Note Basic functions
The
Vestamatic
Rollmat Plus V3.1
roller shutter control is deliv-
ered with the following manufacturer’s default up and down times
(day function is activated):
·
Daily up time –
0ß6:0ß0
every morning
·
Daily down time –
2ß0:0ß0
every evening
Please find the manufacturer’s default DIP switch settings
in the tables on page 50 and page 53.
Important: It is important to push the selector switch “auto-
matic/manual mode” to automatic mode (A), in order
to be able to perform the following programming
steps.
Check the current setting. If the selector switch is
not set on (A), correct the setting by pushing it all
the way to the left until you hear the “click”.
- 41 -
G
Basic functions Up time
By operating the combination of set and up button you can set
the up time.
Setting the up time can be performed as follows:
1. Press the set button first and keep it pressed, then:
A. Press the up button and keep it pressed to
fast forward
the up time.
B. Shortly tap the up button to
slow forward
the up time.
or
2. Press the up button first and keep it pressed, then:
A. Press the set button and keep it pressed to
fast reverse
the up time.
B. Shortly tap the set button to
slow reverse
the up time.
The display will now indicate the set value. Once the programming
buttons are no longer operated, the display will indicate the cur-
rent time again. Tapping the up button will check the set value
and the display will again indicate the previously set up time.
After approx. 2 seconds, the display will indicate the current time
again.
- 42 -
G