8. Troubleshooting
Problem
Possible cause
Solution
Motor is not responding.
1. No mains voltage.
1. Check mains voltage.
2. Connection error.
2. Check connections (see wiring diagram).
3. Cutoff by internal temperature fuse.
3. Allow the motor to cool down for 20 min.
Motor starts slowly or makes too
much noise.
1. Connection error.
1. Check connections.
2. Installation error or undersized motor selected.
2. Check installation and motor load.
Motor rotation direction is wrong.
Motor connection cables are reversed.
Disconnect the supply line from the power, and swap
the black and brown conductors of the motor cable at
the controller.
Motor stops while moving up or
downwards.
1. Preset endpoint reached.
1. Set the end limits again, according to the instructions.
2. Cutoff by internal temperature fuse.
2. Allow the motor to cool down for 20 min.
Motor stops while moving upwards.
Iced roller shutter or obstacle in running rail.
Remove icing or obstacle. Release the roller shutter by
steering the motor in downward direction.
The motor is maintenance-free.
10. Maintenance
The disposal of electrical equipment and batteries in household
waste is strictly forbidden.
The symbol (dustbin crossed out, in line with WEEE Appendix IV)
indicates separate collection of electrical and electronic products in
EU countries. Do not dispose of the device or battery in your house-
hold waste. Ask your town or local council about the return and col-
lection systems available in your area to dispose of this product.
É
11. Disposal of waste
9. Warranty
Principally, the General Terms and Conditions of the manufacturer, Ves-
tamatic GmbH apply. The terms and conditions are part of the sales doc-
uments and handed over to the operator upon delivery. Liability claims for
personal or material damages are excluded when they can be at tri buted to
one or more of the following causes:
– Unintended use of the product.
– Opening of the product by the customer.
– Improper installation, commissioning, or operation of the product.
– Non-compliance with the specifications.
– Non-observance of the safety provisions and instructions of the Oper-
ating Instructions.
– Operation of the product with improperly installed connections, defec-
tive safety devices or improperly installed safeguards.
– Modifications to the product.
12. Support / Contact
Vestamatic GmbH
Dohrweg 27
41066 Mönchengladbach
Germany
Phone: +49 2161 / 29 408-0