Vetek FR-H-100 Instruction Manual Download Page 2

SAFETY PRECAUTIONS 

 

All safety messages are identified by the following the words "

WARNING

" and 

"CAUTION". These words mean the following: 

 

WARNING

 

Important information to alert you to a 

situation that might cause serious injury and 

damage to your property if instructions are 

not followed. 

CAUTION 

Important information that tells how to prevent 

damage to equipment. 

 

When using the scale/balance, the following safety precautions should always be 
followed. 
 

 

WARNING 

Use only the AC adaptor with the scale/balance. Other adaptor may cause 
damage. (AC adaptor is optional) 

 

 

CAUTION 

 

Avoid installing the scale/balance in direct sunlight, this may cause discoloration or 

malfunctions. 

 

Do not mix the type of batteries. Replace all other batteries at the same time. 

 

If the scale/balance is not to be used for a long period of time, remove all batteries 

from the battery compartment to avoid leakage which may cause damage to the 

instrument. 

 

Avoid overloading that could cause damage to the scale/balance. 

 

Do not drop water in the scale/balance that is not water-resistant. It causes damage, 

if inside of the scale/balance is wet. 

 

Matter charged static electricity could influence the weighing. Discharge the static 

electricity. As example, the method is to use the electrification prevention spray, to 

spray it to both side of weighing platform. 

 

       SPECIFICATIONS 

Model number 

Capacity 

Division 

    

FR-H

 -100 

   100g 

0.001g/0.005g 

    

FR-H

 -200 

   200g 

0.005g 

    

FR-H

 -300 

   300g 

0.005g/0.01g 

    

FR-H

 -600 

   600g 

0.01g/0.005g 

    

FR-H

 -1000 

   1000g 

0.01g/0.02g 

    

FR-H

 -3000 

    3000g 

0.05g/0.1g 

    

FR-H

 -6000 

    6000g 

0.1g/0.2g 

    

FR-H

 -10000 

   10000g 

0.2g/0.5g/1g 

    Platter 

φ

115mm or 170 x 180mm 

    Net/gross weight 

1350/1500g 

 

    

Package 

Standard carton: 34

×

22

×

14(cm

3

6 Units in one box: 

47.5

×

38.5

×

45(cm

3

)

 

Operating Temperature 

0-40

(32-104

   

Power source 

Batteries or AC/DC 

Adapter 9V/100mA (optional) 

 

Counting procedures 

1.Press [ON/OFF] to turn on the scale. 

Wait for "0" to appear on the display. 

2.Start the Count Procedure 

If necessary, press 

[ZERO]

 key to set the display to “0”. 

3.

 Press the 

[PCS]

 key to put the scale in PCS mode. ,the display will show P=X 

X ,press UNIT to select XX value (10 20 50 100),Place a given number of samples 
of an item on the pan (the Sample Size should be either 10

20

50 or 100 pieces). 

The weight of these samples will show on the display.     

4.

 Press the 

[PCS]

 key, the display will show “XX pcs”, then the scale will recall the 

sample size you selected and show the starting sample size on the display (you can 
now remove the samples if you want to return the scale to 0) 

5. 

Press the 

[PCS]

 key to return to the weighing mode

 

 

6

 

Summary of Contents for FR-H-100

Page 1: ...ect ON activate the selected unit or OFF inactivate the selected unit press ZERO again to return to weighing mode 3 Switch the power to ON and than press ON OFF to turn on the scale The display shows F E 9 to 0 and than press PCS key to enter ZERO track function setting display shows x xd ZER press UNIT key to select ZERO track value 0 0d 0 5d 1 0d 1 5d 2 0d 3 0d press ZERO key to enter ZERO setti...

Page 2: ...Discharge the static electricity As example the method is to use the electrification prevention spray to spray it to both side of weighing platform 1 SPECIFICATIONS Model number Capacity Division FR H 100 100g 0 001g 0 005g FR H 200 200g 0 005g FR H 300 300g 0 005g 0 01g FR H 600 600g 0 01g 0 005g FR H 1000 1000g 0 01g 0 02g FR H 3000 3000g 0 05g 0 1g FR H 6000 6000g 0 1g 0 2g FR H 10000 10000g 0 ...

Page 3: ...ch can be setted according to your requirement 3 Calibration by the weight When you selected the calibration weight then place the calibration weight on platform Then press ZERO key the display return to the weight value Now the calibration is complete 4 Press ON OFF turn off the power press ON OFF turn on the power again place the weight on the platform to make sure whether weighing is correct if...

Page 4: ... accurately Error messages EEEE Overload Low battery Calibration may be required before weighing Read CALIBRATION first and if necessary calibrate your scale balance for accurate weighing Weighing procedures 1 Press ON OFF to turn on the balance When power is turned on all display segments appear on LCD for a few seconds and finally 0 will appear on the display 2 Select the weighing unit with UNIT...

Page 5: ...Bit 8 7 7 Parity None Even Odd Stop Bit 1 Code ASCII Data Format W WEIGHT M MESSAGE 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 HEA D DATA UNIT CR W M g C R L F Example 100 00g W 100 00g 500 00ct W 500 00ct Err 0 M over ...