Vestil EHLTX-3653-1-39 Instruction Manual Download Page 32

Operator’s Manual 

2/2/21 

EHLTX, MANUAL.DOCX 

 

Table of Contents

  

Copyright 2021, Vestil Manufacturing Corp. 

Page 

32

 of 

32

 

LIMITED WARRANTY 

Vestil Manufacturing Corporation (“Vestil”) warrants this product to be free of defects in material and workmanship during the 

warranty period. Our warranty obligation is to provide a replacement for a defective, original part covered by the warranty after we 
receive a proper request from the Warrantee (you) for warranty service. 

Who may request service? 

Only a warrantee may request service. You are a warrantee if you purchased the product from Vestil or from an authorized 

distributor AND Vestil has been fully paid. 

Definition of “original part”? 

An original part is a part used to make the product as shipped to the Warrantee. 

What is a “proper request”? 

A request for warranty service is proper if Vestil receives: 1) a photocopy of the Customer Invoice that displays the shipping 

date; AND 2) a written request for warranty service including your name and phone number. Send requests by one of the following 
methods: 
US Mail 
Vestil Manufacturing Corporation 
2999 North Wayne Street, PO Box 507 
Angola, IN 46703 

Fax 

(260) 665-1339 

Phone 

(260) 665-7586 

Email 

[email protected] 

Enter “Warranty service request” in subject field 

In the written request, list the parts believed to be defective and include the address where replacements should be delivered. 

After Vestil receives your request for warranty service, an authorized representative will contact you to determine whether your 
claim is covered by the warranty. Before providing warranty service, Vestil will require you to send the entire product, or just the 
defective part (or parts), to its facility in Angola, IN. 

What is covered under the warranty? 

The warranty covers defects in the following original, dynamic parts: motors, hydraulic pumps, motor controllers, and cylinders. 

It also covers defects in original parts that wear under normal usage conditions (“wearing parts”), such as bearings, hoses, wheels, 
seals, brushes, and batteries. 

How long is the warranty period? 

The warranty period for original dynamic components is 1 year. For wearing parts, the warranty period is 90 days. Both 

warranty periods begin on the date Vestil ships the product to the Warrantee. If the product was purchased from an authorized 
distributor, the periods begin when the distributor ships the product. Vestil may, at its sole discretion, extend a warranty period for 
products shipped from authorized distributors by up to 30 days to account for shipping time. 

If a defective part is covered by the warranty, what will Vestil do to correct the problem? 

Vestil will provide an appropriate replacement for any covered part. An authorized representative of Vestil will contact you to 

discuss your claim. 

What is not covered by the warranty? 

The Warrantee (you) are responsible for paying labor costs and freight costs to return the product to Vestil for warranty service. 

Events that automatically void this Limited Warranty. 

 

Misuse; 

 

Negligent assembly, installation, operation or repair; 

 

Installation/use in corrosive environments; 

 

Inadequate or improper maintenance; 

 

Damage sustained during shipping; 

 

Collisions or other accidents that damage the product; 

 

Unapproved modifications: Do not modify the product IN ANY WAY without first receiving written authorization from Vestil. 

Do any other warranties apply to the product? 

Vestil Manufacturing Corp. makes no other express warranties. All implied warranties are disclaimed to the extent allowed by 

law. Any implied warranty not disclaimed is limited in scope to the terms of this Limited Warranty. Vestil makes no warranty or 
representation that this product complies with any state or local design, performance, or safety code or standard. Noncompliance 
with any such code or standard is not a defect in material or workmanship. 

 

 

Summary of Contents for EHLTX-3653-1-39

Page 1: ...ransport If damage is discovered record a complete description of it on the bill of lading and file a claim with the carrier immediately If the product is undamaged discard the packaging NOTE The end...

Page 2: ...COULD result in MINOR or MODERATE injury Identifies practices likely to result in product property damage such as operation that might damage the product HAZARDS Vestil Manufacturing strives to ident...

Page 3: ...DO use an anti wear hydraulic oil with a viscosity grade of 150 SUS at 100 F ISO 32 cSt 40 C or Dexron non synthetic transmission fluid DO NOT use brake fluid or jack oils in the hydraulic system Con...

Page 4: ...2021 Vestil Manufacturing Corp Page 4 of 32 EXPLODED PART VIEWS AND BILLS OF MATERIAL EHLTX Top Level Bill of Materials ITEM DESCRIPTION 1 BASE ASSEMBLY 2 PLATFORM 3 PERIMETER TOE GUARD ASSEMBLY 4 POW...

Page 5: ...Operator s Manual 2 2 21 EHLTX MANUAL DOCX Table of Contents Copyright 2021 Vestil Manufacturing Corp Page 5 of 32...

Page 6: ...Operator s Manual 2 2 21 EHLTX MANUAL DOCX Table of Contents Copyright 2021 Vestil Manufacturing Corp Page 6 of 32...

Page 7: ...4 WELDMENT PIN ASSY FRAME HINGE 2 1 1 13 01 115 001 WASHER THRUST BEARING 1 1 8 ID 6 1 1 14 01 112 001 PIN CLEVIS CYLINDER W STOP BOSS 2 1 1 16 05 112 003 PIN ROLLER 2 1 1 17 26 112 002 PIN AXLE 2 1 1...

Page 8: ...Operator s Manual 2 2 21 EHLTX MANUAL DOCX Table of Contents Copyright 2021 Vestil Manufacturing Corp Page 8 of 32...

Page 9: ...Operator s Manual 2 2 21 EHLTX MANUAL DOCX Table of Contents Copyright 2021 Vestil Manufacturing Corp Page 9 of 32...

Page 10: ...ISSOR PIVOT 2 11 27 112 006 PIN CAM PIVOT 4 12 27 112 007 PIN CYL CAM 2 13 99 021 911 001 CYLINDER HYDRAULIC 2 1 2 X 8 1 2 RAM STYLE MACHINED END 2 14 22804 FLAT COUNTERSUNK HEAD ELEVATOR BOLT PLAIN F...

Page 11: ...T RUBBER HOUSING 4 2 4 7 TOE GUARD CONTACT FACTORY FOR YOUR SPECIFIC MODEL 4 3 01 015 017 TOE GUARD LIMIT SWITCH ACTUATOR 2 5 01 022 022 SWITCH LIMIT N C MICRO 2 6 01 145 010 SPECIALTY HARDWARE TOEGUA...

Page 12: ...ore any work is performed on the lift table Only qualified individuals trained to understand mechanical devices and their associated electrical and hydraulic circuits as well as the hazards associated...

Page 13: ...p Page 13 of 32 115 VAC Single Phase Electric Circuit Diagram 27124002 Rev B Note Overcurrent short circuit protection and disconnect must be provided by end user NOTE Pressure switch replaces limit s...

Page 14: ...Page 14 of 32 208 230 VAC Single Phase Electric Circuit Diagram 27124003 Rev B Note Overcurrent short circuit protection and disconnect must be provided by end user NOTE Pressure switch replaces limit...

Page 15: ...g Corp Page 15 of 32 Three Phase Electric Circuit Diagram 27124004 Rev B Note Overcurrent short circuit protection and disconnect must be provided by end user NOTE Pressure switch replaces limit switc...

Page 16: ...motors and for all 2 HP 5 5 HP and 6 5 HP three phase motors The two thermostat leads go to 1 the grounded side of the transformer secondary and 2 the motor relay coil Polarity across the thermostat l...

Page 17: ...he factory ITEM PART NO DESCRIPTION QTY 1 115 V 208 230V 99 135 003 MOTOR 3 4 HP 1PH 1725 RPM 56F 115 208 230 60HZ 1 230 460V 3 99 135 005 MOTOR 2 HP 3PH 1725 RPM 56F 208 230 460V 50 60HZ 2 115 V 208...

Page 18: ...27 010 MANIFOLD L H L 1 2 99 034 008 COIL WITH DIN CONNECTOR 1 3 99 144 008 O RING MANIFOLD 1 2 OD 1 4 99 144 009 O RING MANIFOLD 3 4 OD 1 5 99 153 006 VALVE PRESSURE RELIEF 210 BAR 1 6 99 153 011 CHE...

Page 19: ...s Section 12 6 Attaching ancillary equipment to the platform will lower its load capacity The installation shall comply with all applicable regulations for its location and use The end user is respons...

Page 20: ...nditions DO NOT operate an unsecured lift table A power supply and electrical disconnect matching the power unit s voltage and current requirements Refer to the lift table s data plate labels on the c...

Page 21: ...X 4753 1 39 EHLTX 4753 2 39 31 3 4 23 3 4 15 1 4 47 53 3 EHLTX 4756 1 39 EHLTX 4756 2 39 31 3 4 23 3 4 15 1 4 47 56 4 1 2 EHLTX 4760 1 39 EHLTX 4760 2 39 31 3 4 23 3 4 15 1 4 47 60 6 1 2 EHLTX 4853 1...

Page 22: ...form must be lowered and fully supported under its frame when moved Support the lift table with straps or forks that span the entire width or length of the base frame Remove the 4x4 wood dunnage from...

Page 23: ...n synthetic automatic transmission fluid 9 Clean up any debris or spilled oil Verify that all of the information safety and warning labels are in good condition ACCESSORIES Vestil offers table skirts...

Page 24: ...40 lb ARX RS 3642 3 42 3 1 4 36 1 2 N A 171 lb ARX RS 3642 5 42 4 1 2 36 1 2 N A 197 lb ARX RS 3642 5 5 42 5 1 2 36 1 2 N A 218 lb RECORD OF SATISFACTORY CONDITION After assembling and installing the...

Page 25: ...s lift table Loading the platform The load rating in pounds is shown on the machine data plate located on the hinged end of the platform This indicates the net capacity of the scissor lift table for a...

Page 26: ...form The EHLTX lift table is provided with hydraulic overload protection that will prevent it from raising a load in excess of its rated capacity The lowering speed is preset at the factory and will n...

Page 27: ...nspected by a qualified person Complete both the daily and monthly inspection items before releasing the lift table for regular use Daily inspection At the beginning of every shift a designated person...

Page 28: ...ifold assembly is part of the power unit attached to the end of the motor and pump 4 Remove the nut holding the solenoid coil item 2 right on the solenoid valve stem Remove the coil 2 then unscrew the...

Page 29: ...chanical devices electrical and hydraulic circuits and the hazards associated with them should attempt troubleshooting and repair of this equipment Consult the factory for any problems not addressed i...

Page 30: ...from system Fluid level in reservoir is low Add fluid Fluid should be 1 to 1 below the reservoir fill hole with the platform in the fully lowered position Platform won t lower Perimeter toe guard act...

Page 31: ...table when you first receive it as discussed in the Record of Satisfactory Condition section on p 24 Make sure that your record includes a photograph of each label Replace all labels that are or later...

Page 32: ...ulic pumps motor controllers and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and batteries How...

Reviews: