49
6
Lubrication system
With the engine still at operating tempera-
ture: (If not, run the engine until warm,
then turn off.)
Replace the oil filter and change the
engine oil; use oil with protective proper-
ties. See page 65.
Raw water cooling system
Close the seacock before removing the lid
of the water strainer. If necessary, clean
the raw water strainer.
Pour 1 litre (1/4 Imp.gal.) of anti-freeze into
the water strainer and run the engine until
the anti-freeze has disappeared into the
cooling system.
Take care that no anti-freeze is spilled into
the waterway (anti-freeze is poisonous).
Check the seal between the lid and hous-
ing after cleaning and re-assembling the
strainer.
An improperly sealed lid will result in air
sucked in by the raw water pump which
again will result in overheating of the
engine.
Winter lay-up
Winter storage procedure
VD01010
VD00125