05

Lights off

Lights off

Lights off

Lights off

/

Lights off

Blinks

3 times

every 2

seconds

Blinks

4 times

every 2

seconds

Blinks

5 times

every 2

seconds

Blinks

6 times

every 2

seconds.

Lights on

Blinks 8

times

every 2

seconds

Overvoltage 

Leakage

Overcurrent

Power Plug /

Circuit board

Over-heat

PE wire is

not connected

to ground

Power-on

Self-test

failed

When the voltage is no lower

than 270V±10V for 0.1 second,

the power output will be
stopped. When the voltage

drops to 254V±10V, charging
will start again after a 5-second

delay. "
When the leakage current is no
lower than 25±5mA, the relay

will be "off" (the response time

is <100mS). When the failure is
eliminated, the charger must be
powered on again to continue
charging.
1. When the current is more
than the "Stage1 Fixed

Overcurrent Value" but no more

than the "Stage2 Fixed

Overcurrent Value" for 5
seconds, the relay will be "off";

after 10 seconds, the relay will
be "on" again. If this overcurrent
situation occurs again, the relay

will be "off" again. After 3 times

of repeats, the failure light will
be on, and the charging is over.
The charger must be 
re-powered on to continue
charging. "2. When the current
is greater than the "Stage2

Fixed Overcurrent Value" for 1
second, the relay will be "off",

the failure light will be on, and
charging will be over. It must be
powered on again to continue
charging. "
When the temperature of the
power plug or circuit board is

more than 85℃ for 2 seconds,
the relay will be "off". It must

wait for the temperature to

drop below 65℃ for 2 seconds

to return to normal working.

Charging is allowed, but the
warning light will be "red" (no
blinking) all the time.

If the charger is faulty, the

relay will be "off" and the
charger will report the need

for repair.