Installation and maintenance instructions

DX100

Standard

DX100 PC

Pull Cord

DX100T

Time

r

DX100H

Humidistat

DX100HP

Humidistat and Pull Cord

DX100PIR

Integral Body Movement Sensor

DX100VTD

Delay Timer

Toilet/Bathroom 100mm/4" Fan Range

Retain for future reference

®

GB

F

D

NL

I

S

GR

N

SE

A

Summary of Contents for 100MM/4" RANGE DX100

Page 1: ... DX100 Standard DX100PC Pull Cord DX100T Timer DX100H Humidistat DX100HP Humidistat and Pull Cord DX100PIR Integral Body Movement Sensor DX100VTD Delay Timer Toilet Bathroom 100mm 4 Fan Range Retain for future reference GB F D NL I S GR N SE A ...

Page 2: ...2 A B D E F G C DX100PIR 1 2 5 m m 1 1 5 m m ...

Page 3: ...H 3 I J K DX100T DX100PIR DX100H DX100HP L ...

Page 4: ...2 5 minutes 27 After this time the fan will operate When the fan is switched off it will continue to operate for approximately 7 5 minutes 27 What the installer will need A double pole isolating switch with a minimum contact gap of 3mm wall or ceiling mounted If metal switch boxes are used earthing regulations must be followed Suitably rated 2 core cable DX100 DX100PC DX100HP and DX100PIR Suitably...

Page 5: ...le complete with 3 pin plug for insertion into an approved 10 amp GPO or directly wired through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts For Australia only DX100T DX100H DX100VTD These models are permanently connected to the supply and operation is controlled by a remote switch They should be directly wired to the supply through an approved 10amp wal...

Page 6: ...ip supplied and attach it around the outside of the lip on the back draught shutter 2 Go outside Holding open the top and bottom vanes insert the lip into the wall duct 3 Making sure that the back draught shutter is level mark the positions of the two fixing holes in the top right hand and bottom left hand corners 4 Remove the back draught from the wall duct 5 Drill screw holes in these positions ...

Page 7: ...ustable time delay DX100H only Manual mode use the on off switch When you switch off the fan goes into automatic mode after the time delay light indicates when fan is operating in manual mode Automatic mode fan operates when relative humidity rises and turns off again when humidity drops DX100PIR only The sensor detects movement in the room and activates the fan When movement is sensed the fan wil...

Page 8: ...Notes DX100 DX100PC DX100T DX100H DX100HP DX100PIR DX100VTD 54 ...

Page 9: ...55 ...

Page 10: ...nd service Customers outside UK see international below UK Xpelair have a comprehensive range of services including Free technical advice help desk from Engineers on all aspects of ventilation Free design service quotations and site surveys Service and maintenance contracts to suit all requirements Please ask for details By telephone on Techline 44 0 8709 000430 By fax on Techfax 44 0 8709 000530 ...