8
Before Use
CAUTIONS
BEFORE USE
REMEMBER
Use only the included power supply adapter. Use of other adapters may
results in fire, electric shock and static electricity removal trouble.
REMEMBER
If noticing anything strange, stop using the F120S-E immediately.
PROHIBITED
Do not use the F120S-E for other purpose than static electricity removal.
PROHIBITED
Do not remodel or disassemble the F120S-E. The F120S-E contains high
voltage parts.
PROHIBITED
Do not drop the F120S-E or apply strong impacts.
PROHIBITED
Keep the F120S-E away from sources of heat.
PROHIBITED
Do not test the electrode needles for grounding, short-circuiting or
sparking. These tests can adversely affect ion balance.
Connector connection
Insert the included dedicated AC adapter connector into the jack
on the back of the body.
Power Supply Adapter
Use the power adapter (AD24-IT) which is specifically designed for use of the F120S-E.
The AC adapter plug is a 3-pronged plug.
Connect this to a power outlet that has a ground terminal.
When an external power supply is used
Use the wire of AWG28-22.
Strip 9 to 10mm in length of the sheath.
Connect DC24V to terminal #1 and the
ground to the terminal #2.
Note the polarity of the power supply.
Use a stable power supply with no noise.
Ground through the external grounding terminal or the terminal #2.
Wiring in a daisy chain
On the circuit, terminal #1 and #9 are connected in parallel (DC24V), terminal #2 and #10 are also
connected in parallel (ground). Since power is distributed, you can connect up to two units of this product.
* A switching power with electric capacity of 1.5 A or more is required.
* The included AC adapter (AD24-IT) can not be used for daisy chain wiring.