F:\Manual\SM-1517R-110V-100514
14.05.2010.
- 59 -
11-10 Pre-stetch motor M3 hasn’t worked:
Condition:
a). LED M3 lights up on PC board KS-050202-KEY.
b). There’s AC110V at terminal R and S terminal on Inverter IVR3.
c). Power supply SP2 has worked normal. (Supply DC24V to proximity switch SPS1)
Check if there’s AC220V at outputs U,V
and U,W and V,W on Inverter IVR3.
YES
Replace Motor M3.
NO
Refer to Inverter IVR3, short between
terminal MI1 and DCM with a wire. Check i f
the display screen on Inverter changes and
motor M3 is working.
YES
Replace PC board KS-050201-MB.
NO
Refer to Inverter IVR3, short between
terminal MI1 and DCM with a wire. Check i f
the display screen on Inverter changes and
motor M3 is working.
NO
Replace Inverter IVR3.
Summary of Contents for SWA Series
Page 40: ...F Manual SM 1517R 110V 100514 14 05 2010 37 I I rn a N a a J r o N o or o 2...
Page 44: ...F Manual SM 1517R 110V 100514 14 05 2010 41 I ol 4 cl J f...
Page 70: ...F Manual SM 1517R 110V 100514 14 05 2010 67 12 3 1 Fig 14000 Bottom Plate Diagram 1...
Page 85: ...F Manual SM 1517R 110V 100514 14 05 2010 82 12 7 1 Fig 19100 Pre Stretch Unit Diagram 7 2 1...