Vetek FR-H-100 Instruction Manual Download Page 4

                   

PREPARATION 

1.Installing batteries/Connecting the AC adaptor          

atteries 

  Battery                                        Remove the battery compartment  

  compartment                                   cover and insert six batteries(R6P/LR6 
                                               /AAsize) into the battery compartment, 
                                               taking extreme care that the polarities   
                                               plus and minus is observed. 
                                             

 

 

                               

  R6P/LR6/AA size 

                                      Dry batteries. 

  Battery compartment cover               (batteries are not included) 

 

AC adapter (optional) 

                                    

     Plug the AC adapter to the AC 

   AC adaptor                              

    

adapter socket on the side. 

   socket                                   

    

The AC input requirement could 

                                               be 110,120,220,230 or 240Volts 
                                               (50/60Hz) depending on the area 
                                               where used, so please verify that 
                                               the adaptor is correct                                           
                                        

 

2.Setting up the scale/balance 

 

,

!

 

CAUTION 

Avoid installing the scale/balance in direct sunlight, that may cause discoloration or 
malfunctions. Place your scale/balance on a firm weighing table so that the 
scale/balance is level. (The scale/balance will not perform accurately when it is not 
level.) 
 

Place the scale/balance on the firm surface that is flat and level for an accurate 
weighing. 

WEIGHING 

 

Before weighing 

Whenever possible, please allow the balance to warm up for 10 minutes after first 

turning to power on, so that the balance will function. Properly and accurately. 

 

Error messages 

EEEE:    Overload 

:     Low battery 

Calibration may be required before weighing. 

Read "CALIBRATION" first and if necessary, calibrate your scale/balance for 

accurate weighing. 

Weighing procedures 

1.

 

Press [ON/OFF] to turn on the balance. 

When power is turned on, all display segments appear on LCD for a few seconds and 

finally "0" will appear on the display. 

2.

 

Select the weighing unit with [UNIT]. 

Press 

[UNIT]

 to select a weighing unit, eg. "g"

" ct " 

" oz "

" tola " ……. 

Once the unit has been selected, the selected unit will be displayed to the weight value. 

3.

 

Start weighing   

If you do not use a container for weighing 

Verify the reading is "0". If not, press

 [ZERO] 

to display "0". 

Place objects on the weighing platform to weigh. 

When the reading becomes stable, the stable indicator is displayed. 

If you use a container for weighing 

Place an empty container on the platform. 

Wait for the stability indicator to be displayed and press 

[ZERO]

Place the objects to be weighed in the container. 

When the reading becomes stable, the stable indicator is displayed. 

FEATURES 

 

Auto shut off (optional).           

●   

Auto calibration 

 

Auto zero tracking                

● 

Auto backlight (optional) 

 

Low battery indication             

g/ct/oz/tola….. conversion(optional) 

 

Lager LCD Display               

● 

with counting function(optional)   

 

Large square weighting pan         

Net weight/stability indication 

 

1/120000&1/15000 division available   

 

FRH  RS-232 OUTPUT FORMAT 

 

 

Summary of Contents for FR-H-100

Page 1: ...ect ON activate the selected unit or OFF inactivate the selected unit press ZERO again to return to weighing mode 3 Switch the power to ON and than press ON OFF to turn on the scale The display shows F E 9 to 0 and than press PCS key to enter ZERO track function setting display shows x xd ZER press UNIT key to select ZERO track value 0 0d 0 5d 1 0d 1 5d 2 0d 3 0d press ZERO key to enter ZERO setti...

Page 2: ...Discharge the static electricity As example the method is to use the electrification prevention spray to spray it to both side of weighing platform 1 SPECIFICATIONS Model number Capacity Division FR H 100 100g 0 001g 0 005g FR H 200 200g 0 005g FR H 300 300g 0 005g 0 01g FR H 600 600g 0 01g 0 005g FR H 1000 1000g 0 01g 0 02g FR H 3000 3000g 0 05g 0 1g FR H 6000 6000g 0 1g 0 2g FR H 10000 10000g 0 ...

Page 3: ...ch can be setted according to your requirement 3 Calibration by the weight When you selected the calibration weight then place the calibration weight on platform Then press ZERO key the display return to the weight value Now the calibration is complete 4 Press ON OFF turn off the power press ON OFF turn on the power again place the weight on the platform to make sure whether weighing is correct if...

Page 4: ... accurately Error messages EEEE Overload Low battery Calibration may be required before weighing Read CALIBRATION first and if necessary calibrate your scale balance for accurate weighing Weighing procedures 1 Press ON OFF to turn on the balance When power is turned on all display segments appear on LCD for a few seconds and finally 0 will appear on the display 2 Select the weighing unit with UNIT...

Page 5: ...Bit 8 7 7 Parity None Even Odd Stop Bit 1 Code ASCII Data Format W WEIGHT M MESSAGE 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 HEA D DATA UNIT CR W M g C R L F Example 100 00g W 100 00g 500 00ct W 500 00ct Err 0 M over ...

Reviews: