background image

 

 

USER MANUAL 

 

Box 79 Industrivägen 3 

 

Tel. +46 (0)176-208920

 

Web     

www.vetek.com

  

76040 Väddö, Sverige  

 

Fax +46 (0)176-208929

  

Email   

[email protected]

  

 

Do not overload the instrument beyond its maximum capacity 

 

Do not apply loads abruptly. 

 

Do not press the keys with sharp or pointed objects 

 

Do not try to open the instrument. 

 

Do not remove seals from the instrument. 

 

Do not short-circuit the battery terminals 

 

Use only the power supply provided by Wunder. Before using it, make sure that the local mains voltage is compatible with the voltage of the adapter 

shown on the identification plate 

 

Regularly check the integrity of the instrument's power cord and make sure it does not come in contact with hot appliances 

 

Make sure that the power cord does not create obstruction hazards 

 

Unplug the instrument before cleaning it 

 

Do not place the instrument in water or other liquids 

 

Perform maintenance and subsequent metric verifications regularly 

 

 

4. THECHNICAL SPECIFICATION  

 

Model 

RB Basic  

RB Medium 

RB L 

RB with cable 

Capacity 

200kg 

300 kg 

200kg 

Division 

50-100g 

100 g 

50-100g 

MDD  OIML 

Class  III 

Unit weight 

kg 

Display 

LCD 1” con 5  digits attivi 

Function Key 

ON / ZERO / OFF, HOLD / BMI, TARA,  PRINT 

Power 

Rechargeable Batteries Pack-  Adapter 12 V -  2 A 

Operation temperature 

da 5°C a 35°C 

 

 

 

 

5. INDICATOR 

 

Summary of Contents for VBR-300

Page 1: ... PAGE 12 16 ASSEMBLY USE MECHANICAL TELESCOPIC HEIGHT METER OPTIONAL PAGE 13 17 THERMAL PRINTER OPTIONAL PAGE 15 By choosing the WUNDER mod RB or RB L or RB cable professional electronic scale you have purchased a high precision instrument Since over 40 years WUNDER has placed its experience at the service of health This instrument is compliant with national standards in hospitals and clinics with...

Page 2: ...ual 0470 MEDICAL CERTIFICATION METROLOGICAL CERTIFICATION AND APPROVAL FOR MEDICAL USE ACCURACY CLASS ASSISTANCE WARRANTY CERTIFICATE ATTENTION PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAILURE CAN DAMAGE THE PRODUCT WARNING PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAILURE CAN HARM THE OPERATOR OR PATIENT OR DAMAGE THE PRODUCT WASTE DISPOSAL TYPE B PARTS SUPPLIED BATTERY POWER INDICAT...

Page 3: ...dapter shown on the identification plate Regularly check the integrity of the instrument s power cord and make sure it does not come in contact with hot appliances Make sure that the power cord does not create obstruction hazards Unplug the instrument before cleaning it Do not place the instrument in water or other liquids Perform maintenance and subsequent metric verifications regularly 4 THECHNI...

Page 4: ...hold weighing result on the display determine stable weighing value Function BMI Tare un wanted weight Print uot data Function Display Symbols Stable symbol To indicate that the weight is stable Minor weight Weight under zero Zero symbols Weight is at zero point Low battery Battery need to charge or replaced 6 INSTALLATION ATTENTION ONLY FOR COLUMN SCALE After removing the instruments from the pac...

Page 5: ...inning with the top row with the flashing digit Press PRINT key after successful change to move to next step EX To input Dec 25 2008 8 00am Enter year Using TARE keys to decrease the value press HOLD key to move to next digit Press PRINT key after successful entry to move to next stage Enter date Using TARE keys to decrease the value press HOLD key to move to next digit Press PRINT key after succe...

Page 6: ... 0kg while switching power on Kindly press key to zero the scale which can be used at any time to zero the scale 7 4 Hold function The scale is provided with the integrated hold function to determine the average weight It enables people to be weighed accurately although they are not still on the scale platform Switch ON the scale using ON ZERO OFF key The diagnostic self check will be performed an...

Page 7: ...ght height and BMI value To release the locked weight on display simply press the HOLD BMI key again and the display will return to normal mode automatically 7 6 Tare function Tare allows the user to zero the instrument to cancel the weight of a container clothes from the reading of the instrument thus giving the true weight of the product person being tested Turn on the scale using key When displ...

Page 8: ... wunder it Set parameters of the scale interface on the connected device It is not possible to change the scale parameters Baud rate 9600 bps Parity check None Data length 8 bits Stop bit 1 bit Handshake RTS CTS Data code ASCII Serial RS232 Piedino Segnale 2 TXD 3 RXD 5 GND Connecting with PC Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communicat...

Page 9: ...to complete your setting Output Data When press the PRINT key to output data from scale to PC or an Optional Printer 9 SETTING SETUP Switch ON the scale and long press key for 3 seconds first SETUP and then A OFF will display successively AUTO OFF TIME SETUP This enables operator to select the auto turn OFF time of the device BUZZER ON OFF SETUP This enables operator to select beep sound ON OFF No...

Page 10: ...emains idle for a long period remove the batteries from the terminal During shipping make sure not to subject the instrument to blows or excessive mechanical stress In case of repairs or assistance contact your dealer or an authorised service centre contacting service2 wunder it or sales wunder it 12 CONFORMITY WUNDER MODEL RB or RB L or RB CABLE ELECTRONIC SCALE SERIAL N We hereby certify that th...

Page 11: ...cture at the end of its life Appropriate separate collection and sending the appliance for recycling treatment and environmentally compatible waste disposal contributes to avoid possible negative effects on the environment and health and favours the recycling of the materials the product is made of For more detailed information regarding available collection systems contact your local waste dispos...

Page 12: ...nce and of its improper use damage caused by an insufficient or inadequate electrical system or alterations resulting from environmental climatic or other types of conditions damage due to incorrect installation of the appliance and repairs carried out by unauthorised personnel Interventions at home for convenience controls or presumed defects Routine maintenance and that which can be considered n...

Page 13: ... Black abs support height meter 3 Screws A B C D E N 02 screws T E M5x16 N 02 slotted screws M5x25 N 01 Allen Screws M6x12 N 02 nuets ø 5 N 02 washers ø 5 4 Tools Tools Allen tools Picture 1 Assemble white metal support with abs black part white the screws B E Lock all with the screws D 1 1a Picture 2 2a behind the pole column assemble the white metal support with screws B Picture 2b the position ...

Page 14: ... 1 Press the black button and measuring height and push down 2 Position it horizontally 2 3 Lower the rod up to the point where the lever rests head touches the patient s head The height can be read at the point A 3 Position it horizontally 4 Lower the rod up to the point in which the blade rests head touches the patient s head The height can be read at point B Picture 3b The height rodi s ready f...

Page 15: ...vetek com 15 17 THERMAL PRINTER OPTIONAL Read this manual carefully before using the instrument 17 1 HOW TO USE YOUR PRINTER Connect the AC Adaptor and RS232 interface cable Press the I O button to power on the printer Platen Rollen Tear Bar Printer Button Status Indicator Roll Holder RS 232 connect Power Adattat ore ON OFF ...

Page 16: ...via the RS232 port and cable with the RA200 XL Press the PRINT key Print double language CHANGING THE PAPER ROLL The paper print roll on a PRINTER XL printer is changed as follows 1 Open the upper cover and position the paper roll so that it feeds in the right direction 2 Feed the end of the paper roll through the printer cover and close the cover The printer is ready to print ...

Page 17: ...rinting speed mm s 75 mm s Dimensions L x W x H 120 x 80 x 50mm Operating temperature 0 to 50 Operating humidity 20 to 85 no condensation Interface Conform to RS232 Voltage range adaptor only 12V 2A SHOCK HAZARD WARNING The printer and power supply should never be operated in a location where either one can get wet Personal injury could result MEDIA WARNING Always use high quality approved paper p...

Page 18: ... connections from AC outlet to the printer power supply Status indicator illuminated green light but the printer will not print Check interface cable connections from the scale to printer Make sure the top cover is closed and locked Printer paper jammed Reset the paper roll Please refer to CHANGING THE PAPER ROLL Status Indicator is flashing green Paper roll is out Reload a new source of paper rol...

Reviews: