04

Troubleshooting

Blinks once

Keeps

blinking

fastly

Keeps

blinking

slowly and

regularly

Lights on

Lights off

Lights off

LED Light 1 

(Green)

Blinks once

Lights off

Lights off

Lights off

Blinks once

every 2

seconds

Blinks twice

every 2

seconds

LED Light 2

 (Red)

Initial Status

To Be

Connected

Normal

Charging

End of

Charging

Abnormal

Communication

Undervoltage

Functions

Power on or reset. The relay

is "off".

The voltage of Detection Point 1

is 12V, and the relay is “off”.

The voltage of Detection Point 1

is 6V, and the relay is “on”.

The voltage of Detection Point 1

is 9V, and the relay is “off”.

The voltage of Detection Point 1
is abnormal (that is, the voltage
value is not one of the following

values: [6±0.8]V, [9±0.8]V,
[12±0.8]V), the charger enters

the protection status. When the
voltage at Detection Point 1 is
back to normal, the charger will
return to its normal working
state.
When the voltage is no more

than 75V±10V for 0.1 second,

the power output will be
stopped. When the voltage rises

to 90V±10V, the charging system
will start again after a 5-second

delay.

Definition

Stop Charging

1.  Disconnect the Type 1 plug from the vehicle inlet

Figure 4

.

2.  Disconnect the power plug from the outlet

Figure 5

.

3.  Replace the charger plug dust cap and store the charger unit in the bag

provided, in a dry place

Figure 6

.

5

4

6

Reviews: