Clamp Meter (CLMT-1ZW) 

CL-Meter-ZW  is a Z-Wave  Clamp Meter aim to monitor and report the total amount of electricity uses in your 
facility by connecting the clamp onto the power cable. 

The Energy Meter is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. 

Z-Wave is a wireless communication protocol  that  uses a low-power  RF radio.  By taking advantage of the 
Z-Wave mesh network, commands can be routed to their destination via intermediary  “listening”  Z-Wave 
products. 
 

 

Parts Identification 

1.  Red LED 

Flashes once: 

When Clamp Meter is transmitting a signal. 

Flash Twice: 

The Clamp Meter has successfully joined a Z-Wave network. 

2.  AC Input cable 

3.  Current Transformer Cable (CT2) 

4.  Current Transformer Cable (CT1) 

5.  Function Button 

-Press the button once to report the value of the meter to the Z-Wave network. 

-Press the button 3 times within 1.5 seconds to transmit a learn code. 

-Press and hold the button for 10 seconds to factory reset the Clamp Meter. 

6.  Reserved 

7.  Mounting Hole 

8.  Mounting Hooks 

9.  Mounting Bracket   

 

 

 

 

 

 

Summary of Contents for CLMT-1ZW

Page 1: ...can be routed to their destination via intermediary listening Z Wave products Parts Identification 1 Red LED Flashes once When Clamp Meter is transmitting a signal Flash Twice The Clamp Meter has successfully joined a Z Wave network 2 AC Input cable 3 Current Transformer Cable CT2 4 Current Transformer Cable CT1 5 Function Button Press the button once to report the value of the meter to the Z Wave...

Page 2: ...t at the correct direction of the electricity current flows K L If arrow is faced in reverse direction the reading will display negative value however it will not influence the readings 3 Follow the schematics below as an example clip the clamps on the electricity cables on the 2 the incoming power cable connected to the Main Circuit Breaker Mounting The Clamp Meter has a mounting bracket for moun...

Page 3: ...e if the Z Wave Gateway or Control Panel is lost or otherwise inoperable Press and hold the Function Button of the device for 10 seconds to factory reset Range Test To test whether the device is able to communicate with the Z Wave Gateway or Control Panel Put the Gateway Control Panel into range test mode Walk Test Press the Function Button on the device The Gateway Control Panel should display if...

Page 4: ...tion KWh read from CT1 Group 3 for meter CT2 maximum node 1 Meter CC V2 For group 3 the Switch will report 1 The sum of instant Power Consumption Watt read from CT2 2 The sum of accumulated Power Consumption KWh read from CT2 Z Wave s Multi Channel Association The Multi Channel Association Command Class is used to create application bindings to Multi Channel End Point resources as well as to Root ...

Page 5: ... Channel Association CC V3 Meter CC V2 Descirption For Endpoint 1 the Clamp Meter will report 1 Instant Power Consumption Watt read from CT1 2 Accumulated Power Consumption KWh read from CT1 Selected Endpoint 2 for CT2 of the second channel Device Type Simple Meter Supported Command Classes Z Wave Plus info CC V2 Association CC V2 Association Group Information CC Multi Channel Association CC V3 Me...

Reviews: