Vetek LPWN-1530 Manual Download Page 7

 
Instruktion-LPWN Rev 1.2005 

Utskrift 2005-12-01 

 

 

 Användarmanual    

1. 

Power on while holding down MODE key. The scale will enter into function setting mode and 

CAL  

 

appears on the LCD display. Press PRINT key, the LCD display will show the scale model e.g.      

3 kg  

2. 

Press MODE key once again, the LCD display will show    

UON  

, which means the scale enters into 

weighing unit setting mode. Press PRINT key to select unit, press TARE key to enable (ON) or disable 
(OFF) the weighing unit. If the display shows    

ON kg 

, it means the unit shown will be used;  

OFF kg

 

means the unit shown will not be used. Press MODE key once again, the LCD display will show 

  Init   

,which means the scale enters into initial weighing unit setting mode; press TARE key to select initial unit 

setting. 
 

3. 

If the LCD display shows   

Init  g

 , it means “g” is the initial weighing unit when power on. Available 

units: kg, g, lb, lb-oz, jin, HK jin, Taiwan jin. 
 

4. 

Press MODE key once again, the LCD display will show     

Fil   

, which means the scale enters into 

filter setting mode; press down TARE , the display will show    

Fil  2

 , press TARE key again to switch the 

filter degree as 1, 2, 3 or 4. Level 4: Reaction is slower, effect on filtering is higher.  
 

5. 

Press MODE key once again, the LCD display will show    

Auto  

,which means the scale enters into 

auto power off setting mode; press TARE key to select the time of auto power off. 5, 10, 30, or 60 minutes 
means the lasting time value when the scale is at the non-tare zero point. In such mode, the scale will be 
powered off automatically after elapse of the set time. 
 

6. 

Press MODE key once again, the LCD display will show    

Ligh  

, which means the scale enters into 

backlight setting mode. Press TARE key to select setting, if the display shows   

OFF  

, it means the 

backlight is off;    

ON   

 means the backlight is on;    

Auto  

 means auto backlight is on. 

 

7. 

Press MODE key once again, the LCD display will show    

Lit   

, press TARE key,    

d1  

  

will appear on the display, press TARE

 

key again to select zero tracking range. 0, 1, 2, 3, 4 or 5 can be 

selected (the bigger the number is, the larger zero tracking range is). 
 

8. 

Press MODE key once again, the LCD display will show   

BAud  

, which means the scale enters into 

baud rate setting mode; press TARE key to select the transmission rate of 2400, 4800, or 9600. 
 

9. 

Press MODE key once again, the LCD display will show   

RS232  

,which means the scale enters into 

printing mode setting mode, press TARE to select  

Prt Co 

 Prt St  

, or 

  Prt Pr  

 (Pr means data sent 

when key pressed; St means data sent automatically when stable symbol shown; Co means data sent 
continuously). 
 

10. 

Press MODE key once again, the LCD display will show   

Print  

, which means the scale enters into 

printing mode setting mode, press TARE to select 

    PC  

   SH   

,or 

   EZ   

 

11. 

Press MODE key once again, the LCD display will show    

StAbl  

, which means the scale enters into 

printing stability judgement setting mode, press TARE key to select setting,    

YES  

means the data can be 

printed out by pressing PRINT key only in the stable mode;     

No  

means the stable mode will not be 

detected. Press MODE key to reset each function. Press ZERO key anytime when a function setting is 
completed. This will make the scale return to normal weighing mode. 

 

 

 

     

 

Vetek AB 

Box 79, Industriv. 3  760 40 Väddö 

 

Tel  0176 208 920 

Fax 0176 208 929  

                     

e-mail: [email protected]

                                 

     

  

www. vetek.se

                                 

      

Sida  

7

 

Summary of Contents for LPWN-1530

Page 1: ...ntrum av den inre ringen c Vågen bör alltid användas i en miljö som är så fri som möjligt från temperaturvariationer damm vibrationer drag fukt eller i korrosiv miljö Dessa faktorer påverkar hållbarhet och tillförlitlighet d För kontinuerlig drift anslut vågen till nätet med nätadaptern Vi rekommenderar att inte maskiner tex borrmaskiner används på samma säkring Vi rekommenderar att vågen ansluts ...

Page 2: ...behållaren med innehåll visas behållarens vikt så som negativt värde Tryck TARE för att återställa vågen Att räkna småsaker Detta är en våg för vanlig vägning men den har även en enkel räknefunktion Räkna enheter Vågen är utrustad med genomsnitt beräkning Denna funktion kompenserar för mindre viktskillnader i provvikterna Provvikterna bör väga minst 0 8 x vågensgradering Är vikterna för små för at...

Page 3: ...3 Easy to read LCD display 4 Counting function is applicable with backlight function 5 Tare range is unlimited 6 The case shell is made of ABS shockproof plastics stainless steel weighing pan is used for long term operation III ASSEMBLY A Models LPWN 1530 LPWN 7515 LPWN 1530K 1 Remove the protection copper screw 2 and then screw out the protection copper screw 1 2 Align the three hole aluminum col...

Page 4: ...on the LCD display charge the battery with AC power cord plug in the indicator of charge will light up in red when it becomes green means charge completed It takes about 8 hours to full charge the battery 2 Install the equipment on a level and stable surface 3 Do not install the equipment near the air conditioning or a vibrating machine 4 Install the equipment in an environment with steady tempera...

Page 5: ...E key to cancel the original tare Note This operation can only be performed in the stable mode 4 ZERO Press ZERO key and the screen will show zero 0 0000 press ZERO key in the tare mode the tare will be cancelled if the weight on the weighing pan is within the zero adjustment range the scale will be reset to zero 5 ON OFF Power switch Instruktion LPWN Rev 1 2005 Utskrift 2005 12 01 Användarmanual ...

Page 6: ... 1 2 3 4 Page 5 Item 4 Auto Auto power off OFF 5 10 30 60 Page 5 Item 5 Ligh Backlight OFF ON AUT Page 5 Item 6 Lit Zero point range 0 1 2 3 4 5 Page 5 Item 7 Baud RS 232 baud rate 2400 4800 9600 Page 5 Item 8 rS232 Printing mode Co St Pr Page 5 Item 9 Print External device PC SH EZ Page 5 Item 10 Stabl Printing stability Yes No Page 5 Item 11 Instruktion LPWN Rev 1 2005 Utskrift 2005 12 01 Använd...

Page 7: ...ime 6 Press MODE key once again the LCD display will show Ligh which means the scale enters into backlight setting mode Press TARE key to select setting if the display shows OFF it means the backlight is off ON means the backlight is on Auto means auto backlight is on 7 Press MODE key once again the LCD display will show Lit press TARE key d1 will appear on the display press TARE key again to sele...

Page 8: ...ARE key until On2 appears put weight of 2 3 full load on the weighing pan press TARE again On3 will appear on the display press TARE after putting weight of full load on the weighing pan and wait until PASS appears 3 Take off the weight press ZERO key to return to weighing mode B SINGLE POINT CALIBRATION 1 Power on while holding down MODE key to enter into setting mode the display shows CAL 2 Pres...

Page 9: ...object from weighing pan or malfunction of LOAD CELL Power on Err3 Check if A D or LOAD CELL malfunctions Power on Err4 Beep alert Switch power off and power on again or perform calibration Power on Battery symbol Charge the battery with power on Operating at normal weighing mode Err5 Checking if the weighing object is over the max capacity 9e Calibrating Err6 Change weight Instruktion LPWN Rev 1 ...

Page 10: ... N W 1 1375kg T W 0 0180kg G W 1 1555kg 2 g G N W g C R LF weight Example N W 1137 5g T W 18 0g G W 1155 5g 3 lb G N W l b C R LF weight Example N W 2 508lb T W 0 040lb G W 2 548lb 4 lb oz G N W l b o z C R L F weight lb Weight oz Example Instruktion LPWN Rev 1 2005 Utskrift 2005 12 01 Användarmanual Vetek AB Box 79 Industriv 3 760 40 Väddö Tel 0176 208 920 Fax 0176 208 929 e mail info vetek se ww...

Page 11: ...8G tl H G W 1 14 56G tl H 7 Taiwan jin G N W _ G t l T C R L F weight Example N W 1 14 32G tl T T W 0 0 48G tl T G W 1 14 80G tl T 8 pcs T o t a l p c s C R L F pcs Example Total 0 pcs 9 C R L F Example 0 G GROSS N NET T TARE Instruktion LPWN Rev 1 2005 Utskrift 2005 12 01 Användarmanual Vetek AB Box 79 Industriv 3 760 40 Väddö Tel 0176 208 920 Fax 0176 208 929 e mail info vetek se www vetek se Si...

Page 12: ...00 kg G W 1 6025 kg N W 1 1375 kg T W 0 0180 kg G W 1 1555 kg RS 232 Connector Signal Output Instruktion LPWN Rev 1 2005 Utskrift 2005 12 01 Användarmanual Vetek AB Box 79 Industriv 3 760 40 Väddö Tel 0176 208 920 Fax 0176 208 929 e mail info vetek se www vetek se Sida 12 ...