration of chemicals ...

Page 12: ...E mail CustomerService vevor com ...