Description of installation tool VL-Progset-ME/SMI-230

UP + green LED – Virtual upper limit set  

yellow LED – Intermediate position  

DOWN + red LED – Virtual lower limit set  

green LED – Power  

red LED – Change turning direction  

Virtual upper limit  

Intermediate position  

Virtual lower limit  

Reset  

Change turning direction  

Left side: Motor control

Right side: Motor programming

Motor control

Motor programming

Button

Control motor in 

UP

 direction

Hold down the button to move the motor in

UP

 direction.

green

Button

Set “Virtual upper limit position”.

LED

green LED

 – Virtual upper limit position:

OFF

when no “Virtual upper limit” is set.

Blinking

when programming “Virtual upper limit”

or “RESET” is in progress.

Lit solid

when “Virtual upper limit” programming 

sequence has completed.

LED

yellow LED

 – Intermediate position:

yellow

Button

Set “Intermediate position”.

Hint:

 

Intermediate position:

Not used for these

motor   devices.

OFF

when no “Intermediate position” is set.

Blinking

when programming “Intermediate

position” is in progress.

Lit solid

when “Intermediate position” pro gramming 

sequence has been completed.

Button

Control motor in 

DOWN

 direction

Hold down the button to move the motor in

DOWN

 direction.

red

Button

Set “Virtual lower limit position”.

LED

red LED

 – Virtual lower limit position:

OFF

when no “Virtual lower limit” is set.

Blinking

when programming “Virtual lower limit”

or “RESET” is in progress.

Lit solid

when “Virtual lower limit” programming 

sequence has completed.

LED

green LED 

– Power:

OFF

when powerless (it is safe to connect 

a motor to the Installation Tool).

green

Button

Reset

Lit solid

when attached to mains 230VAC.

LED

red LED

 – Change turning direction:

OFF

when no “Change turning direction” 

is used.

red

Button

Change motor turning direction.

Blinking

when “Change motor turning direction” 

programming  sequence is in progress.

Lit solid

when “Change motor turning direction” 

programming  sequence has completed.

Summary of Contents for VL-ME-230-45 Series

Page 1: ...y network e g if maintenance work has to be done close to them CONTENTS 1 Safety precautions safety measures 2 Short description identification of products 3 Scope of delivery 4 Intended use 5 Technic...

Page 2: ...m connection cable Operating instructions Adapter set comprising tube adapter adapter ring Mounting kit comprising safety clip safety cotter 5 Technical data Article VL ME 230 45 10Nm 20Nm 30Nm 50Nm A...

Page 3: ...e 1 Move the roller shutter or screen completely down before disconnecting the tube connectors Dissasembly of tubular shaft Place the mounting bracket to the desired position Assembly of the motor can...

Page 4: ...ED yellow LED Intermediate position yellow Button Set Intermediate position Hint Intermediate position Not used for these motor devices OFF when no Intermediate position is set Blinking when programmi...

Page 5: ...nd lower limit position are physical UP DOWN red Change turning direction green yellow Virtual Virtual Option start with lower limit position setting Hold down the button to move the motor in the re q...

Page 6: ...motor in the requested direction The motor will give a feedback short up down movement to confirm that the installation procedure has ended Physical Physical Advice start with upper limit position se...

Page 7: ...downwards 1 Preset endpoint reached 1 Set the end limits again according to the instructions 2 Cutoff by internal temperature fuse 2 Allow the motor to cool down for 20 min Motor stops while moving up...