background image

Subject to modifications.

© Vestamatic GmbH

Art.-Nr.: 

8900 001 GB 3117 A04  •  Vestamatic GmbH  •  Dohrweg 27  •  D-41066 Mönchengladbach 

 •  www.vestamatic.com

10/10

G

H O M E   VL-SMI-230-45

8. Troubleshooting

Problem

Possible cause

Solution

 

„

Motor is not responding.

1.  No mains voltage.

1.  Check mains voltage.

2.  Connection error.

2.  Check connections (see wiring diagram).

3.  Cutoff by internal temperature fuse.

3.  Allow the motor to cool down for 20 min.

 

„

Motor starts slowly or makes too 

much noise.

1.  Connection error.

1.  Check connections.

2.  Installation error or undersized motor selected.

2.  Check installation and motor load.

 

„

Motor rotation direction is wrong.

Motor connection cables are reversed.

Disconnect the supply line from the power, and swap 

the black and brown conductors of the motor cable at 

the controller.

 

„

Motor stops while moving up or 

downwards.

1.  Preset endpoint reached.

1.  Set the end limits again, according to the instructions.

2.  Cutoff by internal temperature fuse.

2.  Allow the motor to cool down for 20 min.

 

„

Motor stops while moving upwards.

Iced roller shutter or obstacle in running rail.

Remove icing or obstacle. Release the roller shutter by 

steering the motor in downward direction.

The motor is maintenance-free.

10. Maintenance

The disposal of electrical equipment and batteries in household 

waste is strictly forbidden.

The symbol (dustbin crossed out, in line with WEEE Appendix IV) 

indicates separate collection of electrical and electronic products in 

EU countries. Do not dispose of the device or battery in your house-

hold waste. Ask your town or local council about the return and col-

lection systems available in your area to dispose of this product.

É

11. Disposal of waste

9. Warranty

Principally, the General Terms and Conditions of the manufacturer, Ves-

tamatic GmbH apply. The terms and conditions are part of the sales doc-

uments and handed over to the operator upon delivery. Liability claims for 

personal or material damages are excluded when they can be at tri buted to 

one or more of the following causes:

 

– Unintended use of the product.

 

– Opening of the product by the customer.

 

– Improper installation, commissioning, or operation of the product.

 

– Non-compliance with the specifications.

 

– Non-observance of the safety provisions and instructions of the Oper-

ating Instructions.

 

– Operation of the product with improperly installed connections, defec-

tive safety devices or improperly installed safeguards.

 

– Modifications to the product.

12.  Support / Contact

Vestamatic GmbH

Dohrweg 27

41066 Mönchengladbach 

Germany

[email protected]

Phone: +49 2161 / 29 408-0

Summary of Contents for 01066291

Page 1: ...ted shades protect them against unauthorised or uninten tional operation CONTENTS 1 Safety precautions safety measures 2 Short description identification of products 3 Scope of delivery 4 Intended use...

Page 2: ...The change over time for changing the running direction up down must be least 0 5 sec ATTENTION Follow the safety instructions according to EN 60335 2 97 Additional components for the implemen tation...

Page 3: ...e from communication mode to switch mode a one time sequen tially up and down button press is necessary Note on laying SMI wires in custom cables The I and I SMI wires can be laid in the motor connect...

Page 4: ...01 GB 3117 A04 Vestamatic GmbH Dohrweg 27 D 41066 M nchengladbach www vestamatic com SMI drives on different AC phases ATTENTION Parallel connection to the control lines I and I while supplying pow er...

Page 5: ...gure 1 Move the sunshade or screen completely down before disconnecting the tube connectors Dissasembly of tubular shaft Place the mounting bracket to the desired position Assembly of the motor can be...

Page 6: ...amming sequence has completed LED yellow LED Intermediate position yellow Button Set Intermediate position OFF when no Intermediate position is set Blinking when Intermediate position programming is i...

Page 7: ...d lower limit position are physical UP DOWN red Change turning direction green yellow Virtual Virtual Option start with lower limit position setting Hold down the button to move the motor in the re qu...

Page 8: ...ection The motor will give a feedback short up down movement to confirm that the installation procedure has ended UP DOWN red Change turning direction green yellow figure 2 figure 3 Advice start with...

Page 9: ...w LED lit solid if the process is finished The motor will give a feedback short DOWN UP movement to confirm that the installation procedure has ended When an intermediate position is pro grammed the m...

Page 10: ...on The motor is maintenance free 10 Maintenance The disposal of electrical equipment and batteries in household waste is strictly forbidden The symbol dustbin crossed out in line with WEEE Appendix IV...