14
090123.01
Combined battery charger / battery splitter BCS1225, BCS1245, BCS2425, BCS2445
7 Technical details
Type:
BCS1225
BCS1245
BCS2425
BCS2445
Supply voltage:
230 Volt or 115 Volt (± 15%) internally adjustable
Frequency range::
50 of 60 Hz (± 10%) cat. II
Power consumption:
350 W
650 W
800 W
1300 W
Nominal current at 230 Volt:
1.8 A
2.7 A
4 A
6.7 A
at 115 Volt:
3.6 A
5.4 A
8 A
13.4 A
Battery voltage, nominal:
12 V
24 V
Charging voltage
Boost / Float:
Boost / Float:
- fluid filled batteries
14.1 V / 13.4 V
28.2 V / 26.8 V
- gel filled batteries
14.5 V / 13.8 V
29.0 V / 27.6 V
- deep cycle batteries
14.4 V / 14.0 V
28.8 V / 28.0 V
- AGM batteries
14.3 V / 13.4 V
28.6 V / 26.8 V
Charging current, maximum (± 5%) Charger:
25 A
45 A
25 A
45 A
Charging current, maximum (± 5%) Alternator:
125 A
Voltage drop diode splitter
0.1 V @ 20 A
Charging characteristic:
IIUoU, limited charging current, charging current, (equalise),
maintenance current (float)
Number of isolated outputs:
3
Suitable for a battery capacity in Ah, at a charging time of 11 to 14 hours:
- fluid filled batteries
175 - 250
270 - 440
200 - 300
350 - 500
- gel filled batteries
130 - 170
200 - 250
150 - 200
250 - 325
- deep cycle batteries
150 - 200
200 - 270
150 - 200
300 - 400
- AGM batteries
150 - 200
250 - 400
175 - 270
325 - 440
Adjustable for battery type:
Fluid filled / Gel filled / Deep cycle / AGM
Protection
Mains Under voltage
115 V I/P - < 80 V , 230 V I/P - < 180 V
Battery Over voltage
> 15,5 V
> 31 V
High temperature
Charger being at a too high temperature
Reverse polarity
Against wrong connection plus and minus of the batteries
Short Circuit
Output (Only for battery charger)
Fuse, mains
Glass fuse ‘Time Lag (T)’ (delayed) for the size of the fuses
see ‘10 Connection Drawings’
Fuse, batterry
Strip fuse 32 V, for the size of the fuses see ‘10 Connection Drawings’
Audible alarm
For battery reverse polarity warning
Indicators
Mains ON, Charger ON, Boost ,Battery over voltage, Over temperature,
Output fuse blown, Rev. polarity
Control
Mains on/off switch
Ambient temperature,
- during use:
- 10 ˚C tot +50 ˚C
- during storage:
- 20 ˚C tot +70 ˚C
Forced air cooling, number of fans:
1
2
2
2
Relative humidity:
10 to 90% condense free
Protection level:
IP20
Dimensions [mm]:
300 x 245 x 115
330 x 256 x 115
330 x 256 x 115
370 x 310 x 115
Weight :
1.5 kg
4.5 kg
3.5 kg
4.5 kg