Maximum Operation Load
110V: 6600W and 60A
230V: 13800W and 60A.
Z-Wave Information
Device Type:
Whole Home Meter - Simple
Role Type:
Always On Slave (AOS)
Command Class Support/Control
Mandatory CC Support: Association CC, v2
Association Group Information CC
Device Reset Locally CC
Manufacturer Specific CC, v2
Multi Channel Association CC, V3
Multi Channel CC, V4
Meter CC, V2
CRC 16 ENCAP
Version CC, v2
Z-Wave Plus Info CC, v2
Power Level CC,
Firmware Update CC, v2
Z-Wave’s Groups (Association Command Class Version 2)
The meter can be set to send reports to associated Z-Wave devices. It supports 3 association groups which every
group has one node support. Group 1~Group 3 support METER_REPORT_COMMAND_V2
Group 1 for “LifeLine”: (maximum node:1)
Device Reset Locally CC, V2
Meter CC, V2
For group 1, the Clamp Meter will report:
(1) The sum of instant Power Consumption (Watt) read from CT1 and CT2
(2) The sum of accumulated Power Consumption (KWh) read from CT1 and CT2
Group 2 for “meter CT1” (maximum node: 1)
Meter CC, V2
For group 2, the Switch will report:
(1) Instant Power Consumption (Watt) read from CT1
(2) Accumulated Power Consumption (KWh) read from CT1
Group 3 for “meter CT2”: (maximum node: 1)
Meter CC, V2
For group 3, the Switch will report
(1) The sum of instant Power Consumption (Watt) read from CT2
(2) The sum of accumulated Power Consumption (KWh) read from CT2
Z-Wave’s
Multi Channel Association
The Multi Channel Association Command Class is used to create application bindings to Multi Channel End Point
resources as well as to Root Devices. The command class can handle nodes with and without end points.
For Root, it supports maximum 1 node and maximum 3 association groups
Root
Profile 2 bytes
Command Class
Group Name
(UTF-8)
Group 1
General: lifeline
Device reset locally and
meter report
“Lifeline”
Group 2
Meter: Electric Meter
meter report
“Meter CT 1”
(mirror of endpoint 1 group2)
Group 3
Meter: Electric Meter
meter report
“Meter CT 2”
(mirror of endpoint 2 group2)
For Endpoint 1, it supports maximum 1 node and maximum 2 association groups.
Endpoint 1
Profile 2 bytes
Command Class
Group Name
(UTF-8)
Group 1
General: lifeline
meter report
“Lifeline EP 1”
Group 2
Meter: Electric Meter
meter report
“Meter CT 1”
For Endpoint 2, it supports maximum 1 node and maximum 2 association groups.
Endpoint 2
Profile 2 bytes
Command Class
Group Name
(UTF-8)
Group 1
General: lifeline
meter report
“Lifeline EP 2”
Group 2
Meter: Electric Meter
meter report
“Meter CT 2”