CAUTIONS   

IN INSTALLATION

 

 

REMEMBER 

Use only the included power supply adapter. Use of other adapters may 
results in fire, electric shock and static electricity removal trouble. 

 

REMEMBER 

Install F-6R securely. F-6R can be damaged or malfunctioned if it falls. 

 

REMEMBER 

Install F-6R based on below stated environment. 
Adverse environments cause product deterioration and breakdown. 

Humidity: 35~65%RH (No dewing or freezing)    Temperature: 5~40

 

 

PROHIBITED 

Do not use F-6R based on below stated environments. 
Adverse  environments  can  result  in  explosion,  fire,  electric  shock  and 
accident.

 

*Where explosion-proofing is required. 
*Where flammable atmospheres found. 
*Where temperature and humidity are outside specified ranges. 
*Where dewing or sharp temperature fluctuations occurs. 
*Where there is heavy dust or smoke. 
*Where possibly wet by water, oil, chemicals, etc. 
*Where strong electric or magnetic fields are generated. 

1. To be installed on desktop (F-6RST-E) 

Do not place the unit on an unstable surface. It may cause breakage if the unit falls. 

2. To be mounted to walls or structures (F-6RST-E) 

The installation height should be determined with its effective 
ionizing area in mind. 
The unit can be mounted onto structures / cell-production 
benches by the 5 screw holes (φ6.5mm) on the bottom. 
Also, the unit angle becomes adjustable by loosening the Trass 
screws on its sides. Fasten the screws securely after 
adjustment.   
Make sure there is no obstacle between the unit and the work 
material.   
Make sure the strength of the structure to which the unit is 
mounted. 
When installing the unit, make sure not to block the air intake 
area. 
At least 10cm distance shall be kept between the air intake 
area and the wall. 

 

 

 

5-

Φ

6.5

Trass screw (M5)

Rubber washer

60

Summary of Contents for F-6R

Page 1: ...al before use Keep it in a safe handy place for future reference Table of Contents For Your Safety P 2 Product Features P 3 Production Specifications P 4 External View P 5 Performance P 6 Installation P 6 Before Use P 8 Operation P 9 Maintenance P 10 Troubleshooting P 14 Storage P 15 Warranty P 16 ...

Page 2: ...explosion proofing F 6R is not of explosion proof construction therefore explosion or fire may occur PROHIBITED Do not use F 6R in flammable atmospheres The corona discharge can act as an ignition source and cause an explosion or fire PROHIBITED Do not use F 6R in environments subjected to sharp temperature fluctuations or dewing This kind of environment can lead to breakdown DO NOT WET Do not use...

Page 3: ... machinery DESIGNED FOR SAFETY To prevent electrical shock the circuit is cut off and the power turned off when the front guard is opened During operation the interior high brightness white LED lights up and the operating condition can be visually checked LED Lamp Function The red LED indicators on the top of the unit notify you in case of fan motor stoppage and abnormally high voltage High voltag...

Page 4: ...ltage output shut down function overload detection Front cover safety device circuit cut off when open Protective function Over current protection fuse 1 0 A Reverse current connector protection diode 60 V 1 A Working temperature humidity 5 40 35 65 RH No dewing or freezing Storage temperature humidity 0 60 35 85 RH No dewing or freezing Distance from target area 150 600 mm Installation location N...

Page 5: ...21 External View External View AD24 ITF6 ...

Page 6: ... 6 8 4 9 9 9 4 4 4 5 4 5 5 5 6 8 3 7 4 6 5 1 7 4 5 2 6 4 5 5 5 6 7 9 100mm 9 8 2 4 1 6 8 5 2 6 2 6 8 9 2 9 3 1 1 8 3 0 3 6 6 2 4 0 4 9 4 1 4 3 5 7 50mm 3 5 3 0 1 5 0 9 2 5 2 1 6 3 2 6 2 7 4 0 3 1 3 5 5 9 3 5 4 1 3 5 4 2 4 9 0mm 9 8 2 1 3 5 0 2 4 2 6 0 4 3 0 3 3 0 3 3 2 3 7 1 9 3 8 4 4 4 5 4 2 5 4 50mm 8 5 4 0 3 0 3 8 4 2 4 4 4 6 4 5 5 1 4 7 4 7 5 2 1 2 4 8 5 5 0 7 4 7 6 1 100mm 0 5 55 5 44 8 2 2 1...

Page 7: ...ons occurs Where there is heavy dust or smoke Where possibly wet by water oil chemicals etc Where strong electric or magnetic fields are generated 1 To be installed on desktop F 6RST E Do not place the unit on an unstable surface It may cause breakage if the unit falls 2 To be mounted to walls or structures F 6RST E The installation height should be determined with its effective ionizing area in m...

Page 8: ...ans The length of M5 screws should be up to 6 mm from the surface of the unit Before Use CAUTIONS IN BEFORE USE REMEMBER Use only the included power supply adapter Use of other adapters may results in fire electric shock and static electricity removal trouble REMEMBER If noticing anything strange stop using F 6R immediately PROHIBITED Do not use F 6R other than static electricity removal PROHIBITE...

Page 9: ...me the power is turned on Low power consumption FAN SPEED Fan speed can be changed by two steps HI LO ALARM LAMPS H V ALARM High voltage alarm lamp High voltage alarm lamp lights when electrode needle is grounded short circuited or high voltage booster unit does not output enough voltage If any foreign object attached to the electrode needles Please refer to the How to Clean the Electrode needle o...

Page 10: ... electrode needle may sometimes require cleaning Dirt and wear in the electrode needle area can cause a decline static erasing capacity It is also recommended to measure ion balance and ion output as a means for checking for a drop in capacity Casing Cleaning To clean the casing wipe with a dry soft cloth Suck up dust from openings with a vacuum cleaner Do not use detergent or solvents such as alc...

Page 11: ...needle unit is broken or dropped out stop the operation and replace it with a new one It can lead to an electric shock or injury Instructions for cleaning 1 Pull off the plug of the AC DC power transformer from the power socket or pull off the connector of the transformer from the unit 2 Remove the stopper from the unit by pressing the sides of the stopper 3 Rotate the needle unit counter clockwis...

Page 12: ...28 27 ...

Page 13: ...R has been damaged because of dropping or shock When air is not blowing though the power switch of the eraser is in the ON position When the power cable is damaged or hot When the power supply adapter is loosely connected to the electrical outlet UNPLUG POWER CABLE If trouble occurs with F 6R turn the power switch OFF and unplug the power cable DO NOT DISASSEMBLE Do not disassemble F 6R In the fol...

Page 14: ...ions or shock Where temperature and humidity are outside specified ranges Where dewing occurs Where temperature fluctuates sharply Where there is the possibility of ignition or explosion of flammable solvents dust etc Where there is heavy dust or smoke Where possibly wet by water oil chemicals etc Where strong electric or magnetic fields are generated ...

Page 15: ...31 Memo ...

Page 16: ...t misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tort or contract ari...

Reviews: