background image

15 

„

 

Troubleshooting 

Using the F120S-E in anything but proper working condition can cause damages on the product or 
accidents/injuries on the personnel. 
Therefore, promptly request servicing if trouble occurs. For servicing, contact us or our distributors. 

 CAUTION 

 

TROUBLESHOOTING

 

 

 

PROHIBITED

 

Do not use the F120S-E in the following situations. It may result in fire or 
electric shock. 
* When the F120S-E has been damaged because of dropping or shock 
* When air is not blowing though the power switch of the eraser is in the 

ON position 

* When the power cable is damaged or hot 
* When the power supply adapter is loosely connected to the electrical outlet. 
* When the F120S-E is damaged because of dropping, shock or other 

causes. 

 

 

UNPLUG 
POWER CABLE 

If trouble occurs with the F120S-E, turn the power switch OFF and unplug 
the power cable.

 

   

DO NOT 
DISASSEMBLE

 

Do not disassemble the F120S-E. 

 

„

 

Storage

 

In the following cases, contact the supplier for servicing. 
Do not service the F120S-E by yourself to avoid accidents. 

* The power lamp does not light when the power switch is in the ON position 
* Air is not blown when the airflow switch is turned 
* When the F120S-E is moved during operation, sometimes airflow comes out or sometimes not 
* The power cable is excessively hot 
* The power supply adapter is excessively hot 
* If the F120S-E emits strange noises or vibrates during operation 
* If sparks are seen coming from electrode needle tips (In normal operation, sparks are not seen.) 

 CAUTION

     

STORAGE

 

 

PROHIBITED

 

Do not store the F120S-E in the following places. 
Adverse environments can cause product breakdown. 
* Where exposed to vibrations or shock 
* Where temperature and humidity are exceed specified ranges 
* Where dewing occurs 
* Where temperature fluctuates sharply 
* Where there is the possibility of ignition or explosion of flammable 
solvents, dust, etc. 
* Where there is heavy dust, particles or smoke 
* Where possibly wet by water, oil, chemicals, etc. 
* Where strong electric or magnetic fields are generated

 

 

Summary of Contents for Stat Clean F120S-E

Page 1: ...ion manual before use Keep it in a safe handy place for future reference Table of Contents For Your Safety P 2 Product Features P 3 Production Specifications P 4 External View P 5 Performance P 6 Installation P 7 Before Use P 8 Operation P 9 Maintenance P 12 Troubleshooting P 16 Storage P 17 Warranty P 18 ...

Page 2: ... act as an ignition source and cause an explosion or fire PROHIBITED Do not use the F120S E in environments subjected to sharp temperature fluctuations or dewing This kind of environment can lead to breakdown DO NOT WET Do not use the F120S E in highly damp places or anywhere it may be wet by water oil solvent or other liquid Contact with moisture can result in electric shock or breakdown PROHIBIT...

Page 3: ...ont cover can be changed to straight or wide to set the static erasing range Safe design When the front cover is removed the circuit is shut off and the power is turned OFF to prevent electric shocks Fan lock alarm function and high voltage output stop alarm function are available as a standard The status is indicated with LED lamps The alarm signals can be output externally to operate an external...

Page 4: ...idity 5 40 35 65 RH No dewing Storage temperature humidity 0 60 35 85 RH No dewing Distance from target area 150 900mm Installation location Non hazardrous indoor location Static electricity removal time Refer to the items in the capabilities chart Ion balance Within 10V max and straight airflow without filter at the time of shipment from the manufacture s warehouse Material Casing Flame retardant...

Page 5: ...5 External View No F120S E No AD 24 IT EX ...

Page 6: ...y Removal Performance Based on ANSI EOS ESD S3 1 compliant CPM TREK 158 Temperature 25 Humidity 50 The above values were based on tests with a sample unit They represent the central tendency of this model but they are not guaranteed ...

Page 7: ...e generated When Used on a Desktop The F120S E can be used on the desktop Do not locate on unstable tables etc the F120S E can be damaged and or malfunction if it is dropped When Mounted on a Wall or a Structure Select a location and height in consideration of F120S E s static electricity removal range For information regarding the static electricity removal range refer to Static Electricity Remov...

Page 8: ... AC adapter connector into the jack on the back of the body Power Supply Adapter Use the power adapter AD24 IT which is specifically designed for use of the F120S E The AC adapter plug is a 3 pronged plug Connect this to a power outlet that has a ground terminal When an external power supply is used Use the wire of AWG28 22 Strip 9 to 10mm in length of the sheath Connect DC24V to terminal 1 and th...

Page 9: ... up in green and then the unit start the operation When you press the power switch again power is turned off Fan speed The fan s airflow volume can be adjusted in three steps LO MD HI Please adjust the air with the Airflow switch Variable louver The airflow direction angle at the front cover can be changed to set the static erasing range Straight Wide angle This is useful when the charged object i...

Page 10: ...ed to the fan remove them switch on the power again and make sure that the lamp is off If the alarm lamp light in red again even though the causes are resolved contact the supplier for servicing to avoid accidents Immediately after turning on the power there is a moment that the fan lamp glows red This is not a malfunction When externally outputting the alarm signal The lights and other external a...

Page 11: ...l contact External contact GND DC24V OUT GND Photo coupler SHARP PC817 Filter Option Fan filter is available depending on the applications 1 Loosen with a Philips screwdriver the screws 4 pcs which fix the fan on the backside 2 Replace metal Finger Guard with a resin Finger Guard of Filter set and fix the resin Finger Guard with screws 3 Mount filter with a filter cover ...

Page 12: ...s such as alcohol or paint thinner It may cause cracking and result in electric shock or breakdown DO NOT WET Do not wet the F120S E Contact with moisture can result in electric shock or breakdown When cleaning the front cover After using for long hours dust adhered to the front cover may lower the ionizing performance or cause dust to fly around Care for periodical cleaning 1 Be sure to turn the ...

Page 13: ...edure set forth in the preceding paragraph 4 Attach the front cover to the F120S E and connect the AC adapter Make sure the front cover is securely installed If the cover is not installed correctly the safety mechanism will operate causing the fan to stop CAUTION CLEANING If the discharge needle is dirty it could lower the static erasing performance or cause dust to fly around Be sure to clean the...

Page 14: ...damage the F120S E 5 Wipe off the dust adhered on the filter cover with a cloth Dust may also be on the outside and or inside the filter cover so use a dry and soft cloth to wipe dust off 6 Mount again the filter and the filter cover CAUTION CLEANING If the filter is dirty it could lower the static erasing performance or cause dust to fly around Be sure to clean the contaminated parts according to...

Page 15: ...n the following cases contact the supplier for servicing Do not service the F120S E by yourself to avoid accidents The power lamp does not light when the power switch is in the ON position Air is not blown when the airflow switch is turned When the F120S E is moved during operation sometimes airflow comes out or sometimes not The power cable is excessively hot The power supply adapter is excessive...

Page 16: ...glect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tort or contract...