![Vetus M2.06 Operation Manual Download Page 37](http://html1.mh-extra.com/html/vetus/m2-06/m2-06_operation-manual_1010393037.webp)
35
5
Adjusting valve clearance
Cylinders are numbered consecutively,
beginning at the front end.
2-
CILINDER ENGINE
• Check valve clearance at cylinder 1 and
adjust if necessary.
• Rotate the crankshaft 180° clockwise
and check valve clearance at cylin-
der 2.
3-
CILINDER ENGINE
• Check valve clearance at cylinder 1 and
adjust if necessary.
• Rotate the crankshaft 240° clockwise
and check valve clearance at cylin-
der 3.
• Again rotate the crankshaft 240° and
check valve clearance at cylinder 2.
Checking valve clearance
Every 500 operating hours.
Maintenance
V
ALVE CLEARANCE
: I
NLET
0.25 mm (0.010”)
E
XHAUST
0.25 mm (0.010”)
VD01016
10
VD00153
VD00152