  Option: start with lower limit position setting 

 

– Hold down the button 

 to move the motor in the re-

quested 

lower

 limit position.

 

– Press the button 

 shortly.

 

– The red LED of button 

 starts blinking as long as the 

limit setting process is in progress.

 

– The red LED of button 

 lit solid if the process is  finished.

 

– Hold down the button 

 till motor stops automatically 

due to obstacle detection. Upper physical limit position 

is now set.

 

– The motor needs the following complete movements 

 (figure 3) to memorize the limit position. (Hold down the 
button 

 or 

  to move the motor in the requested

direc tion). The motor will give a feedback (short up / down 

movement) to confirm that the installation procedure has 
ended.

Physical – Virtual

  Advice:  start with upper limit position setting

 

– Hold down the button 

 till motor stops automatically 

due to obstacle detection. Upper physical limit position 

is now set.

 

– Hold down the button 

 to move the motor in the re-

quested 

lower

 limit position.

 

– Press the button 

 shortly.

 

– The red LED of button 

 starts blinking as long as the 

limit setting process is in progress.

 

– The red LED of button 

 lit solid if the process is  finished.

 

– The motor needs the following complete movements 

 (figure 2) to memorize the limit position. (Hold down the 
button 

  or 

  to move the motor in the requested

direc tion). The motor will give a feedback (short up / down 

movement) to confirm that the installation procedure has 
ended.

UP

DOWN

red

Change 

turning 

direction

green

yellow

Fig. 2

Fig. 3

  Option: start with lower limit position setting 

 

– Hold down the button 

  till motor stops automatically 

due to obstacle detection. Lower physical limit position is 

now set. 

 

– Hold down the button 

 till motor stops auto matically 

due to obstacle detection. Upper physical limit position 

is now set.

 

– The motor needs the following complete movements

( figure 7) to memorize the limit posi tion. (Hold down the
button 

 or 

  to move the motor in the requested 

direc tion). The motor will give a feedback (short up / down 

movement) to confirm that the installation procedure has 
ended.

Physical – Physical

  Advice:  start with upper limit position setting

 

– Hold down the button 

 till motor stops auto matically 

due to obstacle detection. Upper physical limit position 

is now set.

 

– Hold down the button 

  till motor stops automatically 

due to obstacle detection. Lower physical limit position is 

now set.

 

– The motor needs the following complete movements 

( figure 6) to memorize the limit posi tion. (Hold down the
button 

 or 

  to move the motor in the requested 

direc tion). The motor will give a feedback (short up / down 

movement) to confirm that the installation procedure has 

ended.

UP

DOWN

red

Change 

turning 

direction

green

yellow

Fig. 6

Fig. 7

  Advice:  start with upper limit position setting

 

– Hold down the button 

 to move the motor in the re-

quested 

upper

 limit position.

 

– Press the button 

 shortly.

 

– The 

green

 LED of button 

 starts blinking as long as 

the limit setting process is in progress.

 

– The 

green

 LED of button 

 lit solid if the process is 

 finished.

 

– Hold down the button 

  till motor stops automatically 

due to obstacle detection. Lower physical limit position is 

now set.

 

– The motor needs the following complete movements 

 (figure 4) to memorize the limit position. (Hold down the 
button 

  or 

  to move the motor in the requested

direc tion). The motor will give a feedback (short up / down 

movement) to confirm that the installation procedure has 

ended.

Virtual – Physical

  Option: start with lower limit position setting 

 

– Hold down the button 

  till motor stops automatically 

due to obstacle detection. Lower physical limit position is 

now set. 

 

– Hold down the button 

 to move the motor in the re-

quested 

upper

 limit position.

 

– Press the button 

 shortly.

 

– The 

green

 LED of button 

 starts blinking as long as 

the limit setting process is in progress.

 

– The 

green

 LED of button 

 lit solid if the process is 

 finished.

 

– The motor needs the following complete movement 

 (figure 5) to memorize the limit position. (Hold down the
button 

 to move the motor in the requested direction).

The motor will give a feedback (short up / down movement) 

to confirm that the installation procedure has ended.

UP

DOWN

red

Change 

turning 

direction

green

yellow

Fig. 5

Fig. 4

Summary of Contents for VL-ME-230-45 Series

Page 1: ...y network e g if maintenance work has to be done close to them CONTENTS 1 Safety precautions safety measures 2 Short description identification of products 3 Scope of delivery 4 Intended use 5 Technic...

Page 2: ...m connection cable Operating instructions Adapter set comprising tube adapter adapter ring Mounting kit comprising safety clip safety cotter 5 Technical data Article VL ME 230 45 10Nm 20Nm 30Nm 50Nm A...

Page 3: ...e 1 Move the roller shutter or screen completely down before disconnecting the tube connectors Dissasembly of tubular shaft Place the mounting bracket to the desired position Assembly of the motor can...

Page 4: ...ED yellow LED Intermediate position yellow Button Set Intermediate position Hint Intermediate position Not used for these motor devices OFF when no Intermediate position is set Blinking when programmi...

Page 5: ...nd lower limit position are physical UP DOWN red Change turning direction green yellow Virtual Virtual Option start with lower limit position setting Hold down the button to move the motor in the re q...

Page 6: ...motor in the requested direction The motor will give a feedback short up down movement to confirm that the installation procedure has ended Physical Physical Advice start with upper limit position se...

Page 7: ...downwards 1 Preset endpoint reached 1 Set the end limits again according to the instructions 2 Cutoff by internal temperature fuse 2 Allow the motor to cool down for 20 min Motor stops while moving up...

Reviews: