SECTION 10 MESSAGE
10. 1 ERROR MESSAGE
Error code
describe
o-err
Overload
u-err
Under error of minus load
b-err
When an internal memory changes carelessly
1-err
When a standard weight is less than 10% of the capacity at the
time of the calibration by the external weight
2-err
At the time of failure when a display error exceeds 0.4% at the
time of the calibration by the external weight. When out of order.
l-err
When the piece weight is ligher than the countable piece weight
(piece weight less than capacity/60,000)
10. 2
Other Message
message
describe
func
At the time of the call of various functions and calibration function
cal
At the time of the start of the calibration by the external weight
on 0
Under the zero point directions at the time of the calibration by
external weight, and adjustment
on f.s
Under the amount directions of capacity at the time of the
calibration by the external weight, and adjustment
stop
When a key is pushed and stopped during calibration
When the key is pushed during sampling