Operator’s Manual
2/2/21
EHLTX, MANUAL.DOCX
Copyright 2021, Vestil Manufacturing Corp.
Page
19
of
32
Hydraulic Schematic (01-125-008).
ITEM
PART NO.
DESCRIPTION
QTY
1
01-127-010
MANIFOLD, LHL
1
2
99-153-011
CHECK VALVE, SIZE 08,
NOSE-IN/SIDE-OUT
1
3
1.5 GPM
99-153-039
FLOW CONTROL, PRES.
COMP.
1
2.0 GPM
99-153-040
4
99-153-006
VALVE, PRESSURE RELIEF,
210 BAR
1
5
99-153-015
VALVE SOLENOID,
STANDARD, w/o COIL
1
INSTALLATION INSTRUCTIONS
Review this entire section before installing the scissor lift table. Consult the factory in the event of questions or
problems at the time of installation.
Modifications or additions to the lift table, without prior authorization by the manufacturer, may void the warranty.
See ANSI standard MH29.1-2003,
Safety Requirements for Industrial Scissor Lifts
, Section 12.6. Attaching ancillary
equipment to the platform will lower its load capacity.
The installation shall comply with all applicable regulations for its location and use.
The end user is responsible for verifying that this lift table and its installation are suitable for its environment and
application.
This lift table shall be installed only by qualified and trained personnel with access to appropriate equipment.
Electrical connections shall be performed by a qualified electrician.
Before You Begin.
The Electric Hydraulic Scissors Lift Table must be anchored to a smooth, level, and adequately strong concrete
surface. See the INSTALLATION DIMENSIONS diagrams and table to plan your installation.
Before placing the lift table in a pit, determine the routing for the electric and hydraulic lines connecting the table
with its power unit. A cable and hose bundle, 7’-6” in length, connects the EHLTX table to the external power unit.
Contact the factory if different connections are needed.