43
02/2021
VETRON 5064 Welding Machine
04. COMMISSIONING & WELDING
16.
ERROR MESSAGES DURING WELDING
-2-2
DISPLAY
STEP
SOLUTION
»
ERROR MASSAGES
E20
Foot motor
Cable broken, bad connection, Stepdriver
multifunction
Restart, check cables
E21
Pressure motor
E22
Anvil motor
E23
Sonotrode motor
E25
GEN. UEBERLAST
Material welding no longer takes place or with
interruption
»
Check coaxial plug connection from genera-
tor to converter
»
Replace sonotrode unit (module)
E26
US.GEN.NO POW.
Power supply or control for generator is inter-
rupted
Check if:
»
Generator is turned on
»
Generator plug is inserted in the connector
strip below the table top
»
Check connector on generator including
adapter (interface). Replace interface if
necessary
»
Check generator connector on fan switch. If
necessary, replace fan switch or generator
connection cable
»
Check B2 plug connection to fan switch. If
necessary, replace fan switch or connection
cable.
»
Check B2 connection on the Vetron control
YSC-8340 and replace control or connection
cable if necessary.