user manual
www.vetek.com
5
1. Not overloading. Not throw heavy things on the scale violently. The damage for overloading is
not within the range of guaranteed maintenance.
2. Don’t use sharp thing to operation the keyboard. If the rubber is damaged it will influence the
performance of waterproof.
3. keep the scale clean in order to weighing well.
4. There is a lead seal on the bottom of the scale. Users are not allowed to remove the seal. If the
seal is damaged the scale is not guaranteed for maintenance.
5.
a.
You must charge the battery at least per 3 months when you don’t use the
scale for a long time.
b.
Please correctly connect line between adapter and battery, black to black,
red to red.
c.
If after charging the used time becomes short than often, please change a
new battery.
IV. NOTE
9.9 d-dP(choose single or dual display)
When menu displays d-dP,press [TARE] to enter,press [SET/0~9] to choose n or y, n is single
display,y is dual display, Press [TARE] to confirm.
10. Tune LED lighting
On powering on, long time press [zero/on], it shows LC-,press [SET/0~9] to choose LU-1 or LU-
2,LU-1 is saving mode(commend),Press [TARE] to confirm.
CALIBRATION OF SS SCALE (VERSION 3S-5.3OR5.4)
A. Multi-point adjust:
1. Push the adjust key to switch on, the switch is on the bottom of the scale, locked with a seal.
.Press “ on/zero “ key, after a while start to adjust.
2. Press “set/0~9” and “ on/zero “ key the same time, choose weighing units-kg, lb or counting
function, press tare to confirm. Then the display shows “c”. “c” is the Max. capacity, press “set/0~9”
to choose c-600,c-1500,c-3000,c-6000,c-15H9(15kg),c-30H9(30kg) and press “tare” to confirm.
3. Now it displays 1/3 Max capacity, then display 0. (If is not 0, press “on/zero”)
4. Put the displayed weights on the centre of the plat, after it shows stable, press the “tare”,
it shows 2/3 Max capacity. Then put the displayed weight it displays Max capacity, put the
displayed weight. Press “tare”.
5. Now it shows c-0, “c” is flashing. Now change gravity. Press “ on/zero “ to add 1
internal number, Press “set/0~9” to reduce 1 internal number. 60000 internal number means the
max. capacity. Press “tare” to exit adjustment.
6. Push the adjust key to switch off.
B. One-point user ADJUST:
Push the adjust key to switch on. Press “tare” 3 seconds, display “CAL””0”. Press “tare” to confirm
zero. Put the Max capacity weight, after 5 seconds press “tare”, it shows CAEnd and exit
adjustment. Push the adjust key to switch off. NOTE: After changed loadcell or PCB, if you need
adjust but it shows “Err-0”, it means zero is not in the limited range. Then after power on please
press “tare” immediately, it will go into adjusting.