11-7-2 Turntable doesn’t stop after completing wrapping cycle
Condition:
a). Turntable has slowed down.
Check if LED M1 and LED Turntable Slow
Down are dark on PC board
KS-050202-KEY.
YES
Replace PC board KS-050201-MB.
NO
Check if LED M1 and LED Turntable Slow
Down are dark on PC board
KS-050202-KEY.
NO
Replace Proximity Switch PS1.
YES
Replace PC board KS-050201-MB. Check
if turntable has stooped.
YES
Replace Proximity Switch PS1.
NO
Replace Inverter IVR1.
11-8 LS1, LS2, LS2-1, LS2-2, PS1, PS2 and PH not operating normally on PC board
KS-050202-KEY
11-8 LS1, LS2, LS2-1, LS2-2, PS1,
PS2 and PH not operating norm ally on
PC board KS-050202-KEY
NO
Replace limit switches, photo switch
and proximity switches.
YES
Replace PC board KS-050202-KEY. Check
if normal operation resumes.
NO
Replace PC board KS-050201-MB.