background image

5.

OPERATING LIFT TABLE

How to use the brake. 

CAUTION 

Brake lift table when not moving it in order to prevent sudden movement. 

The brake is equipped with the swivel caster on the right side. 

(1)    Braking the wheel, press the brake pedal. 

(2)    Releasing the brake, lift up the brake pedal. 

6.

LIFTING UP FORKS

CAUTION 

1.

DO NOT overload lifter. Stay within its rated capacity.

2.

Prolonged continuous working might cause damage of hydraulic power pack.

3.

Step operation if temperature of hydraulic oil is too high.

Push the button “UP” and the table lift up. 

7.LOWERING TABLE 

CAUTION 

DO NOT lower table with load too fast and stop suddenly. Impact load could be created and lifter could be damaged. 

Push the button DOWN and the table lower. 

8.MOVING THE LIFTER 

WARNING 

DO NOT move lifter on slope or inclined surface, otherwise lifter become uncontrollable and create danger. 

(1)  Make the load stable to prevent it to fall. 

(2)  Lower the table down. 

(3)  Release the brake and move the lifter. 

(DOWN)

(UP)

Summary of Contents for CART-1000-DC

Page 1: ...ction Manual Instruction Manual Instruction Manual Instruction Manual ELECTRIC LIFT TABLE Model CART 1000 DC Note Owner Operator must read and understand this instruction manual before using the lift...

Page 2: ...AL INJURY or DEATH could result 5 DO NOT use in area of multilevel floor surface that could create loss control and result in SEVERE INJURY and PROPERTY DAMAGE 6 DO NOT use lifter on slope uneven or s...

Page 3: ...the load to fall SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result 7 DO NOT use lifter with unstable unbalanced or loosely stacked load Unbalanced loads may become unstable and fall SEVERE PERSO...

Page 4: ...4 NAME OF PARTS CART 1000 DC 1 Handle 4 Platform 2 Switch 5 Link 3 Brake Pedal 6 Guide rail...

Page 5: ...working might cause damage of hydraulic power pack 3 Step operation if temperature of hydraulic oil is too high Push the button UP and the table lift up 7 LOWERING TABLE CAUTION DO NOT lower table wit...

Page 6: ...UBLE CAUSE REPAIR 1 Faulty wiring 1 Check the wiring referring to the actual wiring diagram 2 Battery socket is disconnected 2 Connect the battery socket Platform do not rise while motor does not run...

Page 7: ...hydraulic power pack Approx numbers of lifting at full charge and with full load times 55 Approx time required to lift up table sec 15 Wheel in diameter 6 Handle height in 56 Weight lbs 326 13 HYDRAU...

Page 8: ...24 C 1000 DC 08 24 NUT HEX 1 25 C 1000 DC 08 25 PLATE 1 26 C 1000 DC 08 26 WASHER FLAT 10 27 C 1000 DC 08 27 WASHER LOCK 9 28 C 1000 DC 08 28 SCREW PHILLIPS HEAD MACHINE 1 29 C 1000 DC 08 29 NUT NYLO...

Page 9: ...RING RETAINING 6 81 C 1000 DC 08 81 ROLLER DECK 2 82 C 1000 DC 08 82 BUSHING 2 83 C 1000 DC 08 83 PIN COTTER 2 84 C 1000 DC 08 84 NUT NYLON LOCK M16 1 85 C 1000 DC 08 85 WASHER 1 86 C 1000 DC 08 86 B...