1. Not overloading. Not throw heavy things on the scale violently. The damage for overloading is

not within the range of guaranteed maintenance.

2. Don’t use sharp thing to operation the keyboard. If the rubber is damaged it will influence the

performance of waterproof.

3. keep the scale clean in order to weighing well.

4. There is a lead seal on the bottom of the scale. Users are not allowed to remove the seal. If the

seal is damaged the scale is not guaranteed for maintenance.

5.

a.

 You must charge the battery at least per 3 months when you don’t use the

scale for a long time.

b.

Please correctly connect line between adapter and battery, black to black,

red to red.

c.

If after charging the used time becomes short than often, please change a

new battery.

IV. NOTE

9.9 d-dP(choose single or dual display)

When menu displays d-dP,press [TARE] to enter,press [SET/0~9] to choose n or y, n is single 

display,y is dual display, Press [TARE] to confirm.

10. Tune LED lighting

On powering on, long time press [zero/on], it shows LC-,press [SET/0~9] to choose LU-1 or LU-

2,LU-1 is saving mode(commend),Press [TARE] to confirm.

CALIBRATION OF SS SCALE (VERSION 3S-5.3OR5.4)

A. Multi-point adjust:

1. Push the adjust key to switch on, the switch is on the bottom of the scale, locked with a seal.

.Press “ on/zero “ key, after a while start to adjust.

2. Press “set/0~9” and “ on/zero “ key the same time, choose weighing units-kg, lb or counting

function, press tare to confirm. Then the display shows “c”. “c” is the Max. capacity, press “set/0~9”

to choose c-600,c-1500,c-3000,c-6000,c-15H9(15kg),c-30H9(30kg) and press “tare” to confirm.

3. Now it displays 1/3 Max capacity, then display 0. (If is not 0, press “on/zero”)

4. Put the displayed weights on the centre of the plat, after it shows stable, press the “tare”,

it shows 2/3 Max capacity. Then put the displayed weight it displays Max capacity, put the

displayed weight. Press “tare”.

5. Now it shows c-0, “c” is flashing. Now change gravity. Press “ on/zero “ to add 1

internal number, Press “set/0~9” to reduce 1 internal number. 60000 internal number means the

max. capacity. Press “tare” to exit adjustment.

6. Push the adjust key to switch off.

B. One-point user ADJUST:

Push the adjust key to switch on. Press “tare” 3 seconds, display “CAL””0”. Press “tare” to confirm

zero. Put the Max capacity weight, after 5 seconds press “tare”, it shows CAEnd and exit

adjustment. Push the adjust key to switch off. NOTE: After changed loadcell or PCB, if you need

adjust but it shows “Err-0”, it means zero is not in the limited range. Then after power on please

press “tare” immediately, it will go into adjusting.

Summary of Contents for ACS-3S/NEW SU Series

Page 1: ...nic waterproof weighing counting scale New SU are plastic scales and 3S a stainless steel scale The scale is manufactured with advances computer controlled hi techniques It has the characteristics of satisfactory in performance accurate in weighing convenient for carrying cheap in price It is sturdy and durable and widely used in not only retail stores and weighing of ration packing of commodities...

Page 2: ...ing sounding bATLo The voltage is lower You can use a short while and charge immediately c _End Recharge is end Err 0 Overload zero of loadcell Please re adjust or change loadcell II Operation guide 1 Preparation Adjust the base foot watch the level make the pan in horizontal 2 Turn on or turn off 2 1 Turn on Press the ON ZERO key the ding sound it displays version No and the battery voltage level...

Page 3: ... supplied by a internal rechargeable lead acid battery 6V 4Ah When it shows bAtLo Please turn off and charge immediately The time of full charging is 12 hours 9 Set parameter Press SET 0 9 key 3 seconds to set Now show menu Press SET 0 9 continuous it displays rAngE set limit UnItS choose unit A oFF choose auto power off FILt set display mode ZEro set auto zero bUZZEr set buzzle d choose division ...

Page 4: ...0000 9 3 A oFF choose auto power off When menu displays A oFF press TARE to enter press SET 0 9 to choose n or y n is not auto power off y is after 10 minutes in zeroing auto off 9 4 Change display mode When it displays FILtX FILt1 means one step to display FILt2 means 3 4 steps to display FILt3 means 6 8 steps to display FILt4 means display is fast Press SET 0 9 to change press TARE to confirm an...

Page 5: ...oint adjust 1 Push the adjust key to switch on the switch is on the bottom of the scale locked with a seal Press on zero key after a while start to adjust 2 Press set 0 9 and on zero key the same time choose weighing units kg lb or counting function press tare to confirm Then the display shows c c is the Max capacity press set 0 9 to choose c 600 c 1500 c 3000 c 6000 c 15H9 15kg c 30H9 30kg and pr...

Reviews: